P-9801 - 1

Product tags: Optometer , Industrial Applications , Dosimeter , Flash measurement , Multi-Channel , Broadband-meter Gigahertz-Optik GmbH

Open the catalog to page 1
P-9801 - 2

The P-9801 series optometers are one of the most powerful light measurement instruments available for multiple light detector head applications. For use in those applications the P-9801 features: Industries most powerful and fastest multichannel light meter simultaneous measurement of all eight detector channels wide linear detector signal dynamic range short rise time with variable sampling rate fast multi-channel data-logging manual and remote control operation RS232 and IEEE488 interface powerful 16 bit microprocessor with large memory external trigger input with pre-trigger function...

Open the catalog to page 2
P-9801 - 3

P-9801-V01 is set-up with a gain dependent slew rate of 2 to 10 ms for universal light measurement purposes. P-9801-V02 amplifier offers a gain range independent rise time for the pulse energy measurement of short light flashes using a pulse stretching method. P-9801-V03 offers a fast rise time of 1 ms for high speed data logger applications with external trigger and pre-trigger function. Measurement Range Specifications with Light Detectors The measurement range of optometer combined with light detector is calculated by the measurement range specification of the optometer and the...

Open the catalog to page 3
P-9801 - 4

Offset correction Correction range transcending Detector interface 8 BNC sockets CW measurement mode: 8 channels (each 1 current input) Color measurement mode: 2 channels (each 4 current inputs) Trigger input CMOS level (0/5V) / BNC socket, internal pull-up 10 k to + 5 V Analog output Pulse trigger Key run / stop, Trigger In, Channel 1 – Channel 8, rising edge, trailing edge Pulse pre trigger time Parameter adjustment Remote control or front panel keys (menu), adjusted values permanently stored (EEPROM) Calibration information Stored in EEPROM CW: max. 20 detectors (each 80 entries),...

Open the catalog to page 4
P-9801 - 5

Measurement modes Menu item Display Mode Submenu item Absolute Relative Percent Relative Factor Relative Logarithmic Dose No Display Range Detector Ampere Manual Select Table Entry Select Detector Recalibration Offset Reference Main Mode CW Color Pulse Pulse Color RS232 IEEE488 Measurement Time Analog Out Dose Run Time Dose Maximum Display Illumination Display Digits Color Setup IEEE488 Address Function displays the measurement respective of any offset and calibration factors programmed displays the measurement as percentage of a reference value displays the measurement referred to a...

Open the catalog to page 5
P-9801 - 6

The device conforms with the requirements set out in the council directive on the approximation of the laws of the member states relating to electromagnetic compatibility (89/336/EEC). For the evaluation regarding electromagnetic compatibility, the following standards were applied: EN 61326-1 – Class B Desktop Power Supply Configurable with Produktname VL-3701 Product Image Show product Detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate Detector...

Open the catalog to page 6
P-9801 - 7

Product Image Show product Very high sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 28nA/lx, no diffuser, for the usage with optometers and amplifiers, calibration Module detector head for the measurement of photopic illuminance in Lux [lx]. Very high sensitive illuminance detector head for spotlamps Features: UMPA adapter for usage with integrating spheres, for the usage with optometers and amplifiers, calibration certificate Features: Large diameter lens zur Erhöhung der Empfindlichkeit, for the usage with optometers and amplifiers,...

Open the catalog to page 7
P-9801 - 8

Product Image Show product Integrating sphere detector for luminous flux (lm) of 2π spot sources. Features: 50mm dia, BaSO4 coating, 12.5mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π spot sources. Features: 100mm dia, BaSO4 coating, 25.4mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 150mm dia, BaSO4 coating, 38.1mm dia port, for the usage with optometers and signal...

