P-9710 - 1

Product tags: Optometer , Industrial Applications , Dosimeter , Flash measurement , Blondel-Rey , Broadband-meter Gigahertz-Optik GmbH

Open the catalog to page 1
P-9710 - 2

Description P-9710-1 – Multi-functional light meter for highquality photometric measurements The P-9710-1 optometer is a high-quality device designed by GigahertzOptik for mobile use. Its signal amplifier provides a wide dynamic range for the detectors’ signal currents ranging up to 2 mA. The noise-equivalent current signal is as low as 0.1 pA. The device has eight gain ranges that can be manually or automatically selected for adjustment to match the signal levels. Variable integration time One of the characteristic properties of the P-9710-1 optometer is the short integration time of the...

Open the catalog to page 2
P-9710 - 3

Light measurements and light analysis The P-9710-1 optometer has eighteen different measurement modes that can easily be selected using a user-friendly menu hence enabling its multifunctional application. P-9710-2 – Optometer for dose measurement of short pulses using the pulse stretching method Unlike the P-9710-1, the P-9710-2 optometer has a 20 ms standard time constant in all eight gain ranges. Thus light pulses shorter than 1 ns are stretched to 20 ms. The pulse energy of the stretched pulse can then be measured precisely with the 100 µs sample rate of the optometer. P-9710-4 –...

Open the catalog to page 3
P-9710 - 4

Measurement ranges range (A / V) gain error ± offset error (at 20 °C) gain (A / V) analogue output Measurement range detector head The optometer P-9710-1, P-9710-2 and P-9710-4 can be combined with all single-channel detector heads from Gigahertz-Optik. The typical responsivities of the detectors in A/W, A/lx, etc. are specified in the corresponding specifications. These specifications can be used to calculate the measurement ranges of the measurement heads in connection with the P-9710-1, P-9710-2 and P-9710-4 optometer as described below: The measurement range of a light meter comprising...

Open the catalog to page 4
P-9710 - 5

Measurement modes The product has eighteen different measurement modes that can easily be selected using a userfriendly menu hence enabling its multifunctional application. CW CW Maximum CW Minimum Peak Maximum Peak Minimum Peak to Peak I Pulse energy Relative (%) Relative (Log) Relative (Fact.) Hold CW Level Check Continuous measurements in the measurement interval of the selected integration time. Display of the current CW measurement value and the maximum CW value attained. Display of the current CW measurement value and the minimum CW value attained. Display of the current CW average...

Open the catalog to page 5
P-9710 - 6

Offset correction Exceeding correction range Measurement parameter setup Via RS232 or using control panel on the front side. Settings are permanently saved (EEPROM). Ten different settings can be saved Data logger Max. 12288 entries, permanently saved in flash memory Miscellaneous Dimensions / Weight RS232 (9600 baud, 8 data bits, 1 stop bit, no parity) Plug: TRIAD01 (Tyco) Voltage supply Rechargeable battery, battery capacity: 6 V, 0.5 Ah Operation time: 5 hours with display backlight switched on, 12 hours with display backlight switched off 5.5 mm / 2.5 mm / 9.5 mm socket for plug-in...

Open the catalog to page 6
P-9710 - 7

Product Image Show product Detector head for the measurement of scotopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.2nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate High sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration certificate High sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and...

Open the catalog to page 7
P-9710 - 8

Product Image Show product Integrating sphere detector for luminous flux (lm) of 2π spot sources. Features: 100mm dia, BaSO4 coating, 25.4mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 150mm dia, BaSO4 coating, 38.1mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 150mm dia, synthetic coating, 38.1mm dia port, for the usage with optometers and signal...

Open the catalog to page 8
P-9710 - 9

Product Image Show product Integrating sphere detector for luminous flux (lm) of 2π and 4π sources. Features: 500mm dia, BaSO4 coating, sphere to open, auxiliary lamp, for the usage with optometers and signal amplifiers, Calibration certificate VL-1101 module light detectors with photometric V(λ) responsivity Photometric detector head with DP-11 mount. Photometric detector head with M30x1 mount. Features: modular detector for use with integrating spheres, front lenses etc. For use with optometers and signal amplifiers Features: modular detector for use MD-37, SRT and other accessories. For...

