Product tags: Multi-Channel , Handheld device , Gigahertz Optik GmbH
Open the catalog to page 1Description Hand-held Meter The X1 optometer is one of the most versatile hand-held light measurement instruments available. It combines a powerful electronic design packaged in a light-weight ergonomic housing. Its compact size makes it ideal for field service applications. A unique feature of the X1 is its capability to operate detector heads housing up to four photodiodes with all four signals displayed on the four line display with on/off backlighting. Handheld optometer Operating the X1 is simple. The meter set-up is supported by an easy to use menu. The menu allows selection of the operating...
Open the catalog to page 2Multipurpose Light Measurement Instrument The X1 can be combined with most of the Gigahertz-Optik single cell or multi cell light detector heads for use in a wide application range of radiometric, photometric and colorimetric measurements Interfaces The X1 features a USB interfaces. Specifications General Short description Optometer for the individual configuration as photometer, RGB-luminous Color meter, Radiometer, UVradiometer, LASER-powermeter etc. with the detector heads supplied. Main features Compact gauge in ergonomic design for one Hand control. Four measurement chanels in multiplex...
Open the catalog to page 3*) The measurement uncertainty is usually below the calibration uncertainty, but must also be considered. At very low currents, a detailed examination of the measurement uncertainty analysis is recommended, because in this case the measurement uncertainty can predominate. **) internal zero adjustment can reduce the bias current. Maximum zero adjusted bias current = ±0,2pA. ***) only for instrument versions with 7 measuring ranges ****) valid for currents above 10pA CW integration time Sampling rate internal sampling rate ADC 250 µs Offset correction Correction range transcending Parameter adjustment...
Open the catalog to page 4Menu guide Menu item 1. Mode Measures respective of any offset and calibration factors programmed Accumulates the single readings as exposure for measured quantity Measures the CIE Color Values Yxy and T Measures the CIE Color Values Yuv and T Performs a zero adjustment of the internal amplifier and ADC Sets the measurement (integration) time Sets max. dose measurement time CIE Yxy & T CIE Yuv & T Zero Adjust Integration Dose Time Selects calibration data to calculate the measurement result Performs an automatic offset adjustment ("Offset = CW" or "Offset = 0") Sets the measurement range (auto,...
Open the catalog to page 5Product Name Detector head for the measurement of photopic illuminance in Lux [lx] Detector head for the measurement of photopic illuminance in Lux [lx]. Class B, f1' ≤ 6 % Detector head for the measurement of photopic illuminance in Lux [lx] Detector head for the measurement of scotopic illuminance in Lux [lx] High sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration certificate High sensitive detector head for the measurement of photopic illuminance in Lux [lx]....
Open the catalog to page 6Product Name Detector head to measure the photopic spot luminance in cd/m². Features: selectable 20', 1° and 6° viewing angles, view finder, focus able achromatic lens, for the usage with Optometers and amplifiers, calibration certificate. Photometric detector head with VL-11 mount. Features: modular detector for use with integrating spheres, front lenses etc. For use with optometers and signal amplifiers Detector head to measure the photopic spot luminance in cd/m² Software Development Kit for X20 variants (X1 and HCT99). Application software for X1 variants. Module detector head for the measurement...
Open the catalog to page 7Product Name Photometric, temperature stabilized detector with DP-11 mount Detector head for the measurement of irradiance in W/m² in the spectral range 400 nm - 500 nm (BLUE). Detector head for the measurement of irradiance in W/m² in the spectral range 700 nm - 800 nm (RED). Detector head for the measurement of irradiance in W/m² in the spectral range 400 nm - 800 nm (VIS). Detector head for the measurement of irradiance in W/m² in the spectral range 800 nm - 1000nm (NIR). Detector head for the measurement of irradiance in W/m² in the spectral range 400 nm - 1000 nm (VISNIR). Detector head...
Open the catalog to page 8Product Name Detector head for the measurement of irradiance of UV radiation in W/m² in the spectral range 280 nm - 320 nm (UV-B). Detector head for the measurement of irradiance of UV radiation in W/m² in the range from 305 nm to 400 nm (UV-A). Detector head for the measurement of irradiance of UV radiation in W/m² in the spectral range from 315 nm to 400 nm with low crosstalk from radiation above 400 nm (UV-A). Detector head for the measurement of irradiance of UV radiation in W/m² in the spectral range 250 nm to 400 nm Detector head for the measurement of irradiance of UV radiation in W/m²....
Open the catalog to page 9Product Name Detector for Blue-light hazard irradiance measurements. Detector for the measurement of UV-C 254 nm irradiance in air disinfection applications ISD-3P-IGA Laser Power Detector Integrating sphere detector with InGaAs photodiode and 30 mm sphere for Laser power in W. ISD-5-Si Laser Power Detector Integrating sphere detector for Laser power in W Detector head for high intensity irradiation in UVA and blue light curing processes with rigid fiber Detector head with rigid fiber for high intensity UV and BLUE LED sources. ISD-5P-Si Laser Power Detector Integrating sphere detector for Laser...
Open the catalog to page 10Product Name Detector Head for High-Intensity Irradiation in Blue Light Curing Processes Detector head for high intensity irradiation in UV H-type light curing processes. Detector head for high intensity irradiation in UVA peak light curing processes. Detector head for high intensity irradiation in blue light curing processes. Irradiance Detector for UV or Blue light curing processes Detector head for high intensity irradiation in UV or blue light curing processes. Features: Separate light integrator and detector with flexible fiber coupling, 400nm+436nm BLUE responsivity, wide viewing angle,...
Open the catalog to page 116 Pages
7 Pages
6 Pages
9 Pages
11 Pages
11 Pages
7 Pages
7 Pages
9 Pages
15 Pages
14 Pages
5 Pages
9 Pages
11 Pages
11 Pages
5 Pages
5 Pages
4 Pages
4 Pages
6 Pages
12 Pages
5 Pages
4 Pages
3 Pages
5 Pages
7 Pages
6 Pages
5 Pages
6 Pages
6 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
4 Pages
4 Pages
6 Pages
17 Pages
17 Pages
15 Pages
6 Pages
5 Pages
6 Pages
6 Pages
7 Pages
5 Pages
6 Pages
5 Pages
7 Pages
7 Pages
8 Pages
8 Pages
5 Pages
5 Pages
9 Pages
10 Pages
9 Pages
5 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
7 Pages
5 Pages
17 Pages
6 Pages
4 Pages
4 Pages
5 Pages
17 Pages
2 Pages
10 Pages
10 Pages
6 Pages
11 Pages
9 Pages
8 Pages
7 Pages
4 Pages
4 Pages
4 Pages
7 Pages
198 Pages
8 Pages
9 Pages