EN 81-20 / EN 81-50 RULES
20Pages

{{requestButtons}}

Catalog excerpts

EN 81-20 / EN 81-50 RULES - 2

Giovenzana International B.V.® Leader in the design and implementation of Safety Solutions for Elevators and Escalators, celebrates its 70 years on the market. Competence, reliability and customer care are our uniqueness. Our mission is «Safety First!» We offer both a wide range of standard and customized products for all types of installation with specifications that are up to date with the major European and international safety guidelines. 1952 2022 bulding the future Believe in our experience! Our growing portfolio of high-quality, innovative and competitive Elevator products includes:...

Open the catalog to page 2
EN 81-20 / EN 81-50 RULES - 3

Standard executions are accompanied by a wide range of special and customized executions according to customer specifications. On request, we can respond to the specific customers' needs designing, developing and testing special products. Giovenzana cultivated daily close synergies with its own customers to identify the right product which respond to the most different needs. ELEVATOR TECHNOLOGY

Open the catalog to page 3
EN 81-20 / EN 81-50 RULES - 4

Our wide range of GM SERIES maintenance control stations are fully compliant with the major European and international Elevator Standards all around the world. Its design incorporates the major rules: • • • • Mushroom emergency device in accordance with IEC/EN 60947-5-5; Mandatory run button; Protected operators against accidental impacts; Cam switch (not selector) binding to the norm for inspection operation with solid drive and without margin of error in the switching; Contact blocks with spring clamp conform to EN 60068-2-6 and EN 60068-2-27 and vibration resistant with IP20 degree of...

Open the catalog to page 4
EN 81-20 / EN 81-50 RULES - 5

The GM SERIES includes pit bottom stations, recall drive control units, inspection and maintenance stations. Compliance: EN81-20 / EN81-50, CSA-B44.1 / ASME-A17.5, GOST33984.1-2016, ABNT NBR 16858, EN ISO 13850. Functional Safety (IEC 61508): SIL1, SIL2, SIL3. Enclosure: made of self-extinguishing thermoplastic material. Protection class (EN 60529): NEMA 4X, IP65 without socket, IP54. Terminal connections: with socket IP20. Vibration resistance: EN 60068-2-26, EN 60069-2-27. Shock resistance: EN 600068-2-29. Connections: spring clamp contacts for push buttons, mushrooms, screws terminals...

Open the catalog to page 5
EN 81-20 / EN 81-50 RULES - 6

5. SAFETY REQUIREMENTS AND/OR PROTECTIVE MEASURES 5.2.1.5 Electric equipment in the pit and in machinery spaces and pulley rooms 5.2.1.5.1 There shall be in the pit: Stopping device(s) visible and accessible on opening the door(s) to the pit, and from the pit floor, in conformity with the requirements of 5.12.1.11; a permanently installed inspection control station according to 5.12.1.5 operable within 0,30 m of a refuge space; means to switch the well lighting (5.2.1.4.1), positioned within a maximum horizontal distance of 0,75 m from the pit access door frame inner edge and at a minimum...

Open the catalog to page 6
EN 81-20 / EN 81-50 RULES - 7

5.12.1.5 Control of inspection operation 5.12.1.5.1 Design requirements 5.12.1.5.1.1 To facilitate inspection and maintenance, a readily operable inspection control station shall be permanently installed: a) a switch (inspection operation switch) which shall satisfy the requirements for electric safety devices (5.11.2). This switch, which shall be bi-stable, shall be protected against involuntary operation; b) direction push buttons “UP” and “DOWN” protected against accidental operation with the direction of movement clearly indicated; The return to normal operation of the lift shall only...

Open the catalog to page 7
EN 81-20 / EN 81-50 RULES - 8

CAR ROOF MAINTENANCE CONTROL STATIONS 5.4.8 EQUIPMENT ON TOP OF THE CAR The following shall be installed on top of the car: a) control device in conformity with 5.12.1.5 (inspection operation) operable within 0,30 m horizontally from a refuge space (5.2.5.7.1); GM261 IP65 Compact vertical inspection box b) stopping device in conformity with 5.12.1.11, in an easily accessible position and no more than 1 m from the entry point for inspection or maintenance personnel. GM262 IP65 Compact horizontal inspection box This device may be the one located next to the inspection operation contro! if...

Open the catalog to page 8
EN 81-20 / EN 81-50 RULES - 9

CAR ROOF DEVICES WITH 5 LUX LED LIGHT 5.4 CAR, COUNTERWEIGHT AND BALANCING WEIGHT 5.4.10 LIGHTING 5.4.10.4 There shall be emergency lights with an automatically rechargeable emergency supply, which is capable of ensuring a lighting intensity of at least 5 LUX for 1 h: a) at each alarm initiation device in the car and on the car roof; b) in the centre of the car 1 m above the floor; c) in the centre of the car roof, 1 m above the floor. Maintenance station with 5 LUX white light and hole plug Maintenance station with 5 LUX white light and alarm button This lighting shall come on...

Open the catalog to page 9
EN 81-20 / EN 81-50 RULES - 10

MAINTENANCE STATION WITH 50/5 LUX LED LIGHT 5.2 WELL, MACHINERY SPACES AND PULLEY ROOMS 5.2.1.4 LIGHTING 5.2.1.4.1 The well shall be provided with permanently installed electric lighting, giving the following intensity of illumination, even when all doors are closed, at any position of the car throughout its travel in the well: a) at least 50 lux, 1 m above the car roof within its vertical projection; b) at least 50 lux, 1 m above the pit floor everywhere a person can stand, work and/or move between the working areas; c) at least 20 lux outside of the locations defined in a) and b),...

Open the catalog to page 10
EN 81-20 / EN 81-50 RULES - 11

PRE-WIRED SILICONE LED STRIPS 5.2 WELL, MACHINERY SPACES AND PULLEY ROOMS 5.2.1.4 LIGHTING 5.2.1.4.2 1. STRIP LED COIL OF THE CHOSEN LENGTH Strip LED coin is available in different lengths as the table below. Available in two different versions: GSL30 and GSL60. Machinery spaces and pulley rooms shall be provided with permanently installed electric lighting with an intensity of at least 200 LUX at floor level everywhere a person needs to work and 50 LUX at floor level to move between working areas. The supply for this lighting shall be in conformity with 5.10.7.1. 2. POWER SUPPLY CABLE The...

Open the catalog to page 11
EN 81-20 / EN 81-50 RULES - 12

5.12.1.5 Control of inspection operation 5.12.1.5.1 Design requirements 5.12.1.5.1.2 The inspection control station shall consist of: a) a switch (inspection operation switch) which shall satisfy the requirements for electric safety devices (5.11.2). This switch, which shall be bi-stable, shall be protected against involuntary operation; b) direction push buttons “UP” and “DOWN” protected against accidental operation with the direction of movement clearly indicated; c) a push button “RUN” protected against accidental operation; d) a stopping device in conformity with 5.12.1.11. The control...

Open the catalog to page 12