video corpo

INTG8

INTG8

INTG8

Product catalog summary
Specifications
The INTG8 Series pumps operate at a maximum system pressure of 75 psi and weigh approximately 3.5 lbs (1596.645 grams). They feature 1.25” MHB ports and are powered by an integrated, brushless DC motor. The pumps can be controlled via direct supply voltage, analog (0-5v DC signal), digital (PWM), CAN-Bus, or a tachometer feedback option. The supply voltage ranges from 12-48 VDC, with a maximum power of 600 Watts. It is crucial to use the recommended fuse size based on the voltage supplied to protect the control board.
Performance
The maximum flow rates and total head vary with voltage: at 48/36 VDC, the flow is 39.29 GPM (148.74 L) with a total head of 13.84 Ft (6.00 PSI, 0.41 BAR, 4.22 M). At 12 VDC, the flow is 21.97 GPM (83.17 L) with a total head of 4.07 Ft (1.76 PSI, 0.12 BAR, 1.24 M). Testing was conducted in a controlled environment, and actual performance may vary by ±10%.
Operational Guidelines
Pumps must not run dry and should be in a continuous flooded suction environment. The maximum fluid temperature rating is 225°F (107°C) when the controller is separate from the pump. Various factors such as starting fluid temperature, ambient temperature, and required performance influence the maximum temperature rating.
Materials
The pump body, housing, and impeller are made of PPS, the static O-ring is available in EPDM or FKM, and the pump shaft is ceramic.
Compliance and Approvals
Many GRI pumps comply with RoHS and REACH standards. For specific model compliance, contact GRI.
See more

Catalog excerpts

INTG8-1

GRIpumps.com PUMPS A GORMAN-RUPP COMPANY Motor: Integrated, Brushless DC Supply Voltage: 12-48 VDC Electronics Maximum Power: 600 Watts To protect the control board, each Integrity Series pump will be issued with a Maximum Power limit (Watts). To stay within this limit, the recommended fuse size (Amps) will be based on the voltage supplied. (Watts = Voltage X Amps) Control Options • Direct Supply Voltage: Speed of the pump determined by the voltage supplied • Analog: 0-5v DC signal • Digital: PWM • CAN-Bus: Option available • Tachometer: Feedback option available Controller Position Maximum Fluid Temp Rating Separate from pump 225°F (107°C) Within pump's housing Not Applicable Various factors influence the recommended maximum temperature rating. These factors play a role in determining the pump’s life and applied warranties. In some applications, a higher maximum fluid temperature rating may be warranted. Factors influencing maximum temperature rating include, but are not limited to: • Starting temperature of fluid in system • Ambient temperature • Required performance, application’s specifications • Run time Note: Testing performed in a controlled laboratory environment. Actual performance may vary (+) or (-) 10% from the information shown. Do Not Run Pumps Dry. Pumps must be in a continuous flooded suction environment. Available Agency Approvals | Contact GRI RoHS/REACH Many GRI pumps are RoHS & REACH compliant. For declarations by specific model numbers, please contact GRI. 180 Hines Ave. • Bellville, OH 44813 • PH: 419-886-3001 • FAX: 419-886-2338 • www.GRIpumps.c

 Open the catalog to page 1
INTG8-2

INTG8 Series Typical Dimensional Drawing. OEM options are available. Please contact GRI to discuss. 180 Hines Ave. • Bellville, OH 44813 • PH: 419-886-3001 • FAX: 419-886-2338 • www.GRIpumps.com 13

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.