Open the catalog to page 1Description Hand-held Meter The X1 optometer is one of the most versatile hand-held light measurement instruments available. It combines a powerful electronic design packaged in a light-weight ergonomic housing. Its compact size makes it ideal for field service applications. A unique feature of the X1 is its capability to operate detector heads housing up to four photodiodes with all four signals displayed on the four line display with on/off backlighting. Operating the X1 is simple. The meter set-up is supported by an easy to use menu. The menu allows selection of the operating mode, the...
Open the catalog to page 2Multipurpose Light Measurement Instrument The X1 can be combined with most of the Gigahertz-Optik single cell or multi cell light detector heads for use in a wide application range of radiometric, photometric and colorimetric measurements Interfaces The X1 features a USB interfaces. Specifications General Short description Optometer for the individual configuration as photometer, RGB-luminous Color meter, Radiometer, UVradiometer, LASER-powermeter etc. with the detector heads supplied. Main features Compact gauge in ergonomic design for one Hand control. Four measurement chanels in...
Open the catalog to page 3*) The measurement uncertainty is usually below the calibration uncertainty, but must also be considered. At very low currents, a detailed examination of the measurement uncertainty analysis is recommended, because in this case the measurement uncertainty can predominate. **) internal zero adjustment can reduce the bias current. Maximum zero adjusted bias current = ±0,2pA. ***) only for instrument versions with 7 measuring ranges ****) valid for currents above 10pA CW integration time sampling rate internal sampling rate ADC 250 µs Offset correction Correction range transcending Parameter...
Open the catalog to page 4Menu guide Menu item 1. Mode 3. Detector 4. Offset 5. Range Function Measures respective of any offset and calibration factors programmed Dose Accumulates the single readings as exposure for measured quantity CIE Yxy & T Measures the CIE Color Values Yxy and T CIE Yuv & T Measures the CIE Color Values Yuv and T Zero Adjust Performs a zero adjustment of the internal amplifier and ADC Integration Sets the measurement (integration) time Dose Time Sets max. dose measurement time Selects calibration data to calculate the measurement result Performs an automatic offset adjustment ("Offset = CW"...
Open the catalog to page 5Product Name Detector head to measure Laser radiant power in W and Laser irradiance in W/m² Detector head for the measurement of photopic illuminance in Lux [lx] Detector head for the measurement of photopic illuminance in Lux [lx]. Class B, f1 ≤ 6 % Detector head for the measurement of photopic illuminance in Lux [lx] Detector head for the measurement of scotopic illuminance in Lux [lx] High sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration certificate High...
Open the catalog to page 6Product Name RGB detector head for photopic illuminance and luminous color. Features: four sensor design, xy, u’v’, CCT, for the usage with X1 and P-9801 Optometer, part of HCT-99D, calibration certificate, for polychromatic light, Detector head to measure the photopic spot luminance in cd/m². Features: selectable 20', 1° and 6° viewing angles, view finder, focus able achromatic lens, for the usage with Optometers and amplifiers, calibration certificate. Photometric detector head with VL-11 mount. Features: modular detector for use with integrating spheres, front lenses etc. For use with...
Open the catalog to page 7Product Name Integrating sphere detector for luminous flux (lm) of 2π sources Photometric, temperature stabilized detector with DP-11 mount Detector head for the measurement of irradiance in W/m² Detector head for the measurement of irradiance in W/m² Detector head for the measurement of irradiance in W/m² Detector head for the measurement of irradiance in W/m² Detector head for the measurement of irradiance in W/m² Detector head for the measurement of irradiance in W/m² Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 315-400nm...
Open the catalog to page 8Product Name Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 320-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 280-320nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 305-400nm (UV-A), cosine...
Open the catalog to page 9Product Name Detector head to measure irradiance W/m² in Bilirubin phototherapy. Features: Bilirubin actinic responsivity, cosine fieldof-view, for usewith optometers, calibration certificate. Detector head for the measurement of irradiance of 308nm Eximer Lasers in W/m². Features: flat spectral responsivity besite 308nm. cosine field-of-view, dose measurement in conjuntion with P-9710 optometer, calibration certificate Detector for Blue-light hazard measurements. Features: Singlecell detector, BLH actinic irradiance, for the use with optometer, calibration certificate Detector for the...
Open the catalog to page 10Product Name Detector head for high intensity irradiation in UV wide range curing processes Detector Head for High-Intensity Irradiation in UV-A Curing Processes Detector Head for High-Intensity Irradiation in Blue Light Curing Processes Detector head for high intensity irradiation in UV H-type light curing processes. Detector head for high intensity irradiation in UVA peak light curing processes. Detector head for high intensity irradiation in blue light curing processes. Irradiance Detector for UV or Blue light curing processes Detector head for high intensity irradiation in UV or blue...
Open the catalog to page 11All Gigahertz Optik GmbH catalogs and technical brochures
-
ISD-5-Si
5 Pages
-
XD-9510
4 Pages
-
XD-9509
4 Pages
-
X1-UV-3727
6 Pages
-
BN-LHSF-2P-20
5 Pages
-
BTS256-LED Plus Concept
7 Pages
-
BTS256-PAR
8 Pages
-
ISS-30-VA
5 Pages
-
ISS-8P-RVA-ROD
6 Pages
-
ISS-8P-VAHP
5 Pages
-
LCRT-2005-S+850
6 Pages
-
PLL-1701
5 Pages
-
TPI21-TH
5 Pages
-
UPB-150-ART
9 Pages
-
UPB-150-ARTA
10 Pages
-
UPG-150-ART
9 Pages
-
VL-3704
5 Pages
-
BN-9101
5 Pages
-
BTS2048-UV-S
8 Pages
-
BTS2048-UV-S-WP
8 Pages
-
CSS-45
7 Pages
-
ISS-17-VA
5 Pages
-
X1-1-RCH-116-4
3 Pages
-
TFCT25
4 Pages
-
UV-37 with SRT-M37-L-UV
5 Pages
-
P-9802
12 Pages
-
LDM-9811
6 Pages
-
PS-3702
4 Pages
-
TP-4501
4 Pages
-
UV-3709
5 Pages
-
XD-45-ERYC
5 Pages
-
XD-45-HUV
4 Pages
-
ISD-0.8-SiLP
4 Pages
-
ISD-30-Si
5 Pages
-
ISD-3P-Si
7 Pages
-
ISD-5P-SiUV
5 Pages
-
RW-37 with SRT-M37-L
5 Pages
-
XD-9506
5 Pages
-
RCH-005
6 Pages
-
RCH-014
6 Pages
-
RCH-115
6 Pages
-
RCH-116
6 Pages
-
RW-3708
6 Pages
-
UV-3711-308
5 Pages
-
UV-3725
6 Pages
-
ISD-15P-VL
6 Pages
-
ISD-5-VL
5 Pages
-
LDM-9901
7 Pages
-
PD-9310A
6 Pages
-
VL-3701
6 Pages
-
CT-4501
5 Pages
-
P-9202-6
6 Pages
-
P-9801
15 Pages
-
P-2000
17 Pages
-
P-9710
17 Pages
-
X1-4
7 Pages
-
X1-PCBC
10 Pages
-
X1-RM
10 Pages
-
X1-3
6 Pages
-
BTS2048-VL
11 Pages
-
BTS256-EF
9 Pages
-
BTS256-E
8 Pages
-
MSC15
7 Pages
-
LS-OK30
4 Pages
-
LP-9910
4 Pages
-
LH-xxF
4 Pages
-
ISD-10-VL
7 Pages
-
Catalogue complete
198 Pages
Archived catalogs
-
BTS256-PAR
9 Pages