PGC Compact Rotary Indexing Tables
13Pages

{{requestButtons}}

Catalog excerpts

PGC Compact Rotary Indexing Tables - 1

Compact Rotary indexing Tables GOIZPER YOUR PARTNER IN POWER TRANSMISSION

Open the catalog to page 1
PGC Compact Rotary Indexing Tables - 2

GOIZPER INDUSTRIAL IS ONE OF THE LEADING TECHNOLOGICAL COMPANIES OFFERING GLOBAL SOLUTIONS IN POWER TRANSMISSION Index Rotary Tables, Roller cams and Barrell cam indexers, Brakes, Clutches, Clutch-brakes, Gear Boxes, etc. Goizper designs, manufactures and markets customised power transmission and solutions to meet different market needs in sectors and applications like metal forming, automotive, aeronautics, packaging, automation, construction, marine, machine tools, etc. More than 60 years working alongside customers, studying the market and investigating solutions allow GOIZPER to offer...

Open the catalog to page 2
PGC Compact Rotary Indexing Tables - 3

PGC - HIGH PERFORMANCE FIXED STOP TURN TABLE PGC fixed stop indexing tables are ideal for applications that require the highest accuracy, reliability and high-speed rotation. Extension of service life with electronic ICS2 (pages 10-11). Goizper PGC design provides characteristics as: > Low working height due to compact design > Robust rotary indexing table with smooth running > Extremely long service life, combinable with ICS2 > Large central opening for cable entries > Highest accuracy and repeatability > Zero backlash > Optimized cam motion for smoother stop > Fixed central column >...

Open the catalog to page 3
PGC Compact Rotary Indexing Tables - 4

General information TECHNICAL DATA Stops 2-12: ±30’’ Stops 16-24: ±45’’ ø 30 mm 30 kg Indexing precision Hollow Shaft Weight OUTPUT PLATE (ROTARY) 600 Nm 6500 N 6000 N Nominal Output tilting torque Nominal Axial Force Nominal Radial Force CENTRAL COLUM (STATIONARY) 300 Nm 4000 N 2800 N Nominal Output tilting torque Nominal Axial Force Nominal Radial Force Ø 90 (rotating) Ø 90 (rotating) Ø75 (fixed) Ø75 (fixed) Ø 90 (rotating) Ø30 (fixed) Ø30 (fixed) Ø75 (fixed) Ø 160 Ø 160 (rotating) (rotating) Air Air vent vent Ø 160 (rotating) *Drive motor size 56 (6x) M6x12 on Ø65 on fixed central column...

Open the catalog to page 4
PGC Compact Rotary Indexing Tables - 5

t1 = index time. The total time from the start signal to the inductive sensor indication could add up to 150 ms depending on different factors: electric response time, etc. J = total moment of inertia in kg.m2 * ICS2 control system is recommendeded to avoid motor brake wear. Technical data ICS2 summary Direction of rotation Indexing stops Voltage Drive motor Drive power Clockwise and Counter Clockwise 2, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24, 36 and special angles under requirement 230/400V - 50 Hz and special under request 56 size 0,12 kW ICS2 suitable model ICS2 Drive Power ICS2 Drive Voltage...

Open the catalog to page 5
PGC Compact Rotary Indexing Tables - 6

General information TECHNICAL DATA Stops 2-12: ±25’’ Stops 16-24: ±35’’ ø 50 mm 50 kg Indexing precision Hollow Shaft Weight OUTPUT PLATE (ROTARY) 800 Nm 8500 N 9000 N Nominal Output tilting torque Nominal Axial Force Nominal Radial Force CENTRAL COLUM (STATIONARY) 400 Nm 5500 N 4500 N Nominal Output tilting torque Nominal Axial Force Nominal Radial Force Ø 120 (rotating) Ø 100 (fixed) Ø 220 (rotating) Ø 220 (rotating) *Drive motor size 63 *Drive motor size 63 motor size 63 *Drive motor size 63 (4x) Ø 13 (4x) Ø 13 (6x) M10x14 on Ø200 in this position during dwell (6x) M10x14 on Ø200 (6x)...

