MAVOWATT 210 - 1

MAVOWATT 210 Three-Phase Power and Energy Logger • Accurate, three-phase, bidirectional power and energy logger to identify and record common PQ issues • Portable, small and compact • 3+1 voltage and 4 current channels • 4 voltage leads and 3 flexible AC Rogowski current probes • Suitable for monitoring single, two, and three phase applications • Ethernet and USB • Integrated web server for easy configuration and real time data monitoring • Dran-View XP software • Softcase Various local or remote power monitoring applications: • 3+1 voltage channels − Direct measurements up to 600 VRMS, CAT III • 4 current channels − MAVOWATT 210 Rogowski or hinged CTs (see Optional Accessories) • Measures: V, I, W (P), VA (S), VAR (Q), PF, demand, energy & much more • PQ disturbance detector − Detects and records trends of RMS sags/dips, swells, current changes (IEC 610004-30 1/2 cycle methods) • Harmonic measurements & recording − Vthd, Ithd. Measurements according to IEEE 519-2014/ IEC 61000-4-7 • Integrated web browser for setup, real time metering, and data transfer • Dran-View XP software for analysis and reporting • 7 hours battery runtime • Automatic wiring verification − LEDs indicate wiring errors • Ethernet and USB communications • Modbus, BACnet® Energy audits according to DIN EN 16247-1 Demand side management Basic PQ surveys Check metering Sub metering Tenant metering Alternative energy production Energy cost allocation Load profiling Power factor studies Residential appli

Open the catalog to page 1
MAVOWATT 210 - 2

Technical Data Relevant Standards Mechanical Design Housing (W x H x D): Weight: Protection: Approx. 6.4 x 8.9 x 18.8 cm Approx. 0.64 kg IP50 (in vertical position) The instrument has been manufactured and tested in accordance with the following safety regulations: Ambient Conditions EN 61326 Class A, Electromagnetic Compatibility -Electrical equipment for Measurement, Control and Laboratory use CISPR 11 Class A Limits Of Radio Disturbance and Immunity Measuring Apparatus temperature: Elevation: max. 2000 m above sea level Power Supply AC Power Supply Electrostatic Discharge Immunity...

Open the catalog to page 2
MAVOWATT 210 - 3

Frequency Range Energy (True/Active) energy (P) 0.1% Parameters Reactive energy (Q) 0.1% energy (P) Fundamental reactive 0.2% energy (Q) Fundamental apparent 0.2% Power Active power (P) 0.2% Parameters Reactive power (Q) 0.2% power (P) Fundamental reactive 0.2% power (Q) Fundamental apparent 0.2% power (S) Power factor ±0.001% 1 Flexible AC current probe based on the Rogowski principle, 50 - 500 A, measuring head length 40 cm (product no. Z840A) 1 Flexible AC current probe based on the Rogowski principle, 150 - 1500 A, measuring head length 40 cm (product no. Z840B) 1 Flexible AC current...

Open the catalog to page 3

All GOSSEN METRAWATT GmbH catalogs and technical brochures

  1. METRAOHM 10

    3 Pages

  2. ENERGY METER

    4 Pages