video corpo

P-9801

P-9801
1 / 15 PagesView full catalog

P-9801

Product catalog summary
Overview: The P-9801 series optometers are sophisticated instruments for light measurement, designed to handle multiple detector heads. They feature simultaneous measurement across eight channels, a broad dynamic range, rapid data logging, and options for both manual and remote control.

Key Features: Equipped with a 16-bit microprocessor, the P-9801 supports RS232 and IEEE488 interfaces. It offers true eight-channel operation with photocurrent-to-voltage amplifiers and 12-bit ADCs for simultaneous signal sampling. The dynamic current measurement range spans from 0.1 pA to 2 mA, with eight gain ranges calibrated to 0.2% precision. Integration time is adjustable from 1 ms to 999 s.

Versions: There are three versions tailored for specific applications: P-9801-V01 for general use, P-9801-V02 for pulse energy measurement, and P-9801-V03 for high-speed data logging.

Measurement Range: The range is influenced by the optometer's specifications and the detector's responsivity, including calculations for offset signal, and minimum and maximum measurable irradiation.

Calibration and Operation: The device supports calibration across eight gain levels and can store settings for multiple detector heads. It offers various measurement modes such as absolute, relative, dose, and pulse measurements, with remote control via RS232 and IEEE488.

Physical and Environmental Specifications: The optometer is encased in metal for electromagnetic shielding, measuring 280 mm x 250 mm x 70 mm. It operates in temperatures from 5 to 40°C and humidity levels below 80% without condensation.

Accessories and Compatibility: Compatible with various detector heads for different measurement needs, including photopic illuminance, laser radiant power, and UV radiation. It also includes software development kits and application software for enhanced functionality.
See more

Catalog excerpts

P-9801-1

Product tags: Dosimeter , Multi-Channel , Gigahertz Optik GmbH

 Open the catalog to page 1
P-9801-2

The P-9801 series optometers are one of the most powerful light measurement instruments available for multiple light detector head applications. For use in those applications the P-9801 features: Industries most powerful and fastest multichannel light meter • simultaneous measurement of all eight detector channels • wide linear detector signal dynamic range • short rise time with variable sampling rate • fast multi-channel data-logging • manual and remote control operation • powerful 16 bit microprocessor with large memory • external trigger input with pre-trigger function True eight-channel...

 Open the catalog to page 2
P-9801-3

Three different versions for universal use in high speed applications P-9801-V01 is set-up with a gain dependent slew rate of 2 ms to 10 ms for universal light measurement purposes. P-9801-V02 amplifier offers a gain range independent rise time for the pulse energy measurement of short light flashes using a pulse stretching method. P-9801-V03 offers a fast rise time of 1 ms for high speed data logger applications with external trigger and pre-trigger function. Measurement Range Specifications with Light Detectors The measurement range of optometer combined with light detector is calculated by...

 Open the catalog to page 3
P-9801-4

Calibrate and adjust the current sensitivity in all eight gain levels. Memory for the calibration data of several measuring heads for the measurement in the absolute unit of the selected measuring head. Product Power Supply Detector interface 8 BNC sockets Information: By color measurements four channels are needed for one detector, this is why two color channels are possible. CMOS level (0/5V) / BNC socket, internal pull-up 10 k to + 5 V Analog output Amperes, optical units corresponding to calibration data, factor, percent, log (depends on the measurement quantity) Measurement range Pulse trigger...

 Open the catalog to page 4
P-9801-5

Plug Types To connect the P-9801 to the RS232 interface of a PC a 1:1 cable has to be used (one side male connector, the other side female connector, no null modem cable!) Measurement modes Menu item Submenu item Display Mode Absolute Relative Percent Relative Factor Detector Ampere Select Table Entry Select Detector Recalibration Pulse Color Setup Measurement Time Dose Maximum Display Illumination Display Digits Color Setup displays the measurement respective of any offset and calibration factors programmed displays the measurement as percentage of a reference value displays the measurement...

 Open the catalog to page 5
P-9801-6

Front panel control 16 keys, menu system Temperature range Regular recalibration of the current calibration is recommended. Especially when very small measurement currents have to be measured. In the case of very high humidity, fault currents of the radiometer are possible at low measuring currents and should be taken into account. Accessories Power Supply Configurable with Product Name Detector head for the measurement of photopic illuminance in Lux [lx] Detector head for the measurement of photopic illuminance in Lux [lx]. Class B, f1' ≤ 6 % Detector head for the measurement of photopic illuminance...

 Open the catalog to page 6
P-9801-7

Product Name Very high sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 28nA/lx, no diffuser, for the usage with optometers and amplifiers, calibration Detector head to measure Laser radiant power in W and Laser irradiance in W/m² Detector head to measure the photopic illuminance in lx and the luminance in cd/m² High sensitive detector head to measure the photopic luminance in cd/m². Features: front lense for 1°, 2°, 5° or 10° viewing angle, for the usage with Optometers and amplifiers, calibration certificate RGB detector head for photopic...

 Open the catalog to page 7
P-9801-8

Product Name Application software for P9801 variants. Module detector head for the measurement of photopic illuminance in Lux [lx]. Features: UMPA adapter for usage with integrating spheres, for the usage with optometers and amplifiers, calibration certificate Integrating sphere detector for luminous flux (lm) of 2π spot sources Integrating sphere detector for luminous flux (lm) of 2π spot sources Integrating sphere detector for luminous flux (lm) of 2π sources Photometric, temperature stabilized detector with DP-11 mount Detector head for the measurement of irradiance in W/m² in the spectral...

 Open the catalog to page 8
P-9801-9

Product Name Detector head for the measurement of irradiance in W/m² in the spectral range 400 nm - 1000 nm (VISNIR). Detector head for the measurement of irradiance in W/m² in the spectral range 1000 nm - 1700 nm (NIR). Detector head for the measurement of irradiance of UV radiation in W/m² from 315 nm - 400 nm (UV-A). Detector head for the measurement of irradiance of UV radiation in W/m² from 280 nm - 315 nm (UV-B). Detector head for the measurement of irradiance of UV radiation in W/m² from 250 nm - 280 nm (UV-C). Detector head for the measurement of irradiance of UV radiation in W/m² in...

 Open the catalog to page 9
P-9801-10

Product Name Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 350-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of high irradiance of UV-C 254 nm radiation in W/m² Integrating sphere detector for radiant power in W of 2π sources ISD-3P-Si Laser Power Detector Integrating sphere detector for Laser power in W Detector head to measure irradiance W/m² in Bilirubin phototherapy. Features: Bilirubin actinic responsivity, cosine fieldof-view, for...

 Open the catalog to page 10
P-9801-11

Product Name Detector head with rigid fiber for high intensity UV and BLUE LED sources. Detector head for high intensity irradiation in UVA and blue light curing processes with rigid fiber Photometric detector head with M30x1 mount Scotopic detector head with M30x1 mount Universal detector head for LASER power, illuminance and 400-1100 nm iiradiance. Features: Si-photodiode with 1 cm², exchange able filters and cosine diffuor, for the usage with optometers and signal amplifiers ISD-5P-Si Laser Power Detector Integrating sphere detector for Laser power in W ISD-10-Si Laser Power Detector Integrating...

 Open the catalog to page 11

All Gigahertz Optik GmbH catalogs and technical brochures

  1. ISD-5-VL

    6  Pages

  2. LDM-1901

    7  Pages

  3. CSS-45-UV

    6  Pages

  4. BTS256-UV

    9  Pages

  5. BTS2048-UV-S-WP

    11  Pages

  6. TFUV10

    7  Pages

  7. BTS2048-NIR

    7  Pages

  8. BTS2048-UV-2

    9  Pages

  9. P-21

    14  Pages

  10. X1-UV-3725

    5  Pages

  11. X1

    17  Pages

  12. VL-3701

    9  Pages

Archived catalogs

  1. XD-45-ERYC

    5  Pages

  2. UV-3709

    5  Pages

  3. TP-4501

    4  Pages

  4. PS-3702

    4  Pages

  5. LDM-9811

    6  Pages

  6. P-9802

    12  Pages

  7. TFCT25

    4  Pages

  8. ISS-17-VA

    5  Pages

  9. ISD-3P-Si

    7  Pages

  10. RW-3708

    6  Pages

  11. RCH-116

    6  Pages

  12. RCH-115

    6  Pages

  13. RCH-014

    6  Pages

  14. XD-9506

    5  Pages

  15. RCH-005

    6  Pages

  16. ISD-5P-SiUV

    5  Pages

  17. ISD-30-Si

    5  Pages

  18. ISD-0.8-SiLP

    4  Pages

  19. XD-45-HUV

    4  Pages

  20. UV-3725

    6  Pages

  21. P-9710

    17  Pages

  22. P-2000

    17  Pages

  23. P-9801

    15  Pages

  24. P-9202-6

    6  Pages

  25. CT-4501

    5  Pages

  26. VL-3701

    6  Pages

  27. PD-9310A

    6  Pages

  28. LDM-9901

    7  Pages

  29. ISD-5-VL

    5  Pages

  30. ISD-15P-VL

    6  Pages

  31. UV-3711-308

    5  Pages

  32. X1-4

    7  Pages

  33. CSS-45

    7  Pages

  34. BTS2048-UV-S

    8  Pages

  35. BN-9101

    5  Pages

  36. VL-3704

    5  Pages

  37. UPG-150-ART

    9  Pages

  38. UPB-150-ARTA

    10  Pages

  39. UPB-150-ART

    9  Pages

  40. TPI21-TH

    5  Pages

  41. PLL-1701

    5  Pages

  42. ISS-8P-VAHP

    5  Pages

  43. ISS-30-VA

    5  Pages

  44. BN-LHSF-2P-20

    5  Pages

  45. X1

    17  Pages

  46. X1-UV-3727

    6  Pages

  47. XD-9509

    4  Pages

  48. XD-9510

    4  Pages

  49. ISD-5-Si

    5  Pages

  50. Image Brochure

    17  Pages

  51. X1-PCBC

    10  Pages

  52. X1-RM

    10  Pages

  53. X1-3

    6  Pages

  54. BTS2048-VL

    11  Pages

  55. BTS256-EF

    9  Pages

  56. BTS256-E

    8  Pages

  57. MSC15

    7  Pages

  58. LS-OK30

    4  Pages

  59. LP-9910

    4  Pages

  60. LH-xxF

    4  Pages

  61. ISD-10-VL

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.