Group: GEA
Catalog excerpts
GEA Lyophil LYOPLUS™ Multipurpose measurement device for pharmaceutical freeze dryers LYOPLUS™ is a mass spectrometer that is fitted with advanced software enabling it to provide multiple process and equipment measurement data. The system is able to work alongside any existing PLC/SCADA system as a stand alone unit or fully integrated within the control system. It can also be operated independently as a monitoring system that does not interfere with any qualified processes. Silicone oil detection Top of the list of system benefits is its unique ability to detect very small traces of silicone oil within the dryer. Silicone oil is used to transfer the required heat energy to the product. After years of operation and many cycles the arduous conditions within the dryer could lead to small leaks. As a consequence oil can contaminate the final product. After the leak in the circulation system has reached a certain size this contamination will be detected during end product testing in quality control. That particular batch is of course lost but additionally suspicion immediately rises about the purity of previous batches. Using LYOPLUS™, however, it is possible to detect very small traces of silicone oil leaking within the dryer during the operating cycle. No additional batches are at risk as the leak would have been detected immediately. Moisture content The LYOPLUS™ system can also monitor moisture levels within the drying chamber during the drying cycle. At the beginning of the drying process the chamber will be filled with a saturated water vapour as water is removed rapidly from the product. During the later stages, however, the moisture level in the chamber reduces significantly. LYOPLUS™ measures this drop very accurately and correlates the measurement with the actual average product moisture inside the vials. This information can be used to refine drying recipes and avoid any unnecessary drying time. One of our customers has reported a three-hour saving per cycle providing improved productivity and a reduction in power consumption. An additional benefit comes from being able to predict the drying curve of the product through the moisture content in the chamber. Drying behaviour for each batch can be compared with a ‘qualified batch’ to confirm that the process is progressing normally. Technical data: Fully automated Fail-safe operation to protect sterility, the lyophilization equipment and the measurement device Standalone or optional full SCADA Implementation High performance quadrupole mass spectrometer system Mass range: 1-100 standard (1-200 AMU or 1-300 AMU optional) High conductance inlet system Max. operating pressure: 1 mbar Detection limit: 1ppm of non-interfering species engineering for a better world Chamber leak tests To prevent any contamination through a vacuum leak in the system, it is mandatory to perform a leak test after each critical process, i.e. after sterilization. This can take up to four hours, depending on the type of test performed, causing loss of productivity and consuming additional energy to create the necessary test conditions. By using LYOPLUS™ it is possible to reduce the time for this standard procedure down to approximately one hour owing to its very high sensitivity. If during the test a leak is detected it is necessary to perform a helium leak test to find the source of the leakage. Using standard external equipment for helium leak testing sometimes takes several hours to set up; LYOPLUS™ is permanently connected to the system so the helium leak test can begin instantly, detecting leaks much faster thereby savin
Open the catalog to page 1Contamination monitoring Drying endpoint verification Leak Check Operation PLC update required SCADA Audit trial, User log Batch report Data export Connection Tri Clamp or customer demand (<3d) Power supply Portable Online / History data trend view Batch Report preview GEA Pharma Systems – Lyophil™ GEA Lyophil GmbH Kalscheurener Straße 92, 50354 Hürth, Germany Phone: +49 (0) 2233 6999 0 lyophil@gea.com All copyrights reserved. Under no circumstances hould this document or any part of it be copied without GPS’s written consent. s Schematic system overview © GEA Pharma Systems 2012....
Open the catalog to page 2All Grasso International catalogs and technical brochures
-
GEA Hilge NOVALOBE
76 Pages
-
Batch Formula® Test Mixer
8 Pages
-
Containment Technology
20 Pages
-
GEA Granulation Technologies
32 Pages
-
The GEA Pharma Solids Center
20 Pages
-
GEA Screw Packages
20 Pages
-
GEA Blu Chillers
16 Pages
-
Process Automation Solutions
8 Pages
-
Omni control panel
12 Pages
-
Hygienic Valves and Components
278 Pages
-
LHP-NDC
2 Pages
-
LHP-DAD
2 Pages
-
Compression heat pumps
12 Pages
-
GEA screw compressors
8 Pages
-
GEA Grasso M Series
2 Pages
-
FES Motor Starter
2 Pages
-
FES Ammonia Dryer
2 Pages
-
FES Galaxy Series
2 Pages
-
GEA OmniTM control panel
12 Pages
-
Ammonia Dryer
2 Pages
-
Grasso DX R
4 Pages
-
GEA AWP product program
12 Pages
-
Bock HG Compressors - R410A
20 Pages
-
GEA Grasso Ammonia Dryer
2 Pages
-
GEA Bock Plusbox
8 Pages
-
GG Purger
5 Pages
-
Grasso BluAstrum
4 Pages
-
GEA Grasso chillers
12 Pages
-
GEA Grasso GSC
4 Pages
-
5HP Series
2 Pages
-
GEA Piston and Screw Compressors
12 Pages
-
Bock Compressor Units
44 Pages
-
Bock CO2 Verdichter
56 Pages
-
GEA Bock Open Type Compressors F
64 Pages
-
Bock ATEX Compressors
20 Pages
-
Catalogue Mobile Applications
100 Pages
-
HG HC
32 Pages
-
Grasso 12 Series
2 Pages
-
GM
2 Pages
-
5 HP
2 Pages
-
GEA Grasso 12E series
2 Pages
-
control devices
4 Pages
-
Sc series
12 Pages
-
Crasso reciprocating series
8 Pages
-
FX series
4 Pages
-
chillers
8 Pages
-
Grasso 6
2 Pages
Archived catalogs
-
GEA Grasso 5HP Series
16 Pages
-
Grasso Ammonia Dryer (GAD)
4 Pages