GLOBE® AIRMOTORS B.V. GLOBE Airmotors | Boerhaaveweg 9-11 | NL - 2408 AD Alphen a/d Rijn | Tel +31 172 426 608 | [email protected] Manual GLOBE Vane Air Motor VA1X ATEX certified
Open the catalog to page 1Equipment group II for use above ground Category 2G for use in Zone 1 or 2 Category 2D for use in Zone 21 or 22 Protection by constructional safety "c" Gas group IIC Dust group IIIC Temperature class T4 Maximum surface temperature 135°C Equipment protection level Gb Equipment protection level Db Ambient temperature range ATEX CERTIFICATION The GLOBE vane air motors are ATEX certified according to the following (harmonized) standards: The motors are marked with the following EX marking: Checklist to comply to ATEX 4 Shutdown and long storage 12 Summary of the hazards with protective means 13 Dimensions,...
Open the catalog to page 2Congratulations with your GLOBE air motor! This product is made with quality materials to meet the highest standards. This manual contains safety instructions for the use of your GLOBE air motor. Please read and follow all recommended instructions for a troublefree use. Warranty The GLOBE air motor is designed to operate without any problems. This is only guaranteed if the regulations with regards to installation, operation, maintenance and repair are observed. Problems occurring during the guarantee period are corrected in accordance to GLOBE Airmotors BV guarantee conditions. All results of...
Open the catalog to page 3Checklist to comply to ATEX » To check that the air motor is designed for use in hazardous applications read the air motor label: » Hazardous zone » Hazardous category » Equipment group » Temperature class » Maximum surface temperatures » Check the air motor before installation and operation to see if it’s not damaged. » Any products that are driven by the air motor must meet appropriate ATEX approval as well to be used in a hazardous area. » The air motor should be connected to the earth with a maximum earth resistance of 1MΩ. The motor can be earthed by connecting the motor to a base plate/gearbox...
Open the catalog to page 4Correct installation is your responsibility! Make sure you have the proper installation conditions. Install proper guard around the output shaft if needed. Wear eye protection: Airflow from product may contain solid or liquid materials that can result in eye or skin damage. Failure to follow these instructions can result in serious injury or property damage. It's important that no dust or debris can accumulate at the output shaft. This may damage the shaft seal. If the motor is built in a closed system or construction so that no dust or debris can get in contact with the output shaft the air...
Open the catalog to page 5Installation Air supply » Air supply to the motor should always be taken from non-hazardous area. » Remove the plastic shipping plugs from the ports. Save the plugs for the future, during shutdown. » Please make sure that the temperature of the air used for air supply to the air motor don’t exceed the following temperatures, -20°C to +40°C. » Install a filter (64 micron) to make sure the air is clean and dry and install an air pressure regulator to control motor speed and torque. » A lubricator must be placed inside the main airline near the motor. Choose a lubricator suitable for the flow required....
Open the catalog to page 6» Use a 64 |jm or finer air filter » The airline filter should be drained regularly and the element examined for signs of clogging. » The airline lubricator should be replenished when needed and set to give the following required drop rate/min: Continuous Operation Intermittent Operation » For normal ambient temperatures 0°C to 32°C. Use oil with viscosity ISO VG 32. » For extremes of ambient temperature consult the manufacturer. Do not use a hammer on the shaft or body of the motor. Ground the motor to the earth with a maximum earth resistance of 1MQ. Use a puller to remove pulleys, pinions...
Open the catalog to page 7Operation Correct operation is your responsibility! Make sure you have the proper operation conditions. WARNING - Injury hazard Wear eye protection: Air stream from product may contain solid or liquid materials that can result in eye or skin damage. Wear hearing protection: The noise level from the air motor may exceed 85 dB(A) Do not use combustible gases to drive this air motor Failure to follow these instructions can result in serious injury or property damage. Do not run the air motor at high speeds with no load. This will result in excessive internal heat that may cause motor damage. 8 ·...
Open the catalog to page 8» Check all connections before starting the air motor. It is your responsibility to operate this product at recommended speeds, loads and ambient temperatures (-20°C to +60°C) » Check if the airline filtration and airline lubrication is OK. The airline filter should be drained and/or cleaned regularly and the filter element examined for signs of clogging. » The maximum working pressure is 7 bar (100 PSI). » Clean surface of air motor unit thoroughly of all dustproofing products, contaminants and other impurities. Clean only with damp cloth. » Do not run the air motor at high speeds with no load....
Open the catalog to page 9With the regulation of the inlet pressure and the flow rate, the performance can be adapted to the individual application. This is done by pressure or air flow regulation or a combination of both. The compressibility of the air generates a dampening effect in all ranges. This allows that the motor also can be started, while it is loaded. With a load reduction, the motor reacts immediately with an increase in speed. 1. Pressure regulation With pressure regulation the output power can be adjusted. When the supply pressure is decreased, the torque and power is reduced proportionally and the torque...
Open the catalog to page 10Maintenance Correct maintenance is your responsibility! Make sure you have the proper maintenance conditions. WARNING - Injury hazard Disconnect air supply and vent all air lines. Wear eye protection: Air stream from product may contain solid or liquid materials that can result in eye or skin damage. Flush this product in a well ventilated area. Do not use kerosene or other combustible solvents to flush this product. Failure to follow these instructions can result in serious injury or property damage. GLOBE AIRMOTORS MANUAL | VA1X | ATEX certified · 11
Open the catalog to page 1115 Pages
24 Pages
28 Pages
28 Pages
28 Pages
28 Pages
28 Pages
4 Pages
5 Pages
4 Pages
4 Pages
7 Pages
7 Pages
7 Pages
7 Pages
8 Pages
5 Pages
5 Pages
2 Pages
4 Pages
21 Pages
28 Pages
64 Pages
9 Pages
5 Pages
30 Pages
9 Pages
16 Pages
48 Pages
23 Pages
32 Pages
56 Pages
13 Pages
4 Pages
7 Pages
7 Pages
103 Pages
30 Pages
4 Pages
2 Pages
5 Pages
26 Pages
2 Pages
1 Page
20 Pages