Catalog excerpts
|| 1st Floor, Bldg No.4, No.555 Dongchuan Rd MinhangDist, Shanghai, 200241 China Distributed Fieldbus I/O System iMetal Fieldbus Connector
Open the catalog to page 1Fieldbus Connector Fieldbus Cable 46-52 It is a great impact on modern automation system that more and more real-time Fieldbus technology, and centralized control equipment are replaced by distributed intelligent devices. Signal attenuation often occurs during long-distance data transmission, long distance transmission also causing signal interference. Distributed I/O system is a good solution for long distance communication. Thanks to modularized design and multiple communication protocols, Softlink iModule series remote I/O has great advantages, which is easy to use, smart and...
Open the catalog to page 3O Compact design, vibration resistance O Spring terminals,get reliable connection o Two layers terminals, saving wiring space o Unique design of the internal power supply O Decimal button, flexible switching from 0-99 stations O Up to 32 channels for data communication iModule series Fieldbus I/O integrated communication ports, power module, I/O module all in one, compact design and space-saving. It is widely used in various applications for stable and high cost performance. Compact design in one unit Unified shell dimension : 155*105*55mm ( W/H/D ) Installation : standard DIN rail...
Open the catalog to page 4The real-time EtherCAT technology, widely used in machines and motion control applications. Outstanding performance, flexible topology and simple configuration characterise EtherCAT , the real-time Ethernet technology, which is the expansion of IEEE 802.3 as part of IEC 61158. EtherCAT sets new standards where conventional fieldbus systems reach their limits: 1,000 distributed I/Os in 30 µs, almost unlimited network size, EtherCAT I/O and optimum vertical integration thanks to Ethernet and internet technologies. With EtherCAT, the costly Ethernet star topology can be replaced with a simple...
Open the catalog to page 5Product Description Product Description Digital 16 Input /16 OutputMosfet Digital 32 Output (Mosfet Digital 16 Input /16 OutputRelay Digital Input Module Digital Output Module Input filter Nominal Input Voltage Digital Input Port protect Impact over Voltage protection Impact over Voltage protection Impact over Output type Nominal output voltage Open drain output 24 V DC(-15%/+20%) Open drain output Dry contact short circuit Dry contact open circuit Short circuit current(per Ch.) - Voltage protection Digital Output Number of outputs Port protect Overvoltage & overcurrent Total error Output...
Open the catalog to page 6Product Description Digital 8 Input/8 OutputMosfet Analog 8 Input/4 Output Mixed Signal I/O Module Mixed Signal I/O Module Input filter Nominal input voltage Port protect Impact over voltage protection Impact over voltage protection Output Type Nominal input voltage Open drain output Open drain output Digital Input Digital Output Short circuit current(per Ch.) 1A Port protect overvoltage & overcurrent protection overvoltage & overcurrent protection Analog Input Number of inputs Signal Type Single-ended Voltage Single-ended Current Input impedance Total error Conversion rate Analog Output...
Open the catalog to page 7CANopen is an upper-layer communication protocol based on Controller Area Network, being one of the popular modern industry Fieldbus, drafted and developed by non-profit organization CiA (CAN in Automaion). The CiA drafts standard 301 definition basic CANopen equipment and sub-agreement. The sub-agreements of individual devices are further expansion based on CiA 301, such as CiA401 for I / O modules and CiA402 for motion control. CANopen adopts two-wire serial communication, and allows up to 127 devices in a CANopen network. The maximum transfer rate is 1Mbps / 40 meters, and the maximum...
Open the catalog to page 8Product Description Product Description Digital 16 Input/16 Output Mosfet Digital 32 Output Mosfet Digital 16 Input/16 Output Relay Digital Input Module Digital Output Module Digital I/OModule Digital Input Digital Input Input filter Input filter Nominal input voltage Nominal input voltage Port protect Impact over voltage protection Port protect Impact over voltage protection Impact over voltage protection Digital Output Digital Output Output Type Output Type Nominal input voltage Nominal input voltage Open drain output Open drain output Dry contact short circuit Dry contact open circuit...
Open the catalog to page 9Product Description Digital 8 Input/8 Output Mosfet4thermal resistance Mixed Signal I/O Module Temperature module Input filter Nominal input voltage Port protect Impact over voltage protection Impact over voltage protection Output Type Nominal input voltage Open drain output Open drain output Digital Input Digital Output Short circuit current(per Ch.) 1A Port protect overvoltage & overcurrent protection overvoltage & overcurrent protection Signal Type Input impedance Total error Conversion rate Software filter 50/60Hz filter, break wire instructions Analog Input Analog Output Output Range
Open the catalog to page 10Product Description Digital 8 Input/8 Output Mosfet4 thermocouple Temperature module Temperature module Temperature module Input filter Nominal input voltage Port protect Impact over voltage protection - Output Type Nominal input voltage Open drain output Short circuit current(per Ch.) Port protect Overvoltage & overcurrent protection Digital Input Digital Output Output error Output settling time Voltage supply Electrical isolation (Bus/Field potential) AC 500V Transmission rate Address config Communication Profile Device Profile Device monitor Heartbeat, Node Guarding Heartbeat, Node...
Open the catalog to page 11Transmission rate Address config Communication Profile Device Profile Device monitor Heartbeat, Node Guarding Heartbeat, Node Guarding Transmission rate Address config Communication Profile Device Profile Device monitor Heartbeat, Node Guarding
Open the catalog to page 12Profibus is also a popular modern industry Fieldbus developed on RS485, according to the ISO / OSI reference model standard, becoming a German standard when published in DIN19245 in April 1991. With the maximum transfer rate of 12Mbps / 100 meters and the maximum transmission distance of 1200 meters /9.6kbps, the Profibus network's size up to 126 nodes, the network length 100-1200m. Profibus I/O iModule series of Profibus I/O enables fast connection to Profibus bus network, via acquiring signals and communicating with the master station, to complete a reliable control of fieldbus devices.
Open the catalog to page 13All Googol Technology (HK) Limited catalogs and technical brochures
-
GMPPC-1201-BT0001
4 Pages
-
XYZ Stage
3 Pages
-
XY Table
3 Pages
-
Self-Balancing Robot
2 Pages
-
SCARA Robotic Arm
4 Pages
-
Magnetic Levtitaiton System
2 Pages
-
Linear Inverted Pendulum
3 Pages
-
Four-Rotor Hover Vehicle
3 Pages
-
DC Servo Control Trainer
3 Pages
-
6DOF Robotic Arm
2 Pages
-
3DOF Helicopter Simulator
2 Pages
-
CB10L
2 Pages
-
EC-B01_Robot Controller
1 Pages
-
EC-C01_Robot Controller
1 Pages
-
iDEABOX 3 CPU
6 Pages
-
Fieldbus Cables
2 Pages
-
Fieldbus Connectors
4 Pages
-
Modbus I/O Modules
5 Pages
-
Profinet I/O Modules
6 Pages
-
CANopen I/O Modules
8 Pages
-
EtherCAT I/O Modules
6 Pages
-
Profibus – DP I/O Modules
10 Pages
-
GTDD Servo Drive
2 Pages
-
GTHD Servo Drive
2 Pages
-
Motion Control Panel PC
4 Pages
-
GE Series Motion Controllers
13 Pages
-
Ball & Beam control system
3 Pages
-
GUS Series motion controller
2 Pages
-
GT Series Motion Controllers
13 Pages
-
Softlink 300 PLC System
18 Pages
-
Educational Products
48 Pages