Open the catalog to page 8
P-9801 - 9

Product Image Show product PD-9310A measurement head with GB-GD-360 photogoniometer for measurement of the luminous intensity distribution of 2π spot lamps and LEDs. Goniometer bench with adjustable measurement distance of up to 2000 mm. PD-9310A photometric detector corresponding to the DIN 5032 quality class A. Calibration certificate conformng to the ISO 17025 specifications. For use with all optometers and signal amplifiers from Gigahertz-Optik GmbH. Detector head for the measurement of irradiance in W/m². Features: spectral responsivity from 400-500nm (BLUE), cosine field-of-view, for...

Open the catalog to page 9
P-9801 - 10

Product Image Show product Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 200/250-280nm (UV-C), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 320-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 280-320nm...

Open the catalog to page 10
P-9801 - 11

Product Image Show product Detector head for the measurement of high irradiance of UV-C 254nm radiation in W/m². Features: pre-aging for long time stability, cosine field-of-view, metal shielded cable, for the usage with optometers and amplifiers, calibration certificate. Detector for the measurement of UV-C 254 nm irradiance in air disinfection applications Features: wide dynamic range for UV hazard and effective irradiance, wide angle cosine F.O.V. for straylight measurements, for the usage with optometers, calibration certificate. Detector head for high intensity irradiation as in UV or...

Open the catalog to page 11

All Gigahertz Optik GmbH catalogs and technical brochures

  1. ISD-5-Si

    5 Pages

  2. XD-9510

    4 Pages

  3. XD-9509

    4 Pages

  4. X1-UV-3727

    6 Pages

  5. X1

    17 Pages

  6. BTS256-PAR

    8 Pages

  7. ISS-30-VA

    5 Pages

  8. ISS-8P-VAHP

    5 Pages

  9. PLL-1701

    5 Pages

  10. TPI21-TH

    5 Pages

  11. UPB-150-ART

    9 Pages

  12. UPB-150-ARTA

    10 Pages

  13. UPG-150-ART

    9 Pages

  14. VL-3704

    5 Pages

  15. BN-9101

    5 Pages

  16. BTS2048-UV-S

    8 Pages

  17. CSS-45

    7 Pages

  18. ISS-17-VA

    5 Pages

  19. TFCT25

    4 Pages

  20. P-9802

    12 Pages

  21. LDM-9811

    6 Pages

  22. PS-3702

    4 Pages

  23. TP-4501

    4 Pages

  24. UV-3709

    5 Pages

  25. XD-45-ERYC

    5 Pages

  26. XD-45-HUV

    4 Pages

  27. ISD-0.8-SiLP

    4 Pages

  28. ISD-30-Si

    5 Pages

  29. ISD-3P-Si

    7 Pages

  30. ISD-5P-SiUV

    5 Pages

  31. XD-9506

    5 Pages

  32. RCH-005

    6 Pages

  33. RCH-014

    6 Pages

  34. RCH-115

    6 Pages

  35. RCH-116

    6 Pages

  36. RW-3708

    6 Pages

  37. UV-3711-308

    5 Pages

  38. UV-3725

    6 Pages

  39. ISD-15P-VL

    6 Pages

  40. ISD-5-VL

    5 Pages

  41. LDM-9901

    7 Pages

  42. PD-9310A

    6 Pages

  43. VL-3701

    6 Pages

  44. CT-4501

    5 Pages

  45. P-9202-6

    6 Pages

  46. P-2000

    17 Pages

  47. P-9710

    17 Pages

  48. X1-4

    7 Pages

  49. X1-PCBC

    10 Pages

  50. X1-RM

    10 Pages

  51. X1-3

    6 Pages

  52. BTS2048-VL

    11 Pages

  53. BTS256-EF

    9 Pages

  54. BTS256-E

    8 Pages

  55. MSC15

    7 Pages

  56. LS-OK30

    4 Pages

  57. LP-9910

    4 Pages

  58. LH-xxF

    4 Pages

  59. ISD-10-VL

    7 Pages

Archived catalogs

  1. BTS256-PAR

    9 Pages