Open the catalog to page 9
P-9710 - 10

Product Image Show product Detector head for the measurement of irradiance in W/m². Features: spectral responsivity from 400-800nm (VIS), cosine fieldof-view, for the usage with optometers and amplifiers, calibration certificate Detector head for the measurement of irradiance in W/m². Features: spectral responsivity from 800-1000nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate Detector head for the measurement of irradiance in W/m². Features: spectral responsivity from 400-1000nm (VISNIR), cosine field-of-view, for the usage with...

Open the catalog to page 10
P-9710 - 11

Product Image Show product Integrating sphere detector with short rise time for Laser power in W. Features: 8mm dia, ODM98 coating, 400-1100nm responsivity, optional SMA Adapter, for the usage with fast optometers and signal amplifiers, Calibration certificate Integrating sphere detector for Laser power in W. Features: 16mm dia, 3mm dia port, BaSO4 coating, 400-1100nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for Laser power in W. Features: 30mm dia, 5mm dia port, synthetic ODM98 coating, 400-1100nm responsivity,...

Open the catalog to page 11

All Gigahertz Optik GmbH catalogs and technical brochures

  1. ISD-5-Si

    5 Pages

  2. XD-9510

    4 Pages

  3. XD-9509

    4 Pages

  4. X1-UV-3727

    6 Pages

  5. X1

    17 Pages

  6. BTS256-PAR

    8 Pages

  7. ISS-30-VA

    5 Pages

  8. ISS-8P-VAHP

    5 Pages

  9. PLL-1701

    5 Pages

  10. TPI21-TH

    5 Pages

  11. UPB-150-ART

    9 Pages

  12. UPB-150-ARTA

    10 Pages

  13. UPG-150-ART

    9 Pages

  14. VL-3704

    5 Pages

  15. BN-9101

    5 Pages

  16. BTS2048-UV-S

    8 Pages

  17. CSS-45

    7 Pages

  18. ISS-17-VA

    5 Pages

  19. TFCT25

    4 Pages

  20. P-9802

    12 Pages

  21. LDM-9811

    6 Pages

  22. PS-3702

    4 Pages

  23. TP-4501

    4 Pages

  24. UV-3709

    5 Pages

  25. XD-45-ERYC

    5 Pages

  26. XD-45-HUV

    4 Pages

  27. ISD-0.8-SiLP

    4 Pages

  28. ISD-30-Si

    5 Pages

  29. ISD-3P-Si

    7 Pages

  30. ISD-5P-SiUV

    5 Pages

  31. XD-9506

    5 Pages

  32. RCH-005

    6 Pages

  33. RCH-014

    6 Pages

  34. RCH-115

    6 Pages

  35. RCH-116

    6 Pages

  36. RW-3708

    6 Pages

  37. UV-3711-308

    5 Pages

  38. UV-3725

    6 Pages

  39. ISD-15P-VL

    6 Pages

  40. ISD-5-VL

    5 Pages

  41. LDM-9901

    7 Pages

  42. PD-9310A

    6 Pages

  43. VL-3701

    6 Pages

  44. CT-4501

    5 Pages

  45. P-9202-6

    6 Pages

  46. P-9801

    15 Pages

  47. P-2000

    17 Pages

  48. X1-4

    7 Pages

  49. X1-PCBC

    10 Pages

  50. X1-RM

    10 Pages

  51. X1-3

    6 Pages

  52. BTS2048-VL

    11 Pages

  53. BTS256-EF

    9 Pages

  54. BTS256-E

    8 Pages

  55. MSC15

    7 Pages

  56. LS-OK30

    4 Pages

  57. LP-9910

    4 Pages

  58. LH-xxF

    4 Pages

  59. ISD-10-VL

    7 Pages

Archived catalogs

  1. BTS256-PAR

    9 Pages