Catalog excerpts
5700 SIL3 HART® Mux Modem for Termination Board The HART® Multiplexer Modem interfaces up to 256 smart devices (transmitters, I/P, proportional valves, etc…) in a HART® Network. Each device can be fully identified, configured and monitored either by a remote PC running an FDT-based software package (PACTware™, etc...) through a dedicated Device Type Manager (DTM), by HART® OPC Server, or by a specific asset management system. Up to 63 Multiplexer Modem (16128 loops) can be connected in multi-drop mode to the PC through the RS485 HART® Protocol, whose baudrate can be configured via software. The module is intended to be mounted on the following Term. Boards: - TB(E)-D5001-HRT-003: to be used with GMI AI/AO Term. Boards; - TB(E)-D5001-HRT-004: to be used with DIN-Rail mounted barriers/isolators or direct field connections, 4-20 mA loop signals, AI card impedance = 250 Ω; - TB(E)-D5001-HRT-005: to be used with DIN-Rail mounted barriers/isolators or direct field connections, 1-5 V loop signals; - TB(E)-D5001-HRT-006: to be used with DIN-Rail mounted barriers/isolators or direct field connections, 4-20 mA loop signals, AI card impedance = 100÷150 Ω; - TB(E)-D5001-HRT-007: to be used with DIN-Rail mounted barriers/isolators or direct field connections, 4-20 mA loop signals, AI card impedance = 0÷50 Ω. Termination board types can be combined to manage different interfaces at the same time, provided the maximum number of channels is not exceeded. The HART® Multiplexer Modem is SIL 3 certified as non-interfering with the signal loops. FEATURES SIL 3 / SC 3 Installation in Zone 2/Div. 2 Up to 256 channels (extendable to 16128 with 63 multi-drop units) HART® RS-485 interface to access field smart devices Three port isolation, Field Interface/Serial Interface/Supply Simplified installation on custom Termination Boards TECHNICAL DATA Supply 24 Vdc nom (18 to 30 Vdc) reverse polarity protected, provided through Termination Board. Current consumption: 20 mA @ 24 Vdc typical (modem only), 40 mA @ 24 Vdc in full topology (with maximum number of extension boards), typical. Power dissipation: 0.5 W @ 24 Vdc typical (modem only), 1 W @ 24 Vdc in full topology (with maximum number of extension boards), typical. Field Interface Number of channels: 256. HART® field device revision: 5 to 7. Write Protection The HART® Multiplexer Modem 5700 can be protected against writing by shorting terminals 7 and 8. Serial Interface Type: RS-485 differential pair and grounding. Topology: multi-drop, master/slave connection. Address: 0 - 62, software configurable. Baudrate: from 1200 to 115200 bps, software configurable. Isolation Field Interface/Serial Interface 500 V; Field Interface/Supply 500 V; Supply/Serial Interface 500 V. Environmental conditions Operating temperature: temperature limits –40 to +70 °C. Max altitude: 2000 m a.s.l. Storage temperature: temperature limits –45 to +80 °C. Mounting on custom Term. Board. Weight: about 100 g. Location: installation in Safe Area or Zone 2, Group IIC T4, or Class 1, Div. 2, Group A, B, C, D, T4. Connection: Width 235 mm, Depth 135 mm, Height 154 mm. Dimensions: Width 12.5 mm, Depth 123 mm, Height 120 mm. ORDERING INFORMATION OVERALL DIMENSIONS Ordering codes 5700: supports PACTware™, HART® OPC Server, ABB Ability™, Endress+Hauser FieldCare™, etc., any software FDT/DTM compliant 5700-110: supports Emerson AMS™ Accessories Programmable USB serial line Kit PPC5092 + SWC5090. Functional Safety Management Certification: GM International is certified to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. In addition, GM International products have been granted I.S. certificates from the most credited Notified Bodies in the world. Data specified in this document are merely descriptive of the products and should be integrated with relevant technical specifications. Our products are in constant development and the information presented herein refers to the time of document issue. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. Terms & Conditions can be found at our website. For more information refer to istruction manual. DTS0640-8
Open the catalog to page 1FUNCTION DIAGRAM Additional installation diagrams may be found in Instruction Manual. Field Functional Safety Management Certification: GM International is certified to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. In addition, GM International products have been granted I.S. certificates from the most credited Notified Bodies in the world. Data specified in this document are merely descriptive of the products and should be integrated with relevant technical specifications. Our products are in constant development and the information...
Open the catalog to page 2HART MUX + GMI TERM. BOARDS NETWORK Functional Safety Management Certification: GM International is certified to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. In addition, GM International products have been granted I.S. certificates from the most credited Notified Bodies in the world. Data specified in this document are merely descriptive of the products and should be integrated with relevant technical specifications. Our products are in constant development and the information presented herein refers to the time of document issue. No...
Open the catalog to page 3HART MUX + BARRIERS/ISOLATORS NETWORK Functional Safety Management Certification: GM International is certified to conform to IEC61508:2010 part 1 clauses 5-6 for safety related systems up to and included SIL3. In addition, GM International products have been granted I.S. certificates from the most credited Notified Bodies in the world. Data specified in this document are merely descriptive of the products and should be integrated with relevant technical specifications. Our products are in constant development and the information presented herein refers to the time of document issue. No...
Open the catalog to page 4All GM International srl catalogs and technical brochures
-
D1010
4 Pages
-
D1010 -046
4 Pages
-
D1012
2 Pages
-
D1022
2 Pages
-
D1052
4 Pages
-
D1061 -077
2 Pages
-
D1072
6 Pages
-
D5020
2 Pages
-
D1020
2 Pages
-
D5030
2 Pages
Archived catalogs
-
Models D5030S, D5030D
4 Pages
-
Company Profile English
20 Pages
-
Product overview
56 Pages