Technical Data: General Description: The D1022S or D1022D is a loop-powered single or dual channel isolated current repeater. It can be used to interface transmitter, to drive I/P converter, fire and smoke detectors or similar switched resistor systems, located in Hazardous Area, requiring a wide output current range (from 1 to 40 mA) to operate properly. When drive I/P converter, positioner, display a current source is connected to the input terminals, while interfacing transmitter or fire and smoke detector a voltage source with current readback can be connected. The transmitter current is sinked from the input terminals operating as a transparent interface. For fire and smoke detector, the triggering of a detector causes a corresponding change in the Safe Area circuit current. A field open circuit reflects a high impedance to the control device circuit. The unit has reverse input polarity protection and ≤ 1 % accuracy. Function: 1 or 2 channels I.S. analog current repeater for transmitters, I/P converter or fire-smoke detectors providing input-output isolation. EMC: Fully compliant with CE marking applicable requirements. Front Panel and Features: 1 Output to Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2. Wide operating current range from 1 to 40 mA. Field open circuit detection. Input/Output isolation. EMC Compatibility to EN61000-6-2, EN61000-6-4. ATEX, IECEx, FM & FM-C, INMETRO, EAC-EX, UKR TR n. 898 Certifications. Type Approval Certificate DNV and KR for marine applications. High Reliability, SMD components. High Density, two channels per unit. Loop Powered Current Repeater DIN-Rail Models D1022S, D1022D Supply: No supply voltage required because loop-powered. Power dissipation: ≤ 1.1 W per channel at 40 mA, 30 V loop supply. Isolation (Test Voltage): I.S. Out/In 1.5 KV; I.S. Out/I.S. Out 500 V; In/In 500 V. Output Signal to Hazardous Area: Output: 1 to 40 mA. Output characteristic (typical): Vout = (Vin - 1.5) - (0.4 x Iout) for 6 V < Vin < 23 V. Vout = 22 - (0.4 x Iout) for 23 V < Vin < 30 V. 4-20 mA output on load of 100 to 600 Ω; Accuracy ≤ 1 %. Response time: 50 ms (10 to 90 % step change). Input Signal to Safe Area: Operating voltage range: 6 to 30 V (loop powered). Input current: 1 to 40 mA (loop powered). Voltage drop-out: 9.5 V at 20 mA and with 500 Ω load. Open circuit consumption: ≤ 0.4 mA at 20 V. Performance: Reference ambient temperature conditions: 23 ± 1 °C. Current transfer error: ≤ 400 µA (6 V
Open the catalog to page 1Parameters Table: Safety Description Image: Maximum External Parameters Group Cenelec Terminals 13-14, 15-16 Uo/Voc = 25.2 V IIC 0.107 Io/Isc = 93 mA IIB 0.820 Po/Po = 581 mW IIA 2.900 NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Function Diagram: HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, CLASS I, ZONE 0, GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS...
Open the catalog to page 2All GM International srl catalogs and technical brochures
-
5700
4 Pages
-
D1010
4 Pages
-
D1010 -046
4 Pages
-
D1012
2 Pages
-
D1052
4 Pages
-
D1061 -077
2 Pages
-
D1072
6 Pages
-
D5020
2 Pages
-
D1020
2 Pages
-
D5030
2 Pages
Archived catalogs
-
Models D5030S, D5030D
4 Pages
-
Company Profile English
20 Pages
-
Product overview
56 Pages