Introduction
The document discusses the GLOBE Vane Air Motor VA1X, an ATEX certified device designed for hazardous environments, manufactured by GLOBE Airmotors. It complies with safety and operational standards.

ATEX Certification
The motor is certified for use in explosive atmospheres, suitable for gas group IIC and dust group IIIC, with a temperature class of T4 and a maximum surface temperature of 135°C. It operates within an ambient temperature range of -20°C to +60°C.

Warranty and Safety
The warranty is valid only if guidelines for installation, operation, and maintenance are followed. Unauthorized modifications void the warranty. Safety instructions highlight the need for protective gear and proper grounding to prevent electrostatic hazards.

Installation Guidelines
Proper installation is crucial for performance. The motor should be mounted carefully to avoid misalignment and excessive force on the shaft. An air filter and lubricator must be installed, and the air supply should come from a non-hazardous area.

Operation Instructions
Operators must use the motor under recommended conditions, avoiding high speeds without load to prevent overheating. Regular checks on filters and connections are necessary. The motor should not be exposed to high vibrations without consulting the manufacturer.

Performance Regulation
Performance is adjusted through air flow regulation, maintaining torque while controlling speed. Supply air throttling is preferred for durability and efficiency.

Maintenance and Troubleshooting
Regular maintenance is required, including checking and cleaning filters, ensuring proper lubrication, and monitoring for unusual sounds or vibrations.

Conclusion
The GLOBE VA1X air motor is reliable for hazardous environments if installed and maintained according to guidelines.

Certifications Overview
The document also covers ATEX and UKCA certifications for GLOBE Airmotors' pneumatic vane motors, ensuring compliance with European and UK standards for use in explosive atmospheres.

UKCA Certification
The UKCA Declaration confirms compliance with regulations for use in potentially explosive atmospheres and adherence to harmonized standards.

CE Certification
The CE Declaration confirms compliance with the Machinery Directive, listing various models and adherence to relevant standards.

Technical Documentation
The technical file includes comprehensive data on design and safety features, accessible through the manufacturer's contact details.

Contact Information
GLOBE Airmotors can be contacted via phone or email for further information, with additional resources available on their website.
See more

Catalog excerpts

Vane air motor V1 series-1

GLOBE® AIRMOTORS B.V. GLOBE Airmotors | Boerhaaveweg 9-11 | NL - 2408 AD Alphen a/d Rijn | Tel +31 172 426 608 | [email protected] Manual GLOBE Vane Air Motor VA1X ATEX certified

 Open the catalog to page 1
Vane air motor V1 series-2

Equipment group II for use above ground Category 2G for use in Zone 1 or 2 Category 2D for use in Zone 21 or 22 Protection by constructional safety "c" Gas group IIC Dust group IIIC Temperature class T4 Maximum surface temperature 135°C Equipment protection level Gb Equipment protection level Db Ambient temperature range ATEX CERTIFICATION The GLOBE vane air motors are ATEX certified according to the following (harmonized) standards: The motors are marked with the following EX marking: Checklist to comply to ATEX 4 Shutdown and long storage 12 Summary of the hazards with protective means 13 Dimensions,...

 Open the catalog to page 2
Vane air motor V1 series-3

Congratulations with your GLOBE air motor! This product is made with quality materials to meet the highest standards. This manual contains safety instructions for the use of your GLOBE air motor. Please read and follow all recommended instructions for a troublefree use. Warranty The GLOBE air motor is designed to operate without any problems. This is only guaranteed if the regulations with regards to installation, operation, maintenance and repair are observed. Problems occurring during the guarantee period are corrected in accordance to GLOBE Airmotors BV guarantee conditions. All results of...

 Open the catalog to page 3
Vane air motor V1 series-4

Checklist to comply to ATEX » To check that the air motor is designed for use in hazardous applications read the air motor label: » Hazardous zone » Hazardous category » Equipment group » Temperature class » Maximum surface temperatures » Check the air motor before installation and operation to see if it’s not damaged. » Any products that are driven by the air motor must meet appropriate ATEX approval as well to be used in a hazardous area. » The air motor should be connected to the earth with a maximum earth resistance of 1MΩ. The motor can be earthed by connecting the motor to a base plate/gearbox...

