Catalog excerpts
MELT INDEX The evolution of the melt index measurement!
Open the catalog to page 1Melt Index mi2 Series Flexible, compatible, systematic: Step by step from the simple boarding device mi2.1 to the upgraded semi-automated unit mi2.3. The evolution of the melt index measurement! • Brilliant touch screen display for the operation, program control and display of the test results • Temperature control by 2 heater elements, resolution 0.01°C • 5 calibration sets for set temperature with respective parameter files • Storage of up to 500 parameter sets with 3000 measurements for each parameter set in stand alone operation • High-resolution position transducer to measure volume...
Open the catalog to page 2Melt Index MI-3 • The selected test weights are internally installed; manual and therefore dangerous weight handling is eliminated • Users may simply select test weights using a lever that activates the electrical weight handling system • A specially designed guidance system for the test weights ensures that measurements are not influenced by weights being slightly slanted, skew, or off center, which would lead to errors • To ensure convenient access to the test chamber, it can be swiveled by 45°. The use of a special cable system ensures many years of service and is especially designed to...
Open the catalog to page 3Options mi2 series, MI-3, MI-4 • Die swell unit • Manual die plug (also heatable for polymers with high temperature) • Automated die plug • Manual or automated melt cutting unit (also for sticky polymers) • Interfaced melt density determination by integrated balance • Time saving: Pneumatic compress and press through device for high viscous materials (MI-3 and MI-4) • Nitrogen purging for hygroscopic polymers • Barrel and piston in corrosion resistant or abrasion resistant design • Automated backup of all values in the event of power failure via UPS Multi-Load-Test Glancing at the MI-4, one...
Open the catalog to page 4Loading functionality Compressing Many polymers are very sensitive when it comes to packing and pre-loading, where handling differences directly impact measurement accuracy and repeatability. The test devices offer different ways to pack and how to apply a pre-load to the test material. This control covers the complete pre-heat/melt time. Either the time spent on each is controlled, or the position of the piston /material at a specific point in the barrel. The loads used are chosen manually with the mi2.3 and MI-3, automatically with the MI-4. Melting time Post measurement First compression...
Open the catalog to page 5The next generation of the Fully Automated Melt Indexer which meets the standards ISO 1133, ASTM D 1238, BS 2782 and NF 51-016 to measure pellets, powders and similar material profiles. Achievable Precision / Reproducibility: Target value reference material: 7.63 Tolerance: +/- 0.2 Tolerance MI-ROBO: +/- 0.1 Standard deviation: < 0.04 (number of tests: 50) MI-ROBO in Standard design, here with option nitrogen purging All standard or individual weight combinations possible Well proven technology, less maintenance efforts Compact design for a minimum on room space Precise manufacturing for...
Open the catalog to page 6Fully automated Measurement > Automated measuring mode > Automated material feeding > Automated cleaning > Automated die change The Technical Highlights • Integrated sample magazine for 30 single tests, to fill with plastic granules, powder and similar material profiles • Control by Panel-PC with real-time oprating system and 5,7“ Touch Screen Display • MFRHost PC-Software for parameterization, online-monitoring and evaluation of MFR/MVR values • Temperature control algorithm, resolution 0 up to 320°C: 0.01 °C, 320 up to 500°C: 0.1°C • Precise digital position sensor to measure volume...
Open the catalog to page 7Load 1 Load 2 Load 3 Load 4 Load 1 Load 2 Load 3 Load 4 Relaxation area Conventional multiple load tests do not provide any relaxation phase while load changing: this results in higher dispersed test values compared to single test load measurements (figure at left). With our new multiple load function (up to 8 weights), being integrated in the MI-4, the material is given enough relaxation time between load changes to minimize any pre-shearing influences. The result is that both, single load tests and multiple load tests are now in high conformity (figure at right). Vergleich 190°C Fühler...
Open the catalog to page 8Model characteristics Test procedure Automated measurement with single Automated measurement with single load and • Automated measurement manual weight selection load and software controlled weight selection • Multi load measurement Test chamber • Two heater circuits, electrically heated, temperature sensor PT100 1/3 DIN • Temperature difference over time: < ± 0.1 °C • Temperature difference over distance (0-70 mm before the die) < ± 0.2 °C of set temperature (temperature range 60 °C to 400 °C) < ± 0.3 °C of set temperature (option: temperature range 400 °C to 500 °C) Load steps in kg...
Open the catalog to page 9Software MFRHost – Measuring and Visualization Programm with Management System The program package is used for parameterization and control of the complete measuring procedure, the graphical display as well as the evaluation. 4 program modules are integrated: - MFRCom for the data transfer and measured value acquisition between PC and the melt index test device MFRPara for creating the test parameter MFRHost for the numerical and graphical display of the measured values with statistical evaluation MFRDS for the numerical and graphical display of the measured die swell values with...
Open the catalog to page 10Software Application Simple handling, quick to learn • Easy to use operating desktop with clear well arranged symbols and menus • The MDI capability enables several test-value databases to be displayed simultaneously • Register Log file with free to define content The module points in overview: Module MFRCom • Data transfer via COM interfaces or Ethernet (1-4 test devices) • Transfer of the parameter from the PC to the test device • Receiving of the measuring data from the test device for the further organization into the respective data bases • After the data transfer automatically a...
Open the catalog to page 11All Göttfert Werkstoff-Prüfmaschinen catalogs and technical brochures
-
RubberView network
1 Pages
-
At-Line Station
12 Pages
-
MINI BYPASS RHEOGRAPH MBR
12 Pages
-
Elastomer-Testing
12 Pages
-
TRICO-Ram
2 Pages
-
Elastomer Testing
12 Pages
-
Software -WinRheo2
1 Pages
-
Extrusiometer - X-TRUDE series
12 Pages
-
Melt Indexer MI - series
12 Pages
-
RHEOGRAPH 20 / 25 / 75 / 120
8 Pages
-
RemoteNet
1 Pages
-
Extrusiometer
12 Pages
-
Rheotens and Haul-Off
4 Pages
-
MI-Cleaning Boy
1 Pages
-
Online Rheometer
12 Pages
-
Rheograph 25E
1 Pages
-
TRICO RAM
2 Pages
-
Capillary Rheometers
8 Pages
-
GÖTTFERT
8 Pages
-
ELASTOGRAPH
12 Pages
Archived catalogs
-
MI-Series
12 Pages
-
rheometer
4 Pages
-
fully automatic rheometer
3 Pages