Features
The CONSLER AIL Series Air Intake Filters are designed for efficient air filtration with features such as low pressure drop, maximum filter area, and dirt holding capacity. They offer cleanable and replaceable filter elements, direct in-line mounting, and options for custom designs. These filters are suitable for remote or roof-mounted installations where easy access is needed.

Applications
The filters are ideal for removing dust, dirt, and airborne contaminants from inlet air streams, protecting air compressors, blowers, and engines in both indoor and outdoor settings. They are particularly useful in applications requiring long service life and adherence to original equipment manufacturer specifications.

Element Design and Construction
The AIL Series filters feature a pleated or radial fin cartridge design for maximum filter area and efficient filtration. They ensure positive gasket sealing to prevent unfiltered air bypass. The elements are available in various materials, including polyester, nylon, fiberglass, and more, with particle retention ranging from 0.3 to 750 microns.

Housing Design and Construction
The filter housings are made from heavy gauge sheet metal, designed for easy access and installation. They can be customized for specific applications, with options for different materials, connection types, and additional features.

Specifications
The document lists various models of the AIL Series, detailing their connection sizes, flow ratings, and dimensions. Standard filters are rated for 14.7 PSIA and come with a 10-micron polyester filter medium. The document also provides information on pressure drop and flow capacities.

Recovery and Maintenance
The filters are designed for easy maintenance, with options for cleaning and reconditioning. Graver Technologies offers a recovery service for sewn-end elements, allowing for extended use of the same filter element.

Additional Information
Graver Technologies, the manufacturer of Consler brand filters, provides a range of filtration products and services. They have representatives in major cities across the United States, Mexico, Canada, and other countries. For more information, customers are encouraged to contact their local representative or visit the company's website.
See more

Catalog excerpts

Low Pressure Gas Filters-1

Features • Low pressure drop-low energy loss • Maximum filter area and dirt holding capacity • Minimum "Down Time", long life • Cleanable, replaceable filter element • Direct mounting in-line to machinery • Modified and custom designs available • Optional non-ASME designs to 15 psig Applications • Remote or roof mounted air intake installations where easy access and convenient ground level filtration is desirable. • Efficient removal of dust, dirt, and other airborne contaminants from inlet air streams. Filtering of solid particles ranging from 0.3 to 750 microns. • Positive protection of air compressors, blowers and engines in indoor or outdoor service. Applications where long service life is essential. • Ideal for satisfying original equip. mfr. specs. Element Design and Construction The AIL Series filters offer a replaceable, cleanable element that incorporates a pleated or "radial fin" cartridge design. The element offers maximum filter area in a compact filter assembly, and provides positive gasket sealing to prevent by-pass of unfiltered air. Long filter life, low pressure drop, large dirt holding capacity and efficient filtration are assured. Element Materials Standard elements are furnished with a polyester filter medium providing nominal retention on 10 micron solid particles. AIL Series elements are also supplied in many alternate materials offering a particle retention range from 0.3 to 750 microns. Optional filter materials avaiIabIe include nylon, fiberglass, cotton, polypropylene, rayon, TEFLON1, and wirecloth. Standard elements are furnished with a carbon steel center core and epoxy coated steel support frame. Stainless steel and other materials are available. A cleanable plastisol molded-end element is provided as standard in models AIL 150-040 FL and smaller. Larger models are furnished with a cleanable, sewn-end constructed element, which can be reconditioned before replacement is necessary. Following several field cleanings this unique sewn constructed style element can be returned to the factory for recovery and reconditioning (see back page). Housing Design and Construction The totally enclosed AIL Series housings are designed for convenient, easy-access ground level use where a remotely piped, roof mounted, or other high level air intake is required. The AIL housings may be installed alongside/directly mounted to the air compression equipment and are well suited for both indoor or outdoor service. All models are fabricated from heavy gauge sheet metal. Horizontal inlet/outlet connections are offered to provide for simple installation, and all models may be serviced without disturbing piping connections. Standard filter housings may also be modified or customized to meet special application needs. Typical design modifications include: Special leg lengths, 304SS construction, end connection types, inlet/outlet orientations, cover lifting devices, and special controls and accessories. Housing Materials Standard materials are carbon steel and are furnished with a rust preventative primer coating beneath a durable allweather paint. Alternate materials including stainless steel are available. DuPont registered trademark.

 Open the catalog to page 1
Low Pressure Gas Filters-2

• Standard product is rated for 14.7 PSIA. • Models AIL 150 and up have two (2) cover handles. • Standard filters are supplied with a 10 micron polyester • Models A|L 150 and below have iridcted^nd elements. filter medium. See page 4 for options. • Models AIL 160 and up have sewn-end elements. • All flange connections have a plate flange with bolt holes • Models A|L 160 and up have three (3)leg supports, with drilledtomatchstd. 125#ANSIflange. length of 18"from bottom of vessel to grade.

 Open the catalog to page 2
Low Pressure Gas Filters-3

AIL Series Flow Capacities are based on actual test results or empirical calculations using standard 10 micron element. Contact your local representative or our sales engineering staff for sizing assistance. • Pressure drop for 24" connection size is for AIL 240-240 FL. Pressure Drop - Inches WC Air 14.7 PSIA @ 60° F Flow Rate (CFM) vs. Differential Pressure (inches WC) (filter models are represented by their standard connection size

 Open the catalog to page 3
Low Pressure Gas Filters-4

*Can only be used with a molded end element. Standard Molded End Style Elements STANDARD FEATURESAND BENEFITS (AIL 150 & SMALLER) • High-quality resilient blue plastisol end seals • Positive seal prevents bypass • Pleated polyester felt media provides maximum dirtholding capacity • Lifting lugs on large elements ease removal and installation • Other available media options offer 0.3 to 750 micron filtration • Stainless steel and other metal cores available Standard Sewn End Elements STANDARD FEATURESAND BENEFITS (AIL 160 & LARGER) • Polyester felt media for maximum dirt-holding capacity and excellent...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.