THESI 310 - 1

Via Assunta, 57 - 20834 Nova Milanese (MB) - ITALY Tel. +39 0362 366126 Fax +39 0362 366876 www.givimisure.it sales@givimisure.it TECHNICAL DATASHEET THESI 310 POSITION CONTROLLER GENERAL FEATURES • THESI 310 position controller can control axis shifting and positioning in 3 different operating modes: - MANUAL, by keyboard; - SEMI-AUTOMATIC, by keyboard; - AUTOMATIC, on the basis of a memorized program. • Possibility of storing up to 99 PROGRAMS with 20 positions each. Up to 99 repetitions can be matched to each position (the program cycle is composed by the position and its respective repetitions). • 90 Vac to 230 Vac power supply, or 24 Vac power supply with selector. • Manufactured with 16 bit microcontroller, 256K FLASH and 8K RAM memory, in single-chip mode. • 5 Vdc or 12 Vdc encoder input. • Optoisolated inputs. START, STOP, INCREASE CYCLE, DEVIATION, PRESET. • Voltage-free contact outputs. OK POSITION, ENABLING WITH CONTROL INTERLOCK FEED / BACK, SLOW / FAST. • ± 10 Vdc analog output. FEED / BACK, SLOW / FAST, with linear ramp. • Possibility of installation on bench or built in. MECHANICAL AND ELECTRICAL CHARACTERISTICS Model POSITION = 6 high-efficiency digits h = 13 mm and negative sign CYCLES / PROGRAMS = 2+2 high-efficiency digits h = 9 mm Signal input 2 square waves with phase displacement of 90° ± 10° electrical and zero reference Encoder power supply Axis input frequency Linear resolution permanent for configurations and programs Power supply Current consumption Digital outputs N.O. relay contacts: 240 VacMAX - 1 AMAX - 120 VAMAX Analog output by removable terminal block front panel: 144x72 mm - depth: 126 mm Operating temperature Storage temperature 60 VdcMAX - 2 AMAX - 60 WMAX * * When using the maximum current, the maximum voltage of the relay contacts is precluded. ORDERING CODE MODEL ENCODER POWER SUPPLY = relay (digital) = analog POSITION CONTROLLER THESI 310 DI 05V Pag. 1/2 GIVI MISURE S.R.L. A SOCIO UNICO C.F. e Iscrizione al Reg. Imprese di Monza e Brianza n° 04355540156 - Cap. Soc. € 51.480,00 I.V.

Open the catalog to page 1
THESI 310 - 2

Via Assunta, 57 - 20834 Nova Milanese (MB) - ITALY Tel. +39 0362 366126 Fax +39 0362 366876 www.givimisure.it sales@givimisure.it TECHNICAL DATASHEET CONNECTIONS LEGEND POWER INPUT FUSE GROUND TERMINAL SWITCH COM FB / 0V SLOW FAST FEED BACK N.O. RELAY CONTACTS 240 VacMAX - 1 AMAX - 120 VAMAX 60 VdcMAX - 2 AMAX - 60 WMAX V+ VA B Z COM+ COMPRESET START STOP DEV INC.C EN. MOV. OK POS. COM FS / AV = AC voltage power supply (220 Vac, 110 Vac, 24 Vac) = External fuses = Protection ground = AC voltage power supply selector 110/220 Vac or 24 Vac = Encoder power supply output (5 V or 12 V) = Encoder...

Open the catalog to page 2

All GIVI MISURE catalogs and technical brochures

  1. GVS 204

    6 Pages

  2. GVS 200

    6 Pages

  3. VI900

    2 Pages

  4. VISION 900

    5 Pages

  5. VISION 518

    2 Pages

  6. AEN58

    2 Pages

  7. MTT-MTB

    2 Pages

  8. AGM

    2 Pages

  9. AGS

    2 Pages

  10. GVS

    6 Pages

  11. VI518

    2 Pages

  12. THESI 320

    2 Pages

Archived catalogs