SPfCIAl HPt THIRMOMETIR • SRG Series - Surface Type Temperature Gauge Liquid, Gas Filled Available Optional Type: • SRG-QS: Surface mount sensor bulb c/w every angle connection • SRG-W: Surface mount sensor bulb c/w capillary & wall mounting flange • SRG-P: Surface mount sensor bulb c/w capillary & panel mounting flange Dial Size: 0100,0150mm available Case & Cover Material: SS304 or SS316 available Lens: Glass, Safety glass available Sensor Bulb Capillary Tube, Flex Tube Material: SS304 Capillary Tube Length Limited: Liquid filled type: 10M Gas filled type: max. 50M; option available Housing Enclosure: IP66, liquid filled available Range Limit: -200°C to +650°C available Stem Dimensions: 010,12mm; option on request Stem Length Limit: Standard lOOmm(H); option on request Sensor Bulb Length: Standard 120mm(L); option on request Over Range Protection: 130% F.S. Switch Form: Limit Switch: available 7 functions for usage Micro Switch: One setting point SPDT x 1 or Two setting points SPDT x Switch Data: Please see the Contact Type Assemblies Table 0iJan2023 WWW.NEW-FLOW.COM • TEL: 886-7-8135500 • FAX: 886-7-8225588 • Email: [email protected] H*: Length option on request.
Open the catalog to page 1Surface Mount Sensor Bulb c/w Capillary & Wall Mounting Flange Fitting Hole Capillary- PIPE- OPTIONAL: Limit Switch or Micro Switch available. Dimensions Data H*: Length option on request. Remote Capillary Length: max. 50M
Open the catalog to page 2Contact Type Limit Switch (Piatinum Contact) Assembiies Limit Switch Contact Rating CONTACT MODE 0iJan2023 W WWW.NEW-FLOW.COM • TEL: 886-7-8135500 • FAX: 886-7-8225588 • Email: [email protected]
Open the catalog to page 3Contact Type “Micro Switch” Assemblies Micro Switch Contact Rating Nominal Operating Voltage Mounting Instructions LIQUID FILLED TYPE
Open the catalog to page 4Ordering Information SRG Code Type QS Surface Mount Sensor Bulb c/w Every Angle Connection Surface Mount Sensor Bulb c/w Capillary & Wall Mounting Flange Surface Mount Sensor Bulb c/w Capillary & Pipe Mounting Flange Code Dial Size 0lOOmm 6 0150mm Code Case 8i Cover Material ouan2023 WWW.NEW-FLOW.COM • TEL: 886-7-8135500 • FAX: 886-7-8225588 • Email: [email protected] SS304 SS316 Code Lens Material Glass Safety Glass Code Capillary Length Without Please fill in the request length, (e.g. 3M) Code Stem Diameter (1)010 (2)012 (3) Option Code Stem Length (H) Standard lOOmmH Please fill in the request...
Open the catalog to page 5• SHG Series - Hybrid Type Temperature Gauge Technical Data Thermometer Type: Available for Bi-Metal Thermometer, or Liquid & Gases Filled Type Thermometer Case & Cover Material: SS304 or SS316 available Stem Material: SS316 Lens: Glass, Safety glass available Housing Enclosure: IP66, liquid filled available Dial Size: 075,0100,0125mm available for Bi-Metal Thermometer; 0100,0150 available for Filled Type Thermometer Range Limit: -50°C to 600°C Stem Dimensions: 04 or 06 mm available Stem Length Limit: 65~1000 mm; option available Zero Adjustable: External (for Bi-Metal Thermometer) Process Connection:...
Open the catalog to page 6ouan2023 ^ WWW.NEW-FLOW.COM • TEL: 886-7-8135500 • FAX: 886-7-8225588 • Email: [email protected] Model: SHG-SH_-QS Every Angle Connection Type Model: SHG-SH_ Bottom Connection Type
Open the catalog to page 7Connection Type T: Process connection F: Hexagonal head i\ Sensor length d: Sensor dimension WWW.NEW-FLOW.COM • TEL: 886-7-8135500 • FAX: 886-7-8225588 • Email: [email protected] 1 For Type of Bl-Metal Thermometer: For Type of Gas Filled Thermometer: Minimum Stem Length 1. Please note the min. insertion length is not including the thread. 2. Special Range / Scale / Stem Diameter / Length are available upon request.
Open the catalog to page 8ouan2023 WWW.NEW-FLOW.COM • TEL: 886-7-8135500 • FAX: 886-7-8225588 • Email: [email protected] Assembly Confinguration for Enclosure Head & Ouput1. Enclosure Head: •Protection: Weather Proof Approval Explosion Proof Approval SS316 or Aluminum alloy available Please refer to our catalogue of Thermocouple and RTD Assemblies. •Thermocouple: N, K, E, J, T type available •Element No.: Single or Dual elements •Terminal Blocks: Mounts to enclsoure head with two screws. •Reference: Please refer to our catlaogue of Thermocouple and RTD Assemblies. 4~20mA (2-wires), linear with respect to the measured...
Open the catalog to page 9Ordering Information1. THERMOMETER MODEL: SHG Code Model Type Code Case & Cover Material Sensor Diameter Electrical Output Head Housing Weather Proof: (1) HN (2) HP (3) HD (4) HI (5) HB (6) LS (7) option Sheath Material (A) SS316 (0) Option Sensor Class Transmitter Electrical Output
Open the catalog to page 102 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
2 Pages
10 Pages
3 Pages
2 Pages
2 Pages
4 Pages
2 Pages
1 Page
1 Page
3 Pages
4 Pages
1 Page
6 Pages
1 Page
1 Page
1 Page
1 Page
2 Pages
3 Pages
4 Pages
1 Page
1 Page
1 Page
1 Page
4 Pages
2 Pages
1 Page
3 Pages
3 Pages
2 Pages
2 Pages
3 Pages
4 Pages
1 Page
1 Page
3 Pages
11 Pages
1 Page
2 Pages
1 Page
2 Pages
4 Pages
2 Pages
2 Pages
3 Pages
2 Pages
1 Page
1 Page
1 Page
3 Pages
2 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
4 Pages
2 Pages
1 Page
1 Page
3 Pages
3 Pages
3 Pages
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
4 Pages
3 Pages
1 Page
5 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
1 Page
1 Page
3 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages