pyros
1 /4Pages

pyros

pyros
1 /4Pages

Catalog excerpts

pyros-1

STANDARD EQUIPMENT: STANDARD EQUIPMENT: STANDARD EQUIPMENT: • Electric power cable. • Tweezers for insert removing. • Kit of fuses. • Thermostat connection cables. • Instructions manual. • Test report. • Electric power cable. • Tweezers for insert removing. • Kit of fuses. • Thermostat connection cables. • Instructions manual. • Test report. • Insert 2D3332. • Electric power cable. • Tweezers for insert removing. • Kit of fuses. • Thermostat connection cables. • Instructions manual. • Test report. • Insert 2D3133. PYROS140-1H: calibrator 1 hole • 2D3391: 4 holes insert • 2D3463: blank insert PORTABLE TEMPERATURE CALIBRATOR PYROS 140 - PYROS 375 - PYROS 650 Operating range: -24 °C ÷ +650 °C (-11 °F ÷ 1202 °F) PYROS140-2H: calibrator 2 holes • 2D3199-003: 1 hole insert • 2D3199-004: 1 hole insert ORDERING CODES: • 2D3199-000: blank insert (Pyros140-2H only) • 2D3391: 4 holes insert • 2D3463: blank insert • 2D3199-001: 1 hole insert • 2D3199-002: 1 hole insert • 2D3199-003: 1 hole insert • 2D3199-004: 1 hole insert • 2D3199-005: 1 hole insert • 2D3199-006: 1 hole insert • 2D3199-007: 1 hole insert • 2MFR526MAX5053: plastic marine case • 2TRMBAG-PYROS: Cordura® soft bag PYROS 140-1H INSERTS: Applications: ORDERING CODES: • PYROS 375: calibrator. • 2D3333: blank insert. • 2D3332: 4 holes insert. • 2D3331: 2 holes insert. • 2MFR526MAX5053: plastic marine case. • 2TRMBAG-PYROS: Cordura® soft bag. ORDERING CODES: • PYROS 650: calibrator. • 2D2927: blank insert. • 2D2928: 2 holes insert. • 2D2929: 1 hole insert. • 2D2930: 4 holes insert. • 2D3033: 3 holes insert. • 2D3034: 1 hole insert. • 2D3133: 4 holes insert. • 2MFR526MAX5053: plastic marine case. • 2TRMBAG-PYROS: Cordura® soft bag. Automatic computer-controlled calibrations. GIUSSANI S.r.l. Via dei Crederi, 411 24045 Fara Gera d’Adda (BG) - Italy Tel.: 0363/399019 - Fax.: 0363/398725 www.giussanionline.it [email protected] Control and calibration of temperature sensor, in the laboratory and in the field, in conformity with ISO 9000 standards CERTIFICATION: All instruments are supplied with final testing, stability and accuracy certification traceable to Accredia standards. These innovative calibrators have been designed for on-site applications and for the severe conditions of the naval and marine sectors. Their ease of use, compact and practical design, make them unbeatable in industrial processes where the verification of the temperature measurement systems is a key issue for the control of the process and the quality of the final product. Special attention was paid to reduce weight, size and to reinforce robustness by using an aluminium body and aluminium and stainless steel for many internal parts. Each calibrator is tested in our laboratory and calibrated with our measurement samples in accordance with the international standard. At this stage all the functions are checked against reference parameters and a calibration report is issued. The thermal part of these calibrators is made of a metal block heated with resistors or with Peltier thermoelectric modules. In the metal block there are one or more holes in which the interchangeable inserts are placed. The standard inserts available make the calibrators versatile in order to adapt them to the calibration of the temperature sensors with the most common diameters in use. It is also possible to create inserts with special holes upon request. The equipment provided as standard on each oven includes the power supply cable, the tweezers to extract the inserts, the connection cables of the thermostats, a fuse kit, one or more of the inserts most commonly used, the instructions manual

 Open the catalog to page 1
pyros-2

COMPARISON TABLE: PYROS PYROS 140 It covers a range from -24 to 140 °C. It has Technical specification Mean heating time (stabilization included) Mean cooling time (stabilization included) DRY BLOCK PORTABLE CALIBRATORS DNV® CERTIFIED Axial uniformity a stability of ±0,05 °C and a precision of ±0,25 °C. The time taken to reach -20 °C is just 17 DNV® CERTIFIED minutes and the time to reach 120 °C is just 20 minutes: this allows considerable savings in terms of time during calibration that requires more than one verification point. Hole depth The excellent performances of PYROS 140 Hole diameter...

 Open the catalog to page 2
pyros-3

COMPARISON TABLE: PYROS PYROS 140 It covers a range from -24 to 140 °C. It has Technical specification Mean heating time (stabilization included) Mean cooling time (stabilization included) DRY BLOCK PORTABLE CALIBRATORS DNV® CERTIFIED Axial uniformity a stability of ±0,05 °C and a precision of ±0,25 °C. The time taken to reach -20 °C is just 17 DNV® CERTIFIED minutes and the time to reach 120 °C is just 20 minutes: this allows considerable savings in terms of time during calibration that requires more than one verification point. Hole depth The excellent performances of PYROS 140 Hole diameter...

 Open the catalog to page 3
pyros-4

STANDARD EQUIPMENT: STANDARD EQUIPMENT: STANDARD EQUIPMENT: • Electric power cable. • Tweezers for insert removing. • Kit of fuses. • Thermostat connection cables. • Instructions manual. • Test report. • Electric power cable. • Tweezers for insert removing. • Kit of fuses. • Thermostat connection cables. • Instructions manual. • Test report. • Insert 2D3332. • Electric power cable. • Tweezers for insert removing. • Kit of fuses. • Thermostat connection cables. • Instructions manual. • Test report. • Insert 2D3133. PYROS140-1H: calibrator 1 hole • 2D3391: 4 holes insert • 2D3463: blank insert...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.