Catalog excerpts
Technical Data: General Description: The single and dual channel DIN Rail Repeater Power Supply, D1010S and D1010D, provides a fully floating dc supply for energizing conventional 2 wires 4-20 mA transmitters, or separately powered 3, 4 wires 4-20, 0-20 mA transmitters located in Hazardous Area, and repeats the current in floating circuit to drive a Safe Area load. The circuit allows bi-directional communication signals, for Hart-Smart transmitters. Function: 1 or 2 channels I.S. analog input for 2 wires loop powered or separately powered Smart transmitters, provides 3 port isolation (input/output/supply) and current (source or sink) or voltage output signal. Signalling LED: Power supply indication (green). Field Configurability: mA (source or sink) or V output signal. Smart Communication Frequency Band: 0.5 to 40 KHz within 3 dB (Hart and higher frequency protocols). EMC: Fully compliant with CE marking applicable requirements. Functional Safety Management Certification: G.M. International is certified by TUV to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. Front Panel and Features: 1 Tproof = 7 / 10 years (≤10% / >10 % of total SIF) with active input. SIL 2 according to IEC 61508:2010 Ed. 2 for Tproof = 6 / 10 years (≤10% / >10 % of total SIF) with passive input. PFDavg (1 year) 1.30 E-04, SFF 80.51 % with active input. PFDavg (1 year) 1.47 E-04, SFF 80.81 % with passive input. SIL 3 Systematic capability. Input from Zone 0 (Zone 20), Division 1, installation in Zone 2, Division 2. 4-20 or 0-20 mA Input, Output Signal. Wide Band Smart Communication, Hart compatible. Input and Output short circuit proof. High Accuracy. Three port isolation, Input/Output/Supply. EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1 In-field programmability by DIP Switch. ATEX, IECEx, UL & C-UL, FM & FM-C, INMETRO, EAC-EX, UKR TR n. 898, TÜV Certifications. TÜV Functional Safety Certification. Type Approval Certificate DNV and KR for maritime applications. High Reliability, SMD components. High Density, two channels per unit. Simplified installation using standard DIN Rail and plug-in terminal blocks. 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier. Ordering Information: Model: 1 channel 2 channels Power Bus enclosure SIL 2 Repeater Power Supply Smart-Hart compatible DIN-Rail Models D1010S, D1010D Supply: 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp. Current consumption @ 24 V: 115 mA for 2 channels D1010D, 60 mA for 1 channel D1010S with 20 mA output typical. Power dissipation: 1.9 W for 2 channels D1010D, 1.0 W for 1 channel D1010S with 24 V supply voltage and 20 mA output typical. Max. power consumption: at 30 V supply voltage and short circuit condition, 3.7 W for 2 channels D1010D, 2.0 W for 1 channel D1010S. Isolation (Test Voltage): I.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V. Input: 0/4 to 20 mA (separately powered input, voltage drop ≤ 0.9 V) or 4 to 20 mA (2 wire Tx current limited at ≈ 25 mA). Transmitter line voltage: ≥ 15.0 V at 20 mA with max. 20 mVrms ripple on 0.5 to 40 KHz frequency band. Output: 0/4 to 20 mA, on max. 600 Ω load in source mode; V min. 5 V at 0 Ω load V max. 30 V in sink mode, current limited at ≈ 23 mA or 0/1 to 5 V on internal 250 Ω shunt (or 0/2 to 10 V on internal 500 Ω shunt on request). Response time: 50 ms (10 to 90 % step change). Output ripple: ≤ 20 mVrms on 250 Ω communication load on 0.5 to 40 KHz band. Frequency response: 0.5 to 40 KHz bidirectional