D1010 - 1

Technical Data: General Description: The single and dual channel DIN Rail Repeater Power Supply, D1010S and D1010D, provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA transmitters, or separately powered 3, 4 wires 4-20, 0-20 mA transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The circuit allows bi-directional communication signals, for Hart-Smart transmitters. Function: 1 or 2 channels I.S. analog input for 2 wires loop powered or separately powered Smart transmitters, provides 3 port isolation (input/output/supply) and current (source or sink) or voltage output signal. Signalling LED: Power supply indication (green). Field Configurability: mA (source or sink) or V output signal. Smart Communication Frequency Band: 0.5 to 40 KHz within 3 dB (Hart and higher frequency protocols). EMC: Fully compliant with CE marking applicable requirements. Functional Safety Management Certification: G.M. International is certified by TUV to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. Front Panel and Features: 1 Tproof = 7 / 10 years (≤10% / >10 % of total SIF) with active input. SIL 2 according to IEC 61508:2010 Ed. 2 for Tproof = 6 / 10 years (≤10% / >10 % of total SIF) with passive input. PFDavg (1 year) 1.30 E-04, SFF 80.51 % with active input. PFDavg (1 year) 1.47 E-04, SFF 80.81 % with passive input. SIL 3 Systematic capability. Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2. 4-20 or 0-20 mA Input, Output Signal. Wide Band Smart Communication, Hart compatible. Input and Output short circuit proof. High Accuracy. Three port isolation, Input/Output/Supply. EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1 In-field programmability by DIP Switch. ATEX, IECEx, UL & C-UL, FM & FM-C, INMETRO, EAC-EX, UKR TR n. 898, TÜV Certifications. TÜV Functional Safety Certification. Type Approval Certificate DNV and KR for maritime applications. High Reliability, SMD components. High Density, two channels per unit. Simplified installation using standard DIN Rail and plug-in terminal blocks. 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. Ordering Information: Model: 1 channel 2 channels Power Bus enclosure SIL 2 Repeater Power Supply Smart-Hart compatible DIN-Rail Models D1010S, D1010D Supply: 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp. Current consumption @ 24 V: 115 mA for 2 channels D1010D, 60 mA for 1 channel D1010S with 20 mA output typical. Power dissipation: 1.9 W for 2 channels D1010D, 1.0 W for 1 channel D1010S with 24 V supply voltage and 20 mA output typical. Max. power consumption: at 30 V supply voltage and short circuit condition, 3.7 W for 2 channels D1010D, 2.0 W for 1 channel D1010S. Isolation (Test Voltage): I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V. Input: 0/4 to 20 mA (separately powered input, voltage drop ≤ 0.9 V) or 4 to 20 mA (2 wire Tx current limited at ≈ 25 mA). Transmitter line voltage: ≥ 15.0 V at 20 mA with max. 20 mVrms ripple on 0.5 to 40 KHz frequency band. Output: 0/4 to 20 mA, on max. 600 Ω load in source mode; V min. 5 V at 0 Ω load V max. 30 V in sink mode, current limited at ≈ 23 mA or 0/1 to 5 V on internal 250 Ω shunt (or 0/2 to 10 V on internal 500 Ω shunt on request). Response time: 50 ms (10 to 90 % step change). Output ripple: ≤ 20 mVrms on 250 Ω communication load on 0.5 to 40 KHz band. Frequency response: 0.5 to 40 KHz bidirectional within 3 dB (Hart and higher frequency protocols). Performance: Ref. Conditions 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature. Calibration accuracy: ≤ ± 0.1 % of full scale. Linearity error: ≤ ± 0.05 % of full scale. Supply voltage influence: ≤ ± 0.05 % of full scale for a min to max supply change. Load influence: ≤ ± 0.05 % of full scale for a 0 to 100 % load resistance change. Temperature influence: ≤ ± 0.01 % on zero and span for a 1 °C change. Compatibility: CE mark compliant, conforms to Directive: 2014/34/EU ATEX, 2014/30/EU EMC, 2014/35/EU LVD, 2011/65/EU RoHS. Environmental conditions: Operating: temperature limits -20 to + 60 °C, relative humidity max 95 %. Storage: temperature limits -45 to + 80 °C. Safety Description: ATEX: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; II 3G Ex ec IIC T4 Gc IECEx: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I; Ex ec IIC T4 Gc INMETRO: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I UL: NI / I / 2 / ABCD / T4, AIS / I, II, III / 1 / ABCDEFG, AEx nC [ia] IIC C-UL: NI / I / 2 / ABCD / T4, AIS / I, II, III / 1 / ABCDEFG, Ex nC [ia] IIC FM: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, AEx [ia] IIC FM-C: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, Ex [ia] IIC EAC-EX: 2Ex nA [ia Ga] IIC T4 Gc X, [Ex ia Da] IIIC X, [Ex ia Ma] I X UKR TR n. 898: 2ExnAiaIICT4 X, ExiaI X Uo/Voc = 26.3 V, Io/Isc = 91 mA, Po/Po = 597 mW at terminals 14-15, 10-11. Uo/Voc = 1.1 V, Io/Isc = 38 mA, Po/Po = 11 mW at terminals 15-16, 11-12. Ui/Vmax = 30 V, Ii/Imax = 104 mA, Ci = 1.05 nF, Li = 0 nH at terminals 15-16, 11-12. Um = 250 Vrms, -20 °C ≤ Ta ≤ 60 °C. Approvals: DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11. IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11. IMQ 09 ATEX 013 X conforms to EN60079-0, EN60079-7. IECEx IMQ 13.0011X conforms to IEC60079-0, IEC60079-7. INMETRO DNV 13.0108 X conforms to ABNT NBR IEC60079-0, ABNT NBR IEC60079-11. UL & C-UL E222308 conforms to UL913, UL 60079-0, UL60079-11, UL60079-15, ANSI/ISA 12.12.01 for UL and CSA-C22.2 No.157-92, CSA-E60079-0, CSA-E60079-11, CSA-C22.2 No. 213 and CSA-E60079-15 for C-UL. FM & FM-C No. 3024643, 3029921C, conforms to Class 3600, 3610, 3611, 3810, ANSI/ISA 12.12.02, ANSI/ISA 60079-0, ANSI/ISA 60079-11, C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15. ЕАЭС RU С-IT.HA67.B.00113/20 conforms to GOST 31610.0, GOST 31610.11, GOST 31610.15. CЦ 16.0034 X conforms to ДСТУ 7113, ГОСТ 22782.5-78, ДСТУ IЕС 60079-15. TÜV Certificate No. C-IS-236198-03, SIL 2 conforms to IEC61508:2010 Ed.2. SIL 3 Functional Safety TÜV Certificate conforms to IEC61508:2010 Ed.2, for Management of Functional Safety. DNV No. TAA00002BM and KR No.MIL20769-EL001 Cert. for maritime applications. Mounting: EN/IEC60715 TH 35 DIN-Rail. Weight: about 175 g D1010D, 125 g D1010S. Connection: by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm2. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. Protection class: IP 20. Dimensions: Width 22.5 mm, Depth 99 mm, Height 114.5 mm. Power Bus and DIN-Rail accessories: DIN rail anc

Open the catalog to page 1

All GM International srl catalogs and technical brochures

  1. 5700

    4 Pages

  2. D1010 -046

    4 Pages

  3. D1012

    2 Pages

  4. D1022

    2 Pages

  5. D1052

    4 Pages

  6. D1061 -077

    2 Pages

  7. D1072

    6 Pages

  8. D5020

    2 Pages

  9. D1020

    2 Pages

  10. D5030

    2 Pages

Archived catalogs