Product tags: UV , Detector , 254nm (Disinfection) , Broadband-meter Gigahertz-Optik GmbH
Open the catalog to page 1The detector head UV-3725 is designed for the measurement of UV-C 254 nm radiation sources used in air disinfection. The UV-C radiation of air disinfection installations must be measured under the aspects of effectiv irradiance levels as well as under UV hazard aspects. Designed for wide dynamic The UV-3725 detector is designed for the highest possible UV-C 254 nm irradiance sensitivity to fulfill the Need in UV hazard applications. However the wide range linearity of the photodiodes coupled with the GigahertzOptik optometers’s wide dynamic signal range amplifiers enable the UV-3725 detector...
Open the catalog to page 2Calibration of irradiance responsivity in A/(W/m²) using a monochromatic 254 nm reference lamp. Calibration of the relative spectral responsivityfrom 250-550 nm Specification Spectral function Typical responsivity UVC @254nm radiometric: 7.4E.05 A/(W/cm²) UVC @254nm ICNIRP actinic: 1.5 A/(W/cm²) Measurement entrance Measurement entrance Connection cable coaxial cable 2 m Long, with BNC (-1), calibration data (-2) or ITT (-4) connector. Flexible metal tube Operation temperature Configurable with Produktname P-9710 Product Image Show product High-quality device for measurement of CW-, single pulse...
Open the catalog to page 3Product Image Show product Eight-channel optometer. Features: State-of-the-art 8 channel laboratory optometer with a signal amplifier and sample & hold ADC per channel for clocked recording of the measurement signals. RS232 and IEEE488 interface. Trigger input and output. X1-PCB Optometer module. Feature: The X1 optometer is available as a printed circuit board either with or without a housing and is suited for applications that do not require a keyboard or display. Four signal inputs enable connection with all measuring heads from GigahertzOptik. High-speed 1µs or 100ns rise time data logger...
Open the catalog to page 4Description Product Detector head with -1 connector, calibration certificate Detector head with -2 connector, calibration certificate Detector head with -4 connector, calibration certificate Re-calibration Re-calibration of integral irradiance responsivity in A/(W/m²) with calibration certificate Re-calibration of the relative spectral responsivity from 250-550 nm Gigahertz-Optik GmbH
Open the catalog to page 5Contact Person Gigahertz-Optik GmbH Tel. +49 (0)8193-93700-0 Fax +49 (0)8193-93700-50 [email protected] Gigahertz-Optik GmbH Powered by TCPDF (www.tcpdf.org)
Open the catalog to page 611 Pages
2 Pages
11 Pages
17 Pages
5 Pages
4 Pages
4 Pages
6 Pages
17 Pages
5 Pages
7 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
9 Pages
10 Pages
9 Pages
5 Pages
5 Pages
8 Pages
8 Pages
7 Pages
5 Pages
3 Pages
4 Pages
5 Pages
12 Pages
6 Pages
4 Pages
4 Pages
5 Pages
5 Pages
4 Pages
4 Pages
5 Pages
7 Pages
5 Pages
5 Pages
5 Pages
6 Pages
6 Pages
6 Pages
6 Pages
6 Pages
5 Pages
6 Pages
5 Pages
7 Pages
6 Pages
6 Pages
5 Pages
6 Pages
15 Pages
17 Pages
17 Pages
7 Pages
10 Pages
10 Pages
6 Pages
11 Pages
9 Pages
8 Pages
7 Pages
4 Pages
4 Pages
4 Pages
7 Pages
198 Pages
8 Pages
9 Pages