Refrigerated Circulating Baths
9Pages

{{requestButtons}}

Catalog excerpts

Refrigerated Circulating Baths - 1

2 Refrigerated / heating circulating baths and recirculating chillers Optima™ range Refrigerated circulating baths RC series Recirculating chillers

Open the catalog to page 1
Refrigerated Circulating Baths - 2

Refrigerated / heating circulating baths / recirculating chillers Refrigerated/heating circulating baths » Optima™ range Optima refrigerated / heating baths and circulators Cost-effective and efficient multi-purpose systems for low temperature applications. n n Powerful precision cooling whether used in open-loop or closed-loop format Combining legendary quality, reliability and design for everyday usage – useful features, straightforward maintenance, compact design n Robust, durable construction for longevity, reliability and long-term low cost of ownership n A comprehensive range – 18...

Open the catalog to page 2
Refrigerated Circulating Baths - 3

showcase – mid range example Model TC120-R2 range -25 to 100°C, stability ±0.1°C Our most popular model – a versatile system for the laboratory, with a comprehensive specification to suit most low temperature applications. n Optima™ digital thermostat (TC120) for precise temperature control n Cooling/heating range -25°C to 100°C n Stability ±0.1°C n Easy to use rotary dial and two function keys Also available as a kit (LTC2) see page 2.6 Clear 4 digit display – easy to read from a distance for instant reassurance Adjustable over temperature protection provides sample protection Visual alarm...

Open the catalog to page 3
Refrigerated Circulating Baths - 4

Factors to consider when choosing your system n Do you need to immerse samples within a tank? Consider the working area required. The table on p. 2.4 shows the dimensions of the top opening and the min/max liquid depths n Cooling power required at a given temperature For example, if your operating temperature is 0°C, and you need 500 W cooling power, you will need the R4 (or R5) refrigeration unit with any of the controllers. Alternatively to calculate the power required use the following formula: W= n Cool-down time required to reach that temperature W = average cooling power V = total...

Open the catalog to page 4
Refrigerated Circulating Baths - 5

Refrigerated / heating circulating baths – models, options and accessories Effective operating temperature range (refrigeration unit + thermostat) n 0°C to 100°C n -25°C to 100°C n -30°C to 100°C n -47°C to 100°C Key to symbols « display π timer Ë pump : USB/RS232 S drain 0 program storage fixed over temperature cutout q relay/ relay control N visual alarm % audible alarm 5 5 point re-calibration 3 menu system · external probe socket 2 programmable 2 2 point recalibration v refrigeration high pressure switch Ê adjustable over temperature cutout Thermostatic control units General purpose...

Open the catalog to page 5
Refrigerated Circulating Baths - 6

Refrigerated / heating circulating baths / recirculating chillers Refrigerated / heating circulating baths » Technical specifications Low temperature refrigerated baths and circulators – technical specification Grant Optima™ thermostats General purpose digital Advanced digital Setting resolution full colour QVGA TFT 1 min to 99 hrs 59 mins Timer function No. stored temperature values Re-calibration points Socket for external probe (TXPEP, TXSEP) Communications interface remote via PC / laptop via user interface/remote via PC / laptop 1 program/30segments 10 programs/100segments over...

Open the catalog to page 6
Refrigerated Circulating Baths - 7

Pump connectors (optional) Part number Replacement plastic pump inlet/outlet connector. Fits tubing 9mm inner dia. Temp range -50˚C to 200˚C Replacement plastic pump inlet/outlet connector. Fits tubing 15mm inner dia. Temp range -50˚C to 200˚C Stainless steel pump inlet/outlet connector, M16 x 1 male. Fits M16 hose. Temp range -50˚C to 200˚C Metal pump inlet/outlet connector, dual seal super rapid 4mm. Fits semi rigid tubing 4mm outer dia. Temp range -20˚C to 100˚C Metal pump inlet/outlet connector, dual seal super rapid 6mm. Fits semi rigid tubing 6mm outer dia. Temp range -20˚C to 100˚C...

Open the catalog to page 7
Refrigerated Circulating Baths - 8

Refrigerated / heating circulating baths / recirculating chillers Refrigerated / heating circulating baths » Recirculating chillers » RC series Recirculating chillers RC series Comprehensive range of robust re-circulating chillers delivering a constant flow of temperature-controlled liquid to provide powerful, regulated cooling at -10ºC for many types of industrial machinery and scientific apparatus. Suitable for circulation through open and closed systems. n Temperature range -10ºC to 60ºC or -5ºC to 60ºC (model dependent) n Stability ±0.25ºC or ±0.5ºC (model dependent) n Choice of models...

Open the catalog to page 8
Refrigerated Circulating Baths - 9

Products for special low temperature applications – models and specifications ● Re-circulating chillers – digital control Temperature range Display resolution Typical cooling power, ambient 20°C @ 20°C Heater power Overall consumption Pump head pressure @ 1 L/min Pipe connection, inlet/outlet Liquid flow rate, maximum Reservoir capacity Safety: – temperature switchable undertemperature thermostat – temperature fixed over temperature cut-out – level Refrigerated / heating circulating baths / recirculating chillers Refrigerated / heating circulating baths » Recirculating chillers » Models and...

Open the catalog to page 9