Vane air motor V12 series
1 /24Pages

Vane air motor V12 series

Vane air motor V12 series
1 /24Pages

Catalog excerpts

Vane air motor V12 series-1

GLOBE® AIRMOTORS B.V. GLOBE Airmotors | Boerhaaveweg 9-11 | NL - 2408 AD Alphen a/d Rijn | Tel +31 172 426 608 | [email protected] Manual GLOBE Vane Air Motor VS12C | VA12C ATEX certified

 Open the catalog to page 1
Vane air motor V12 series-2

Equipment group II for use above ground Category 2G for use in Zone 1 or 2 Category 2D for use in Zone 21 or 22 Protection by constructional safety "c" Gas group IIC Dust group IIIC Temperature class T4 Maximum surface temperature 135°C Equipment protection level Gb Equipment protection level Db Ambient temperature range ATEX CERTIFICATION The GLOBE vane air motors are ATEX certified according to the following (harmonized) standards: The motors are marked with the following EX marking: Checklist to comply to ATEX 4 Shutdown and long storage 12 Summary of the hazards with protective means: 12...

 Open the catalog to page 2
Vane air motor V12 series-3

Congratulations with your GLOBE air motor! This product is made with quality materials to meet the highest standards. This manual contains safety instructions for the use of your GLOBE air motor. Please read and follow all recommended instructions for a troublefree use. Warranty The GLOBE air motor is designed to operate without any problems. This is only guaranteed if the regulations with regards to installation, operation, maintenance and repair are observed. Problems occurring during the guarantee period are corrected in accordance to GLOBE Airmotors BV guarantee conditions. All results of...

 Open the catalog to page 3
Vane air motor V12 series-4

Checklist to comply to ATEX: » To check that the air motor is designed for use in hazardous applications read the air motor label: » Hazardous zone » Hazardous category » Equipment group » Temperature class » Maximum surface temperatures » Check the air motor before installation and operation to see if it’s not damaged. » Any products that are driven by the air motor must meet appropriate ATEX approval as well to be used in a hazardous area. » The air motor should be connected to the earth with a maximum earth resistance of 1MΩ. The motor can be earthed by connecting the motor to a base plate/gearbox...

 Open the catalog to page 4
Vane air motor V12 series-5

Correct installation is your responsibility! Make sure you have the proper installation conditions. A Install proper guard around the output shaft if needed. Wear eye protection: Airflow from product may contain solid or liquid materials that can result in eye or skin damage. A Failure to follow these instructions can result in serious injury or property damage. It's important that no dust or debris can accumulate at the output shaft. This may damage the shaft seal. If the motor is built in a closed system or construction so that no dust or debris can get in contact with the output shaft the...

 Open the catalog to page 5
Vane air motor V12 series-6

Installation Use a puller to remove pulleys, pinions and couplings. Check if the tension on the belt pulley matches the specifications of the manufacture. Do not exceed the maximum radial and axial forces on the shaft. If the motor shaft is connected to the part to be driven without a coupling, check that the radial offset and axial force effect will not cause problems. Use only belts with minimal 100 MΩ electrical leakage resistance to prevent static electrical problems. Air supply » Air supply to the motor should always be taken from non-hazardous area. » Remove the plastic shipping plugs from...

 Open the catalog to page 6
Vane air motor V12 series-7

Airline filtration » Use a 64 |jm or finer air filter » The airline filter should be drained regularly and the element examined for signs of clogging. » The airline lubricator should be replenished when needed and set to give the following required drop rate/min: Continuous Operation Intermittent Operation » For normal ambient temperatures 0°C to 32°C. Use oil with viscosity ISO VG 32. » For extremes of ambient temperature consult the manufacturer. Ground the motor to the earth with a maximum earth resistance of 1MQ. GLOBE AIRMOTORS MANUAL | VS12C | VA12C | ATEX certified ■ 7

 Open the catalog to page 7
Vane air motor V12 series-8

Correct operation is your responsibility! Make sure you have the proper operation conditions. Wear eye protection: Air stream from product may contain solid or liquid materials that can result in eye or skin damage. Wear hearing protection: The noise level from the air motor may exceed 85 dB(A) A Do not use combustible gases to drive this air motor Failure to follow these instructions can result in serious injury or property damage. WARNING: POTENTIAL ELECTROSTATIC CHARGING HAZARD Before use clean only with damp cloth. Avoid electrostatic charging mechanisms stronger than manual rubbing. Do not...

 Open the catalog to page 8
Vane air motor V12 series-9

Operation » Check all connections before starting the air motor. It is your responsibility to operate this product at recommended speeds, loads and ambient temperatures (-20°C to +60°C) » Check if the airline filtration and airline lubrication is OK. The airline filter should be drained and/or cleaned regularly and the filter element examined for signs of clogging. » The maximum working pressure is 7 bar (100 PSI). » Clean surface of air motor unit thoroughly of all dustproofing products, contaminants and other impurities. Clean only with damp cloth. » Do not run the air motor at high speeds...

 Open the catalog to page 9
Vane air motor V12 series-10

With the regulation of the inlet pressure and the flow rate, the performance can be adapted to the individual application. This is done by pressure or air flow regulation or a combination of both. The compressibility of the air generates a dampening effect in all ranges. This allows that the motor also can be started, while it is loaded. With a load reduction, the motor reacts immediately with an increase in speed. 1. Pressure regulation With pressure regulation the output power can be adjusted. When the supply pressure is decreased, the torque and power is reduced proportionally and the torque...

 Open the catalog to page 10
Vane air motor V12 series-11

Maintenance Correct maintenance is your responsibility! Make sure you have the proper maintenance conditions. WARNING - Injury hazard Disconnect air supply and vent all air lines. Wear eye protection: Air stream from product may contain solid or liquid materials that can result in eye or skin damage. Flush this product in a well ventilated area. Do not use kerosene or other combustible solvents to flush this product. Failure to follow these instructions can result in serious injury or property damage. » Please ensure that maintenance is carried out by certified staff. You can order your service...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.