Open the catalog to page 6
PGC Compact Rotary Indexing Tables - 7

t1 = index time. The total time from the start signal to the inductive sensor indication could add up to 150 ms depending on different factors: electric response time, etc. J = total moment of inertia in kg.m2 * ICS2 control system is recommendeded to avoid motor brake wear. Technical data ICS2 summary Direction of rotation Indexing stops Voltage Drive motor Drive power ICS2 suitable model ICS2 Drive Power ICS2 Drive Voltage ICS2 Drive Mode

Open the catalog to page 7
PGC Compact Rotary Indexing Tables - 8

General information TECHNICAL DATA Stops 2-12: ±20’’ Stops 16-24: ±30’’ ø 100 mm 180 kg Indexing precision Hollow Shaft Weight OUTPUT PLATE (ROTARY) 2500 Nm 16500 N 15000 N Nominal Output tilting torque Nominal Axial Force Nominal Radial Force CENTRAL COLUM (STATIONARY) 2000 Nm 19000 N 12000 N Nominal Output tilting torque Nominal Axial Force Nominal Radial Force Ø 100 (fixed) Ø 180 (fixed) Ø 100 (fixed) *Dimensions in case of motor size 80 *Dimensions in case of motor size 80 *Dimensions in case *Drive motor size 80 of motor size 80 (6x) M10x15 on(6x) M10x15 on Ø160 Ø160 on fixed central...

Open the catalog to page 8
PGC Compact Rotary Indexing Tables - 9

t1 = index time. The total time from the start signal to the inductive sensor indication could add up to 150 ms depending on different factors: electric response time, etc. J = total moment of inertia in kg.m2 * ICS2 control system is recommendeded to avoid motor brake wear. Technical data ICS2 summary Direction of rotation Indexing stops Voltage Drive motor Drive power ICS2 suitable model ICS2 Drive Power ICS2 Drive Voltage ICS2 Drive Mode Monophase Monophase Triphase

Open the catalog to page 9
PGC Compact Rotary Indexing Tables - 10

ICS2. INDEX CONTROL SYSTEM FOR ROTARY INDEXING TABLE Electronic packaged for the index control system to optimize the cycle time. Stop at the end of dwell, more production in less time. Extended warranty, soft re-start after e-stop. No brake wear. Easy& fast set-up. Web face interface. Error analysis via the historic display. Simplifies logic on Master PLC. Rotary table Technical Characteristics. Powers available Triphase (> 4 kW) Working modes:

Open the catalog to page 10
PGC Compact Rotary Indexing Tables - 11

User friendly. Intuitive web-based interface for startup. Easy & fast set-up. Saving time. Cycle time optimization. By stopping at the end of the station (dwell area). -> More production in less time. Brake with no wear. Only used for E-stop and parking. 2 Working modes. Auto & Jog. -> After emergency stop. JOG MODE protects Indexer's mechanics with soft start. -> STO available. Highest safety level. -> Extended warranty. -> Rapid error analysis. Via historic error display. -> Simplifies logic in Master PLC.

Open the catalog to page 11
PGC Compact Rotary Indexing Tables - 12

CUSTOMER CONTACT DETAILS ROTATING PLATE - DIAL PLATE DIMENSIONS / EXTERNAL FORCES & WEIGHT DIAMETER (D) | ~| mm If toolings are from different sizes, please, indicate the biggest "d1" and "ml". DIAMETER (d1) | ~| mm ADDITIONAL EXTERNAL FORCES SPECIAL NOTES / MORE INFORMATION

Open the catalog to page 12

All GOIZPER catalogs and technical brochures

  1. smart G

    4 Pages

  2. ZPGI