Gigahertz Optik GmbH
Open the catalog to page 1Illuminance is the most frequently made measurement within general and specialist lighting applications. The two most important qualities required of a high precision illuminance detector are a spectral responsivity that is very well matched to the ideal V(λ) photopic curve and a spatial response that provides cosine correction. The VL-3701 meets the high standards of DIN Class A classification for both these parameters. Photometric detectors offer a convenient solution for measuring illuminance (lux) simply, quickly and over a very wide dynamic range. When Photometric detector for precise illuminance...
Open the catalog to page 2The robust detector housing is made of aluminum and offers a 2 m long, highly flexible connection cable. The threaded hole on the side or the circumferential V-groove on the front side enable the detector to be securely attached and enable it to be used with front tubes and optics. The detector’s low profile of only 20 mm allows its use even in restricted spaces. The detector can also be offered in a splash-proof version. Calibration Meaningful measurements in absolute units such as illuminance in lx require the calibration of a measuring device with traceability to National Metrology Institute...
Open the catalog to page 3Measurement ranges Maximum illuminance e.g. in connection with P-9710 (1 mA max): 2,000,000 lx, resolution with P-9710: 2 mlx Maximum illuminance e.g. in connection with X-1 (200 µA max): 400,000 lx Typical applications Measurement of illuminance in general and special lighting. Measurement tasks accompanying production. Calibration of illuminance sensitivity in A / lx. Calibration of the relative spectral responsivity. Calibration Calibration uncertainty Specification Spectral responsivity Typical responsivity Input optics f2 (directional response/cosine error) coaxial cable 2m Long, with BNC...
Open the catalog to page 4f2 (directional response/cosine error) Options Accessories WQ: Optional waterproof retrofitting of the VL-3701 detector using quartz dome and o-ring reinforcement of the base plate. Downloads Type Gigahertz Optik GmbH
Open the catalog to page 5Light measurement solutions for general and specialized lighting Configurable with Product Name High-End Optometer for Measurement of CW-, Single Pulse and Modulated Radiation Goniometer for the measurement of 2π sources Four-Channel USB Optometer, Respectively Current Amplifier, Designed for Photometric and Radiometric Detectors for MobileUse Optometer in 3HE Housing for use in 19” Racks Optometer respectively Current Amplifier Module with 4 Input Channels and 7 Gain Ranges Optometer module with 4 channels based on X1 technologie High-Speed and Short Rise Time Data Logger Optometer (Transient...
Open the catalog to page 6Product Name Product Image 8-Channel High Class Current Amplifier/Optometer Two-Channel Optometer Detector ports for the hollow spheres of the UM series modular construction integrating spheres. Features: Mounts for attaching detectors, fiber optic connectors and fiber pipes. Fast response time trans-impedance signal amplifier Universal trans-impedance signal amplifier Highly sensitive trans-impedance signal amplifier High-speed dual input optometer for measurement of CW, modulated radiation and optical fibers in W Multi-Purpose Touchscreen Optometer for Measurement of CW-, Single Pulse and Modulated...
Open the catalog to page 7Detector head with –2 connector, protective cap, calibration certificate Detector head with –4 connector, protective cap, calibration certificate Detector with –5 connector, protective cap, calibration certificate Calibration, calibration certificate Simulated calibration correction factors for visible LED sources out of the Gigahertz-Optik GmbH lamp emission spectrum database. Monochromatic LEDs in 10nm steps and white LEDs. Option: DIN EN ISO/IEC 17025:2018 Test Certificate (DAkkS) Illuminance responsivity according to standard CIE 210:2014. In combination with P-9710 optometer. 15311941 Option:...
Open the catalog to page 8We are known worldwide for excellent technical consulting and after sales support. Contact us to find together the best solution for you. Our services: • Technical Consulting & Sales • After-Sales Support • Calibrations & Re-Calibrations (ISO/IEC 17025 Calibration Services, factory calibration, Calibration of Third-Party Products) • Repairs & Updates • OEM & Feasibility Consulting of Customized Solutions Send us your inquiry or contact us by phone or e-mail. We would welcome your feedback too or review us on Google. An der Kaelberweide 12 82299 Tuerkenfeld, Germany Boston North Technology Park...
Open the catalog to page 96 Pages
7 Pages
6 Pages
9 Pages
11 Pages
11 Pages
7 Pages
7 Pages
9 Pages
15 Pages
14 Pages
5 Pages
17 Pages
11 Pages
11 Pages
5 Pages
5 Pages
4 Pages
4 Pages
6 Pages
12 Pages
5 Pages
4 Pages
3 Pages
5 Pages
7 Pages
6 Pages
5 Pages
6 Pages
6 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
4 Pages
4 Pages
6 Pages
17 Pages
17 Pages
15 Pages
6 Pages
5 Pages
6 Pages
6 Pages
7 Pages
5 Pages
6 Pages
5 Pages
7 Pages
7 Pages
8 Pages
8 Pages
5 Pages
5 Pages
9 Pages
10 Pages
9 Pages
5 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
7 Pages
5 Pages
17 Pages
6 Pages
4 Pages
4 Pages
5 Pages
17 Pages
2 Pages
10 Pages
10 Pages
6 Pages
11 Pages
9 Pages
8 Pages
7 Pages
4 Pages
4 Pages
4 Pages
7 Pages
198 Pages
8 Pages
9 Pages