1. Catalogs
  2. GORGY TIMING
  3. LEDI® NETWORK ITS v2m 2U

LEDI® NETWORK ITS v2m 2U

LEDI® NETWORK ITS v2m 2U

LEDI® NETWORK ITS v2m 2U

Product catalog summary
Internal Time Base
The device includes a battery and oscillator to maintain stable time code output during synchronization or power failures. It offers three quartz oscillator options: OCXO LN, OCXO, and TCXO, each with varying frequency stability and aging characteristics.
Security
Default backup power is included, with an option for extended capacity. Configuration settings are stored in flash memory. Security features include 64-bit RSA™ MD5 signature and HTTPS, with supervision possible via SNMP software (Version 3).
Network Protocols
Supports NTP (v2, v3, v4), SNTP (v4), HTTPS, SNMP (v1, v2c, v3), IPv4/IPv6, FTP, SYSLOG, and PTPv2 IEEE 1588.
Specifications
Power supply is 115-230 VAC/50-60Hz, with certifications including CE, EN 60950, EN 55022, and EN 55024. Maximum consumption is 20 VA, with an IP rating of 31. The device has an MTBF of 110,000 hours and MTTR of 5-10 minutes depending on the board. It weighs 2.3 kg and fits a 19’’ 2U rack.
Key Features
Includes power supply redundancy, configurable synchronization input priorities, and compensation for input delay. It ensures output accuracy up to 50ns when synchronized to GNSS. Offers multiple synchronization outputs and alarm management via SNMP TRAP.
Configuration
Remote configuration and time setting are available via a web interface with secured HTTPS connection. Time zone and daylight saving adjustments are automatic. Supervision information is accessible via HTTP/HTTPS, SNMPv3, and Telnet.
Synchronization Inputs
First input options include GNSS multi-constellation receiver and ASCII (NMEA 0183). Second input options include AFNOR NFS 87500/IRIG B and NTPv4. A third backup input is available for PPS or frequency input.
Synchronization Outputs
Includes an SDHC memory card for the main NTP output and multiple output options such as AFNOR NFS 87500/IRIGB, ASCII RS232/RS485, PTPv2 IEEE 1588, and NTP V4/SNTP server outputs.
GNSS Antenna
For detailed specifications, refer to the GNSS elements technical specifications.
See more

Catalog excerpts

LEDI® NETWORK ITS v2m 2U-1

LEDI® NETWORK ITS v2m 2U High Accuracy secure time Server with triple synchronization redundant inputs and with multiple synchronization outputs. Key features Internal time base Its incorporated battery and its oscillator allow to provide stable time code output in case of synchronization or power supply failure. Three quartz oscillators at choice : • OCXO LN: High frequency stability 5.10-10 (-10°C to 60°C). Low ageing 3.10-10 / day. • OCXO: High frequency stability 1.10-9 (-20°C to 70°C). Low ageing 5.10-10 / day. • TCXO: Frequency stability 1.10-6 (0°C to 60°C). Ageing 2.10-9 / day. Security Back up power is included by default. Possibility of extended back up power capacity with Option J. The duration of power reserve will depend on the configuration of the time server, please contact our sales team for more details. Backup configuration settings in flash memory. High level of security: 64 bits RSA™ MD5 signature, HTTPS. Supervision possible via SNMP software (Version 3). Network Protocols • • • • • • • • • NTP (v2, v3, v4) NTP Client/Server, Broadcast, Multicast SNTP (v4) HTTPS SNMP (v1, v2c, v3) IPv4 / IPv6. (DHCP v4 / v6 compatible) FTP SYSLOG PTPv2 IEEE 1588 Configuration Remote configuration and time setting via web interface. (secured connexion via HTTPS available) Time zone configuration. Automatic adjustment of Daylight saving. Supervision Information available via HTTP/ HTTPS, SNMPv3, Telnet, “GT Network Manager”, “GT Ethernet Supervision”. Time and synchronisation status is available on the alphanumerical front display. Operating on Windows NT/XP/2000/2003/Vista (32 bits)/ Windows7 Firmware update via FTP. 1 NTP output (RJ45) is included in the basic configuration. ® Synchronization Inputs • Specifications 18-36 VDC 36-72 VDC CE, EN 60950 (safety), EN 55022 (EMC transmission), EN 55024 (EMC immunity) 20 VA (depending on selected configuration) 31 Power Supply 115-230 VAC/50-60Hz Certifications Max. consumption IP Power Supply Redundancy 18-36 or 36-72 VDC with 115-230 VAC. Configurable priorities of synchronization inputs. Compensation of input delay due to transmission distance and threshold setting for security. Time Base and algorithm ensuring output accuracy up to 50ns when synchronized to GNSS. Multiple synchronization outputs of different types de time code. Time can be configured individually on each output, via DST and Offset. PPS and 10Mhz output (available with OCXO oscillator only) via BNC connectors. Alarm management via SNMP TRAP and two static relay outputs on screw terminal for synchronization and power supply alarms. Manual or automatic adjustment for transmission delay. System Event Journal. Operational within 1 minute. Local or UTC time on the digital display. MTBF 110 000 h. Mother board : 10 min. MTTR Display board : 5 min. Output board : 5 min. Weight 2.3 Kg (Standard configuration) 1st time reference input - choice amongst: • Multi-constellation GNSS Receiver: (GPS, GLONASS, BEIDOU, GALILEO) Cold start, accuracy from 10 to 50 ns). • ASCII (NMEA 0183). 2nd time reference input - choice amongst: • AFNOR NFS 87500/IRIG B/ IEEE1344. • NTPv4 Ethernet 10/100BaseT (RJ45 connector). 3rd reference input (backup): • PPS input • Frequency input (from 1Khz to 10Mhz). Synchronization Outputs • • Comes with 1 SDHC memory card for main NTP output Multiple outputs (see overleaf). GNSS Antenna (refer to the GNSS elements) • For more information on our GNSS antennas, refer to the technical specifications. Dimensions 19’’ 2U Rack. 482x88x266 mm (LxHxT) Display 4 x 20 orange OLED screen with backlight. Operating temperature -10° to 50°C Storage temperature -20° to 70°C Maximum operating / 3 500 m (11 483 ft) storage altitude

 Open the catalog to page 1
LEDI® NETWORK ITS v2m 2U-2

ITEM CODE LEDI NETWORK ITS v2m 2U 1st SYNCHRONIZATION INPUT* GNSS multiconstellation (GPS, GLONASS, BEIDOU, GALILEO)* GPS Receiver (antenna and cable not included)* NMEA + TOP TOP (PPS) none *Antenna and cable to be ordered separately 2nd SYNCHRONIZATION INPUT AFNOR NFS 87500/IRIG B (Modulated 1Kz) AFNOR NFS 87500/IRIG B DCLS NTP None 3rd SYNCHRONIZATION INPUT None External frequency input 10MHz** **Frequency Input: available with OCXO oscillator only, 1 other required entry. OSCILLATOR TCXO, 1PPS output (BNC) OCXO, PPS and 10MHz output modulated (BNC) OCXO LN, PPS and 10MHz output modulated...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.