X1-PCBC - 1

Product tags: Optometer Gigahertz-Optik GmbH

Open the catalog to page 1
X1-PCBC - 2

Description System Integration Meter The X1-PCBC is a remote-control-only variant of the X1 hand held meter. Three models X1-PCBCL, X1-PCBCL-PM and X1-PCBCL-RM are offered in aluminum box style housing for panel or rack mount. Simple to Use Operating the X1 is simple. The meter set-up is supported by an easy to use menu. The menu allows selection of the operating mode, the detector and measurement parameter. Once set-up all settings are stored and recalled on next power-up unless reinitialized. Measurement values are displayed in absolute quantities for the particular detector connected....

Open the catalog to page 2
X1-PCBC - 3

Detector interface Measurement ranges Seven (200μA to 200.0pA) manual or auto range Offset correction Correction range transcending Parameter adjustment Remote control or front panel buttons (menu), set values permanently stored (eeprom) Calibration information Max. 256 Datasets stored in Eeprom LCD graphic display 97x32 pixel Display area 14.3mm x 35.8mm Switchable LED-backlight Text display 4 rows each 14 characters Configurable with Produktname VL-3701 Product Image Show product Detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.5...

Open the catalog to page 3
X1-PCBC - 4

Product Image Show product High sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration Very high sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 28nA/lx, no diffuser, for the usage with optometers and amplifiers, calibration Module detector head for the measurement of photopic illuminance in Lux [lx]. Very high sensitive illuminance detector head for spotlamps Features: UMPA adapter for usage with integrating...

Open the catalog to page 4
X1-PCBC - 5

Product Image Show product PD-9310A measurement head with GB-GD-360 photogoniometer for measurement of the luminous intensity distribution of 2π spot lamps and LEDs. Goniometer bench with adjustable measurement distance of up to 2000 mm. PD-9310A photometric detector corresponding to the DIN 5032 quality class A. Calibration certificate conformng to the ISO 17025 specifications. For use with all optometers and signal amplifiers from Gigahertz-Optik GmbH. Detector head for the measurement of irradiance in W/m². Features: spectral responsivity from 400-500nm (BLUE), cosine field-of-view, for...

Open the catalog to page 5
X1-PCBC - 6

Product Image Show product Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 200/250-280nm (UV-C), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 320-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 280-320nm...

Open the catalog to page 6
X1-PCBC - 7

Product Image Show product Detector head for the measurement of high irradiance of UV-C 254nm radiation in W/m². Features: pre-aging for long time stability, cosine field-of-view, metal shielded cable, for the usage with optometers and amplifiers, calibration certificate. Detector for the measurement of UV-C 254 nm irradiance in air disinfection applications Features: wide dynamic range for UV hazard and effective irradiance, wide angle cosine F.O.V. for straylight measurements, for the usage with optometers, calibration certificate. Detector head for high intensity irradiation as in UV or...

Open the catalog to page 7
X1-PCBC - 8

Product Image Show product Detector for Blue-light hazard measurements. Features: Single-cell detector, BLH actinic irradiance, for the use with optometer, calibration certificate Detector for the measurement of UV-C 254 nm irradiance in air disinfection applications Features: wide dynamic range for UV hazard and effective irradiance, wide angle cosine F.O.V. for straylight measurements, for the usage with optometers, calibration certificate. Detector heads to measure the irradiance in W/m² and the radiance in W/(m²*sr). Features: front lenses with 1°, 2° or 5° viewing angle, for the usage...

Open the catalog to page 8
X1-PCBC - 9

Description Accessories Adapter cable (2m) to connect light detectors with -1 BNC connector to the -4 Adapter to connect up to four detectors with BNC connector to X1 Adapter cable 12inch with ITT (-4) connector for X1. Al box with -4 socket Adapter cable to connect light detectors with -2 calibration data connector to the ITT (-4) socket of the optometer X1 1. Cable length 0.2 m. Hard case for meter and accessories Hard case for meter and accessories Hard case for meter and accessories Hard case for meter and accessories Hard case for meter and accessories Gigahertz-Optik GmbH

Open the catalog to page 9
X1-PCBC - 10

Contact Person Gigahertz-Optik GmbH Tel. +49 (0)8193-93700-0 Fax +49 (0)8193-93700-50 info@gigahertz-optik.de Gigahertz-Optik GmbH Powered by TCPDF (www.tcpdf.org)

Open the catalog to page 10

All Gigahertz Optik GmbH catalogs and technical brochures

  1. ISD-5-Si

    5 Pages

  2. XD-9510

    4 Pages

  3. XD-9509

    4 Pages

  4. X1-UV-3727

    6 Pages

  5. X1

    17 Pages

  6. BTS256-PAR

    8 Pages

  7. ISS-30-VA

    5 Pages

  8. ISS-8P-VAHP

    5 Pages

  9. PLL-1701

    5 Pages

  10. TPI21-TH

    5 Pages

  11. UPB-150-ART

    9 Pages

  12. UPB-150-ARTA

    10 Pages

  13. UPG-150-ART

    9 Pages

  14. VL-3704

    5 Pages

  15. BN-9101

    5 Pages

  16. BTS2048-UV-S

    8 Pages

  17. CSS-45

    7 Pages

  18. ISS-17-VA

    5 Pages

  19. TFCT25

    4 Pages

  20. P-9802

    12 Pages

  21. LDM-9811

    6 Pages

  22. PS-3702

    4 Pages

  23. TP-4501

    4 Pages

  24. UV-3709

    5 Pages

  25. XD-45-ERYC

    5 Pages

  26. XD-45-HUV

    4 Pages

  27. ISD-0.8-SiLP

    4 Pages

  28. ISD-30-Si

    5 Pages

  29. ISD-3P-Si

    7 Pages

  30. ISD-5P-SiUV

    5 Pages

  31. XD-9506

    5 Pages

  32. RCH-005

    6 Pages

  33. RCH-014

    6 Pages

  34. RCH-115

    6 Pages

  35. RCH-116

    6 Pages

  36. RW-3708

    6 Pages

  37. UV-3711-308

    5 Pages

  38. UV-3725

    6 Pages

  39. ISD-15P-VL

    6 Pages

  40. ISD-5-VL

    5 Pages

  41. LDM-9901

    7 Pages

  42. PD-9310A

    6 Pages

  43. VL-3701

    6 Pages

  44. CT-4501

    5 Pages

  45. P-9202-6

    6 Pages

  46. P-9801

    15 Pages

  47. P-2000

    17 Pages

  48. P-9710

    17 Pages

  49. X1-4

    7 Pages

  50. X1-RM

    10 Pages

  51. X1-3

    6 Pages

  52. BTS2048-VL

    11 Pages

  53. BTS256-EF

    9 Pages

  54. BTS256-E

    8 Pages

  55. MSC15

    7 Pages

  56. LS-OK30

    4 Pages

  57. LP-9910

    4 Pages

  58. LH-xxF

    4 Pages

  59. ISD-10-VL

    7 Pages

Archived catalogs

  1. BTS256-PAR

    9 Pages