Product catalog summary
Product Identification: This document is a Safety Data Sheet for ISO Pump Oil, a lubricant and gear lubricant, identified by product codes 217374, 218656, and 204559, supplied by Graco BVBA, Belgium.
Hazards Identification: The product is not classified as hazardous under Regulation (EC) No. 1272/2008, with no noted adverse effects on physicochemical properties, human health, or the environment.
Composition: The mixture contains over 85% white mineral oil (petroleum), noted for aspiration toxicity under Regulation (EC) No. 1272/2008.
First Aid Measures: Inhalation may cause respiratory irritation; skin and eye contact may cause irritation. Ingestion can irritate the digestive tract. Seek medical attention if symptoms persist.
Firefighting Measures: Use carbon dioxide, water, or dry chemical powder to extinguish fires. Toxic gases may be released during a fire.
Accidental Release Measures: Use personal protective equipment. Contain and clean spills to prevent environmental contamination.
Handling and Storage: Store in a cool, dry, well-ventilated area away from ignition sources. Handle containers carefully to avoid exposure to flames or sparks.
Exposure Controls/Personal Protection: Use protective goggles and gloves. There are specific exposure limits for oil mist in various countries.
Physical and Chemical Properties: The product is a light amber liquid with a mild sulfur odor, a flash point of 190°C, and a kinematic viscosity of 449.5 cSt at 40°C.
Stability and Reactivity: Stable under normal conditions but should be kept away from strong oxidizing agents.
Toxicological Information: Not classified as acutely toxic, but inhalation of vapors may cause respiratory irritation.
Ecological Information: Not readily biodegradable, floats on water, and does not meet PBT or vPvB criteria.
Disposal Considerations: Dispose through incineration or recycling at an appropriate facility. Do not reuse containers without proper cleaning.
Transport Information: Not regulated for transport under ADR, RID, IMDG, IATA, or ADN.
Regulatory Information: Listed on various international chemical inventories and classified as slightly hazardous to water in Germany.
Other Information: Information is based on current knowledge for health, safety, and environmental purposes and does not guarantee specific product properties.
See more

Catalog excerpts

SDSIPOENEU-A ISO Pump Oil Safety Data Sheet-1

Safety Data Sheet according to Regulation (EC) No. 453/2010 ENEU Revision date: 19/12/2014 GR/VCO RGV. A SECTION 1: Identification of the substance/mixture and of the company/undertaking Product form Product name Product code Relevant identified uses of the substance or mixture and uses advised against 1.2.1. Relevant identified uses Gear Lubricant 1.2.2. Uses advised against No additional information available 1.3. Details of the supplier of the safety data sheet Graco BVBA Industrieterrein Ounde Bunders Maasmechelen - Belgium 1.4. Emergency telephone number Emergency number SECTION 2: Hazards identification Classification of the substance or mixture Classification according to Regulation (EC) No. 1272/2008 [CLP] Classification according to Directive 67/548/EEC [DSD] or 1999/45/EC [DPD] Adverse physicochemical, human health and environmental effects No additional information available Label elements Labelling according to Regulation (EC) No. 1272/2008 [CLP] No additional information available SECTION 3: Composition/information on ingredients Full text of R- and H-phrases: see section 16

 Open the catalog to page 1
SDSIPOENEU-A ISO Pump Oil Safety Data Sheet-2

ISO Pump Oil Safety Data Sheet SECTION 4: First aid measures 4.1. Description of first aid measures First-aid measures after inhalation : Remove to fresh air and keep at rest in a position comfortable for breathing. If you feel unwell, seek medical attention. First-aid measures after skin contact : Wash contaminated clothing before reuse. Take off immediately all contaminated clothing. Wash with plenty of soap and water. First-aid measures after eye contact : Rinse immediately with plenty of water for 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. First-aid measures...

 Open the catalog to page 2
SDSIPOENEU-A ISO Pump Oil Safety Data Sheet-3

ISO Pump Oil Safety Data Sheet SECTION 7: Handling and storage 7.1. Precautions for safe handling Precautions for safe handling : Do not pressurize, cut, weld, braze, solder, drill, grind, or expose containers to flames, sparks, heat, or other potential ignition sources. Keep container closed when not in use. Open and handle container with care. Ensure adequate ventilation. Hygiene measures : Do not eat, drink or smoke when using this product. Wash contaminated clothing before reuse. Take care for general good hygiene and housekeeping. Conditions for safe storage, including any incompatibilities...

 Open the catalog to page 3
SDSIPOENEU-A ISO Pump Oil Safety Data Sheet-4

ISO Pump Oil Safety Data Sheet Viscosity, kinematic Viscosity, dynamic Explosive properties Oxidising properties Explosive limits Other information No additional information available SECTION 10: Stability and reactivity 10.1. Stable under normal conditions. 10.2. Chemical stability Stable under normal conditions. 10.3. Possibility of hazardous reactions Hazardous polymerization will not occur. 10.4. Keep away from open flames, hot surfaces and sources of ignition. 10.5. Incompatible materials Oxidizing agents, strong. 10.6. Hazardous decomposition products On incomplete combustion releases :...

 Open the catalog to page 4
SDSIPOENEU-A ISO Pump Oil Safety Data Sheet-5

ISO Pump Oil Safety Data Sheet ISO Pump Oil Ecology - soil 12.5. Results of PBT and vPvB assessment Component White mineral oil (petroleum)- (8042-47-5) 12.6. This substance/mixture does not meet the PBT criteria of REACH regulation, annex XIII This substance/mixture does not meet the vPvB criteria of REACH regulation, annex XIII Other adverse effects No additional information available SECTION 13: Disposal considerations 13.1. Waste treatment methods Waste treatment methods : Dispose of contents/container to industrial incineration plant. Sewage disposal recommendations : Prevent entry to sewers...

 Open the catalog to page 5
SDSIPOENEU-A ISO Pump Oil Safety Data Sheet-6

ISO Pump Oil Safety Data Sheet Special precautions for user Overland transport Inland waterway transport Rail transport Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code SECTION 15: Regulatory information 15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture No REACH Annex XVII restrictions Contains no substance on the REACH candidate list 15.1.2. National regulations Listed on the AICS (Australian Inventory of Chemical Substances) Listed on the Canadian DSL (Domestic Sustances List) Listed on IECSC (Inventory of Existing Chemical...

 Open the catalog to page 6

All GRACO catalogs and technical brochures

  1. Supply Pumps

    8  Pages

  2. Triton™

    8  Pages

  3. Fusion® CS

    6  Pages

  4. FRP Systems

    16  Pages

  5. SaniSpray HP™

    20  Pages

  6. PFP Sprayers

    8  Pages

  7. Reactor

    20  Pages

  8. FUSION™

    24  Pages

  9. T-MAX™

    3  Pages

  10. SDV15

    12  Pages

  11. G3 Max

    4  Pages

  12. G1 Standard

    26  Pages

  13. G1 Plus

    34  Pages

  14. M2K

    3  Pages

  15. InvisiPac

    8  Pages

  16. AirPro Brochure

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.