 Open the catalog to page 4
Vane air motor V1 series-5

Correct installation is your responsibility! Make sure you have the proper installation conditions. Install proper guard around the output shaft if needed. Wear eye protection: Airflow from product may contain solid or liquid materials that can result in eye or skin damage. Failure to follow these instructions can result in serious injury or property damage. It's important that no dust or debris can accumulate at the output shaft. This may damage the shaft seal. If the motor is built in a closed system or construction so that no dust or debris can get in contact with the output shaft the air...

 Open the catalog to page 5
Vane air motor V1 series-6

Installation Air supply » Air supply to the motor should always be taken from non-hazardous area. » Remove the plastic shipping plugs from the ports. Save the plugs for the future, during shutdown. » Please make sure that the temperature of the air used for air supply to the air motor don’t exceed the following temperatures, -20°C to +40°C. » Install a filter (64 micron) to make sure the air is clean and dry and install an air pressure regulator to control motor speed and torque. » A lubricator must be placed inside the main airline near the motor. Choose a lubricator suitable for the flow required....

 Open the catalog to page 6
Vane air motor V1 series-7

» Use a 64 |jm or finer air filter » The airline filter should be drained regularly and the element examined for signs of clogging. » The airline lubricator should be replenished when needed and set to give the following required drop rate/min: Continuous Operation Intermittent Operation » For normal ambient temperatures 0°C to 32°C. Use oil with viscosity ISO VG 32. » For extremes of ambient temperature consult the manufacturer. Do not use a hammer on the shaft or body of the motor. Ground the motor to the earth with a maximum earth resistance of 1MQ. Use a puller to remove pulleys, pinions...

 Open the catalog to page 7
Vane air motor V1 series-8

Operation Correct operation is your responsibility! Make sure you have the proper operation conditions. WARNING - Injury hazard Wear eye protection: Air stream from product may contain solid or liquid materials that can result in eye or skin damage. Wear hearing protection: The noise level from the air motor may exceed 85 dB(A) Do not use combustible gases to drive this air motor Failure to follow these instructions can result in serious injury or property damage. Do not run the air motor at high speeds with no load. This will result in excessive internal heat that may cause motor damage. 8 ·...

 Open the catalog to page 8
Vane air motor V1 series-9

» Check all connections before starting the air motor. It is your responsibility to operate this product at recommended speeds, loads and ambient temperatures (-20°C to +60°C) » Check if the airline filtration and airline lubrication is OK. The airline filter should be drained and/or cleaned regularly and the filter element examined for signs of clogging. » The maximum working pressure is 7 bar (100 PSI). » Clean surface of air motor unit thoroughly of all dustproofing products, contaminants and other impurities. Clean only with damp cloth. » Do not run the air motor at high speeds with no load....

 Open the catalog to page 9
Vane air motor V1 series-10

With the regulation of the inlet pressure and the flow rate, the performance can be adapted to the individual application. This is done by pressure or air flow regulation or a combination of both. The compressibility of the air generates a dampening effect in all ranges. This allows that the motor also can be started, while it is loaded. With a load reduction, the motor reacts immediately with an increase in speed. 1. Pressure regulation With pressure regulation the output power can be adjusted. When the supply pressure is decreased, the torque and power is reduced proportionally and the torque...

 Open the catalog to page 10
Vane air motor V1 series-11

Maintenance Correct maintenance is your responsibility! Make sure you have the proper maintenance conditions. WARNING - Injury hazard Disconnect air supply and vent all air lines. Wear eye protection: Air stream from product may contain solid or liquid materials that can result in eye or skin damage. Flush this product in a well ventilated area. Do not use kerosene or other combustible solvents to flush this product. Failure to follow these instructions can result in serious injury or property damage. GLOBE AIRMOTORS MANUAL | VA1X | ATEX certified · 11

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.