THESI 320
2Pages

{{requestButtons}}

Catalog excerpts

THESI 320 - 1

Via Assunta, 57 - 20834 Nova Milanese (MB) - ITALY Tel. +39 0362 366126 Fax +39 0362 366876 www.givimisure.it sales@givimisure.it TECHNICAL DATASHEET THESI 320 POSITION CONTROLLER GENERAL FEATURES • THESI 320 position controller can control shifting and positioning of two axes in 3 different operating modes: - MANUAL, by keyboard; - SEMI-AUTOMATIC, by keyboard; - AUTOMATIC, on the basis of a memorized program. • End of program output. • Independent axes as for configurations and parameters. • 3 generic auxiliary inputs. • Possibility of storing up to 99 PROGRAMS with 20 positions each. Up to 99 repetitions can be matched to each position (the program cycle is composed by the position and its respective repetitions). • 90 Vac to 230 Vac power supply, or 24 Vac power supply with selector. • Manufactured with 16 bit microcontroller, 256K FLASH and 8K RAM memory, in single-chip mode. • 5 Vdc or 12 Vdc encoder input. • Optoisolated inputs. START, STOP, INCREASE CYCLE, DEVIATION, PRESET. • Voltage-free contact outputs. OK POSITION, ENABLING WITH CONTROL INTERLOCK FEED / BACK, SLOW / FAST. • ± 10 Vdc analog output. FEED / BACK, SLOW / FAST, with linear ramp. • Possibility of installation on bench or built in. MECHANICAL AND ELECTRICAL CHARACTERISTICS THESI 320 POSITION = 6 high-efficiency digits h = 13 mm and negative sign CYCLES / PROGRAMS = 2+2 high-efficiency digits h = 13 mm 2 square waves with phase displacement of 90° ± 10° electrical and zero reference 5 Vdc ± 5% or 12 Vdc ± 5% 120 mAMAX 20 kHzMAX 200 - 100 - 50 - 20 - 10 - 5 - 2 - 1 µm permanent for configurations and programs 90 Vac to 230 Vac ± 10% - 50/60 Hz 24 Vac ± 10% - 50/60 Hz 10 WMAX 50 mAMAX (230 Vac) - 400 mAMAX (24 Vac) N.O. relay contacts: 240 VacMAX - 1 AMAX - 120 VAMAX 60 VdcMAX - 2 AMAX - 60 WMAX * ±10 Vdc optoisolated optoisolated by removable terminal block front panel: 193x100 mm - depth: 135.5 mm keyboard IP 65 rear panel IP 40 0 °C ÷ 50 °C -20 °C ÷ 70 °C 1250 g Model Display Signals input Encoder power supply Axes input frequency Linear resolution Memory Power supply Power Current consumption Digital outputs Analog output Inputs Connections Dimensions (DIN 43700) Protection class (EN 60529) Operating temperature Storage temperature Weight * When using the maximum current, the maximum voltage of the relay contacts is precluded. ORDERING CODE MODEL ENCODER POWER SUPPLY = relay (digital) = analog POSITION CONTROLLER THESI 320 DI 05V Pag. 1/2 GIVI MISURE S.R.L. A SOCIO UNICO C.F. e Iscrizione al Reg. Imprese di Monza e Brianza n° 04355540156 - Cap. Soc. € 51.480,00 I.V.

Open the catalog to page 1
THESI 320 - 2

Via Assunta, 57 - 20834 Nova Milanese (MB) - ITALY Tel. +39 0362 366126 Fax +39 0362 366876 www.givimisure.it sales@givimisure.it TECHNICAL DATASHEET CONNECTIONS LEGEND POWER INPUT FUSE GROUND TERMINAL SWITCH COM FB SLOW/AV FAST FEED BACK AUX N.O. RELAY CONTACTS 240 VacMAX - 1 AMAX - 120 VAMAX 60 VdcMAX - 2 AMAX - 60 WMAX V+ VA B Z AUX 1 AUX 2 AUX 3 COM+ PRESET START STOP DEV INC.CYCLE EN. MOV. M-S/A OK POS. END PROG COM FS / A0 = AC voltage power supply (220 Vac, 110 Vac, 24 Vac) = External fuses = Protection ground = AC voltage power supply selector 110/220 Vac or 24 Vac = Encoder power...

Open the catalog to page 2

All GIVI MISURE catalogs and technical brochures

  1. GVS 204

    6 Pages

  2. GVS 200

    6 Pages

  3. VI900

    2 Pages

  4. VISION 900

    5 Pages

  5. VISION 518

    2 Pages

  6. AEN58

    2 Pages

  7. MTT-MTB

    2 Pages

  8. AGM

    2 Pages

  9. AGS

    2 Pages

  10. GVS

    6 Pages

  11. VI518

    2 Pages

  12. THESI 310

    2 Pages

Archived catalogs