With Standardized Output Signal and Integrated Temperature Measurement DTA Series Pressure Transducer The DTA defines the industry standard of a pressure measurement in combination with a temperature measurement. One process connection is enough to measure both values. The unit excels in its high quality workmanship and cost efficiency. Its consistent reproducibility and stable measuring values contribute to our measurement accuracies. • Liquid filled measuring system • Maximum reliability through new membrane technology • Standard G-coating to counteract adhesive materials Technical specifications • Combined pressure and temperature measurement • Robust design with G-Armor flexible components Pressure range Accuracy incl. linearity, hysterisis, • Applications with process temperatures of up to 500°C (932 °F) possible Reproducibility in % to full scale • Pressure ranges from 0...50 and 0...2.000 bar (0-725 to 29,000 psi) available Membrane coating • Stable output signals • Longlife design Max. pressure overload without influence on operating value 1,5 x pressure range over 1000 and reproducibility in % to full scale Supply voltage Output signal Transmission medium Process connection Calibration point Insulation resistance Max. temperature at terminal head during Zero point deviation against diaphragm temperature changes at the diaphragm Product variations (examples) % / ° C ( % / 1,8 ° F ) Zero point deviation against temperature chan- Special shaft length ges at terminal head in % / ° C ( % / 1,8 ° F ) Ingress protection housing Ingress protection connector * With standard diaphragm, transmission medium NTXTM and 1/2”20 U