within 3 dB (Hart and higher frequency protocols). Performance: Ref. Conditions 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature. Calibration accuracy: ≤ ± 0.1 % of full scale. Linearity error: ≤ ± 0.05 % of full scale. Supply voltage influence: ≤ ± 0.05 % of full scale for a min to max supply change. Load influence: ≤ ± 0.05 % of full scale for a 0 to 100 % load resistance change. Temperature influence: ≤ ± 0.01 % on zero and span for a 1 °C change. Compatibility: CE mark compliant, conforms to Directive: 2014/34/EU ATEX, 2014/30/EU EMC, 2014/35/EU LVD, 2011/65/EU RoHS. Environmental conditions: Operating: temperature limits -20 to + 60 °C, relative humidity max 95 %. Storage: temperature limits -45 to + 80 °C. Safety Description: ATEX: II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I; II 3G Ex ec IIC T4 Gc IECEx: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I; Ex ec IIC T4 Gc INMETRO: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I UL: NI / I / 2 / ABCD / T4, AIS / I, II, III / 1 / ABCDEFG, AEx nC [ia] IIC C-UL: NI / I / 2 / ABCD / T4, AIS / I, II, III / 1 / ABCDEFG, Ex nC [ia] IIC FM: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, AEx [ia] IIC FM-C: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, Ex [ia] IIC EAC-EX: 2Ex nA [ia Ga] IIC T4 Gc X, [Ex ia Da] IIIC X, [Ex ia Ma] I X UKR TR n. 898: 2ExnAiaIICT4 X, ExiaI X Uo/Voc = 26.3 V, Io/Isc = 91 mA, Po/Po = 597 mW at terminals 14-15, 10-11. Uo/Voc = 1.1 V, Io/Isc = 38 mA, Po/Po = 11 mW at terminals 15-16, 11-12. Ui/Vmax = 30 V, Ii/Imax = 104 mA, Ci = 1.05 nF, Li = 0 nH at terminals 15-16, 11-12. Um = 250 Vrms, -20 °C ≤ Ta ≤ 60 °C. Approvals: DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11. IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11. IMQ 09 ATEX 013 X conforms to EN60079-0, EN60079-7. IECEx IMQ 13.0011X conforms to IEC60079-0, IEC60079-7. INMETRO DNV 13.0108 X conforms to ABNT NBR IEC60079-0, ABNT NBR IEC60079-11. UL & C-UL E222308 conforms to UL913, UL 60079-0, UL60079-11, UL60079-15, ANSI/ISA 12.12.01 for UL and CSA-C22.2 No.157-92, CSA-E60079-0, CSA-E60079-11, CSA-C22.2 No. 213 and CSA-E60079-15 for C-UL. FM & FM-C No. 3024643, 3029921C, conforms to Class 3600, 3610, 3611, 3810, ANSI/ISA 12.12.02, ANSI/ISA 60079-0, ANSI/ISA 60079-11, C22.2 No.142, C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15. ЕАЭС RU С-IT.HA67.B.00113/20 conforms to GOST 31610.0, GOST 31610.11, GOST 31610.15. CЦ 16.0034 X conforms to ДСТУ 7113, ГОСТ 22782.5-78, ДСТУ IЕС 60079-15. TÜV Certificate No. C-IS-236198-03, SIL 2 conforms to IEC61508:2010 Ed.2. SIL 3 Functional Safety TÜV Certificate conforms to IEC61508:2010 Ed.2, for Management of Functional Safety. DNV No. TAA00002BM and KR No.MIL20769-EL001 Cert. for maritime applications. Mounting: EN/IEC60715 TH 35 DIN-Rail. Weight: about 175 g D1010D, 125 g D1010S. Connection: by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm2. Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation. Protection class: IP 20. Dimensions: Width 22.5 mm, Depth 99 mm, Height 114.5 mm. Power Bus and DIN-Rail accessories: DIN rail anc
Open the catalog to page 1All GM International srl catalogs and technical brochures
-
5700
4 Pages
-
D1010 -046
4 Pages
-
D1012
2 Pages
-
D1022
2 Pages
-
D1052
4 Pages
-
D1061 -077
2 Pages
-
D1072
6 Pages
-
D5020
2 Pages
-
D1020
2 Pages
-
D5030
2 Pages
Archived catalogs
-
Models D5030S, D5030D
4 Pages
-
Company Profile English
20 Pages
-
Product overview
56 Pages