ENERGY TRANSMISSION LINES
22Pages

{{requestButtons}}

Catalog excerpts

ENERGY TRANSMISSION LINES - 1

ENERGY TRANSMISSION LINES www.giovenzana.com

Open the catalog to page 1
ENERGY TRANSMISSION LINES - 2

ENERGY TRANSMISSION LINES www.giovenzana.com PRODUCTS INDEX BUSBAR SYSTEM Line construction Busbar System LINE TYPE / AMPERAGE COVERAGE Technical Data - Busbar & Multipole System 40A LINE TYPE / AMPERAGE COVERAGE 40A Pre-Mounted Conductors Continuous conductors Max 5 Poles MULTIPOLE SYSTEM Pre-mounted conductors FESTOON SYSTEM Line construction Festoon System Continuous conductors Pre-mounted conductors Continuous conductors Stainless Steel Pre-mounted conductors 7 poles *Only 4 poles with parallel connections 22/23 24/25 Survey Busbar System LINE I-BEAM Accessories Busbar System 39 Light...

Open the catalog to page 2
ENERGY TRANSMISSION LINES - 3

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR BUSBAR SYSTEM AVAILABLE VERSIONS The busbar system conductors rails is modern and safe system for energy transmission for various types of equipment, such as, cranes, bridge cranes, conveyour belts, chain conveyors, etc... The busbar system complies with the relevant international standards ensuring safety of the operator, easy installation and reliability. The new “H” honeycomb profile of the TR85H line guarantees extra endurance and lightness. A. CONTINUOUS CONDUCTORS The conductors are pulled from a coil without joints into the already...

Open the catalog to page 3
ENERGY TRANSMISSION LINES - 4

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR SYSTEM LINE CONSTRUCTION CURRENT IN CONTINUOUS SERVICE To decide the size of trolleys it is necessary to consider: • Maximum current in service • Devices (cage motors, slip rings motors, resistors, electronic starters) • Starting current of the devices • Maximum ambient temperature • The distance between device to the nearest power feed • Voltage and admissible voltage drop in continuous and in starting service • Type of current • Devices cycle operations (load factor) Specify the number of the devices which work simultaneously to...

Open the catalog to page 4
ENERGY TRANSMISSION LINES - 5

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR SYSTEM TECHNICAL DATA Operating current 23°C Comply with standards Markings Rated operating voltage [Ue] Frequency Conditional short circuit withstand current Fuse rating gG Protection class CEI EN 60529 Flammability resistance of the busbar: UL94 Cei EN 60695-2-1 Ambient Temperature operating storage Max admissible trolley speed ETP Copper strip section [mm2] * The 200A and the 320A are obtained by parallel configuration, so only for 4 poles. The values indicated are referred to the single conductor. CONDUCTORS BARS WEIGHT TABLE (complete...

Open the catalog to page 5
ENERGY TRANSMISSION LINES - 6

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR SYSTEM CONTINUOUS CONDUCTORS Material: plastic. To connect two busbars. Material: plastic. Max support spacing: 1,33 m. For utilization with two trolleys in order to have ampacity of 50A. TR6001W DOUBLE TROLLEY SUPPORT TR6002W Fix the line to control thermal expansion. One for each line. FIXED POINT Material: steel. Max support spacing: 1,33 m. Alternative product of TR8557 (with TR8510). HANGER CLAMP CONDUCTOR SIZE Standard lenght: 4 meters*. Material: PVC. To use to move the trolley current collector. Material: plastic. Closes and...

Open the catalog to page 6
ENERGY TRANSMISSION LINES - 7

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR SYSTEM PRE-MOUNTED CONDUCTORS Standard lenght: 4 meters*. 4 conductors. Standard lenght: 4 meters*. 5 conductors. Conductor type. Included in busbar code 10x1 - 10mm2 Included in busbar code 10x1,5 - 15mm2 Material: plastic. To connect two busbars. Material: steel. Max support spacing: 1,33 m. HANGER CLAMP Material: plastic. Closes and protects the busbar end. Material: plastic. Max support spacing: 1,33 m. To use to move the trolley current collector. Alternative product of TR8557 (with TR8510). For utilization with two trolleys in order...

Open the catalog to page 7
ENERGY TRANSMISSION LINES - 8

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR SYSTEM CONTINUOUS CONDUCTORS ITEM CONDUCTOR SIZE HANGER CLAMP IN-LINE FEED Material: steel. To connect two busbars. To use to move the trolley current collector. Alternative product of TR8557 (with TR8510). For utilization with two trolleys in order to have ampacity of 140A. To fix the line to control thermal expansion 1 for each line. DOUBLE TROLLEY SUPPORT Material: plastic. Max support spacing: 1,33 m. FIXED POINT Material: steel. Max support spacing: 1,33 m. EXPANSION JOINT To use to compensate thermal expansion. INSPECTION JOINT To...

Open the catalog to page 8
ENERGY TRANSMISSION LINES - 9

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR SYSTEM PRE-MOUNTED CONDUCTORS ITEM Standard lenght: 4 meters*. 4 conductors. Standard lenght: 4 meters*. 5 conductors. To use to move the trolley current collector. Alternative product of TR8557 (with TR8510). DOUBLE TROLLEY SUPPORT For utilization with two trolleys in order to have ampacity of 140A. To fix the line to control thermal expansion. 1 for each line. Included in Busbar code Conductor type. HANGER CLAMP Material: plastic. To connect two busbars. Material: plastic. Max support spacing: 1,33 m. Material: steel. Max support...

Open the catalog to page 9
ENERGY TRANSMISSION LINES - 10

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR SYSTEM CONTINUOUS CONDUCTORS ITEM Material: plastic. To connect two busbars. FIXED POINT To fix the line to control thermal expansion. 1 for each line. TR85H7P03W Recommended use of dedicated accessories to page 23. To use to exctract the trolley from the line (when there are more than two trolleys). To use to section the line (double up the number of the trolleys). SECTION JOINT CONDUCTOR INSERTION TROLLEY For insertion of copper conductor in the line. INSPECTION JOINT TROLLEY CURRENT COLLECTOR To use to compensate thermal expansion. Only...

Open the catalog to page 10
ENERGY TRANSMISSION LINES - 11

ENERGY TRANSMISSION LINES www.giovenzana.com BUSBAR SYSTEM PRE-MOUNTED CONDUCTORS ITEM Standard lenght: 4 meters*. 4 conductors. Standard lenght: 4 meters. 7 conductors. Conductor type. HANGER CLAMP 4 POLES TROLLEY CONNECTION CLAMP SECTION JOINT To use to section the line (double up the number of the trolleys). To fix the line to control thermal expansion. 1 for each line. TROLLEY CURRENT COLLECTOR FIXED POINT Material: plastic. Closes and protects the busbar end. Material: steel. Max support spacing: 1 m. IN-LINE FEED Material: plastic. Max support spacing: 1 m. Included in busbar code...

Open the catalog to page 11