Via Assunta, 57 - 20834 Nova Milanese (MB) - ITALY Tel. +39 0362 366126 Fax +39 0362 366876 www.givimisure.it [email protected] TECHNICAL DATASHEET REMOTE BOARD RB900 GENERAL FEATURES • The remote board RB900 provides the VISION 900 digital readout with digital Input/Output (I/O RB900) or with an analog output 0 - 10 V (CSS RB900). • 8 switching outputs with static relays N.O. protected against overload and overcurrent. • 4 optoisolated and independent inputs, for the “Preset” of positions on the axes. • Analog output DAC at 0 - 10 V for “Constant Surface Speed” machinings. • Possibility of storing up to 10 PROGRAMS of relay intervention. For each program, it is possible to set up to 8 operating positions of the relay outputs. • 1 switching output with static relay N.O., for the “Ready” state. • Direct power supply from the digital readout, or external power supply (PWS) 12 - 24 Vac - 50/60 Hz, or 12 - 24 Vdc. • Installation on guide DIN (EN 60715) TH 35. MECHANICAL AND ELECTRICAL CHARACTERISTICS Model Power supply from VISION 900 External power supply (PWS) * Current consumption VinHIGH = 4.5 ÷ 30 Vdc VinLOW = 0 ÷ 2 Vdc optoisolated and independent Digital outputs static N.O. relay contacts, 60 Vac/dcMAX, protected against overload and overcurrent Analog output D-SUB terminal block terminal block Operating temperature Storage temperature (5 Vdc from VI900) (24 Vdc from external power supply PWS) tMIN = 100 ms 0.6 AMAX, 15p M (COM1) 3p M (external power supply PWS) 12p M (input/output) ORDERING CODE MODEL CABLE LENGTH I/O = input/output (digital) CSS = analog output 0 - 10 V standard external power supply isolated +5V output external power supply with isolated +5V output MODULE RB900 I/O PWS M03 Pag. 1/2 GIVI MISURE S.R.L. A SOCIO UNICO C.F. e Iscrizione al Reg. Imprese di Monza e Brianza n° 04355540156 - Cap. Soc. € 51.480,00 I.V.
Open the catalog to page 1Via Assunta, 57 - 20834 Nova Milanese (MB) - ITALY Tel. +39 0362 366126 Fax +39 0362 366876 www.givimisure.it [email protected] TECHNICAL DATASHEET Leave enough space around the module for cables connection. WARNING • The instrument must be installed by specialized personnel in observance of the instructions provided by the Manufacturer. • We recommend the use of a mains power supply provided with an input filter and fuses; the power distribution network to which the instrument is connected must be equipped with a sectioning device in compliance with the regulations in force, positioned closed...
Open the catalog to page 24 Pages
4 Pages
6 Pages
2 Pages
84 Pages
5 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
2 Pages
2 Pages
2 Pages