video corpo

P-9710

P-9710
1 / 17 PagesView full catalog

P-9710

Product catalog summary
Overview
The P-9710 series by Gigahertz-Optik GmbH consists of multi-functional light meters designed for high-quality photometric measurements. These devices are suitable for mobile use, offering a wide dynamic range and low noise-equivalent current signal.
Specifications
  • P-9710-1: Equipped with a trans-impedance amplifier with eight gain levels, ideal for continuous wave (CW) measurements.
  • P-9710-2: Similar to P-9710-1 but includes a 20ms time constant for measuring pulse energy of single pulses.
  • P-9710-4: Features a trigger input for synchronized pulse energy measurement.
Measurement Capabilities
The P-9710 series supports various measurement modes, including CW, peak, pulse energy, and dose measurements. It can be paired with different detector heads to measure photometric and radiometric values.
Key Features
  • Variable integration times for noise reduction and multiple measurement functions.
  • Remote operation via RS232 interface.
  • Automatic application of calibration data upon detector head attachment.
  • Data logging capability for up to 12,288 measurement values.
Measurement Ranges
The optometers offer a wide range of measurement capabilities, determined by the detector head's responsivity and the optometer's current measurement range. The noise equivalent measurement signal and maximum measurable irradiance are calculated based on these parameters.
Accessories
The P-9710 series is compatible with various detector heads and integrating sphere detectors, each designed for specific measurement tasks such as photopic illuminance and luminous flux.
Compliance and Warranty
The devices conform to electromagnetic compatibility standards and are RoHS compatible. They come with a 12-month warranty.
Product Overview
The document also details other optical measurement products by Gigahertz-Optik GmbH, including the UV-3725RW-37 with SRT-M37-L Detector heads, ISS-5P Integrating Sphere Source, and ISS-5P-SR-FS Integrating Sphere Source for fluorescence spectroscopy.
Specifications and Features
  • UV-3725RW-37 with SRT-M37-L Detector Heads: Measures irradiance in W/m² and radiance in W/(m²*sr), with front lenses offering 1°, 2°, or 5° viewing angles, suitable for use with optometers and amplifiers, and includes a calibration certificate.
  • ISS-5P Integrating Sphere Source: Compact with a 20mm diameter light port, in-line baffle, synthetic ODM98 coating, and halogen lamp. Calibrated for spectral radiance from 380-1100nm, with a calibration certificate.
  • ISS-5P-SR-FS Integrating Sphere Source: Designed as a spectral radiance standard in fluorescence spectroscopy, featuring low spectral radiance, compact size, synthetic ODM98 coating, and calibration from 380-1700nm.
Software and Accessories
  • S-SDK-P9710: Software Development Kit for P9710 variants.
  • Accessories: Includes RS232 adapter cable, relay card with RS232 interface, connection plugs kit, adapter cable for detectors with BNC plugs, and hard-top casing for the measurement device and accessories.
Purchasing Information
Details on purchasing options, including model numbers and descriptions, are provided for measurement devices and accessories.
Contact Information
Contact details for Gigahertz-Optik GmbH are provided for further inquiries.
See more

Catalog excerpts

P-9710-1

Product tags: Optometer , Industrial Applications , Dosimeter , Flash measurement , Blondel-Rey , Broadband-meter Gigahertz-Optik GmbH

 Open the catalog to page 1
P-9710-2

Description P-9710-1 – Multi-functional light meter for highquality photometric measurements The P-9710-1 optometer is a high-quality device designed by GigahertzOptik for mobile use. Its signal amplifier provides a wide dynamic range for the detectors’ signal currents ranging up to 2 mA. The noise-equivalent current signal is as low as 0.1 pA. The device has eight gain ranges that can be manually or automatically selected for adjustment to match the signal levels. Variable integration time One of the characteristic properties of the P-9710-1 optometer is the short integration time of the input...

 Open the catalog to page 2
P-9710-3

Light measurements and light analysis The P-9710-1 optometer has eighteen different measurement modes that can easily be selected using a user-friendly menu hence enabling its multifunctional application. P-9710-2 – Optometer for dose measurement of short pulses using the pulse stretching method Unlike the P-9710-1, the P-9710-2 optometer has a 20 ms standard time constant in all eight gain ranges. Thus light pulses shorter than 1 ns are stretched to 20 ms. The pulse energy of the stretched pulse can then be measured precisely with the 100 µs sample rate of the optometer. P-9710-4 – multi-functional...

 Open the catalog to page 3
P-9710-4

Measurement ranges range (A / V) gain error ± offset error (at 20 °C) gain (A / V) analogue output Measurement range detector head The optometer P-9710-1, P-9710-2 and P-9710-4 can be combined with all single-channel detector heads from Gigahertz-Optik. The typical responsivities of the detectors in A/W, A/lx, etc. are specified in the corresponding specifications. These specifications can be used to calculate the measurement ranges of the measurement heads in connection with the P-9710-1, P-9710-2 and P-9710-4 optometer as described below: The measurement range of a light meter comprising of...

 Open the catalog to page 4
P-9710-5

Measurement modes The product has eighteen different measurement modes that can easily be selected using a userfriendly menu hence enabling its multifunctional application. CW CW Maximum CW Minimum Peak Maximum Peak Minimum Peak to Peak I Pulse energy Relative (%) Relative (Log) Relative (Fact.) Hold CW Level Check Continuous measurements in the measurement interval of the selected integration time. Display of the current CW measurement value and the maximum CW value attained. Display of the current CW measurement value and the minimum CW value attained. Display of the current CW average value...

 Open the catalog to page 5
P-9710-6

Offset correction Exceeding correction range Measurement parameter setup Via RS232 or using control panel on the front side. Settings are permanently saved (EEPROM). Ten different settings can be saved Data logger Max. 12288 entries, permanently saved in flash memory Miscellaneous Dimensions / Weight RS232 (9600 baud, 8 data bits, 1 stop bit, no parity) Plug: TRIAD01 (Tyco) Voltage supply Rechargeable battery, battery capacity: 6 V, 0.5 Ah Operation time: 5 hours with display backlight switched on, 12 hours with display backlight switched off 5.5 mm / 2.5 mm / 9.5 mm socket for plug-in power...

 Open the catalog to page 6
P-9710-7

Product Image Show product Detector head for the measurement of scotopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.2nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate High sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration certificate High sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers,...

 Open the catalog to page 7
P-9710-8

Product Image Show product Integrating sphere detector for luminous flux (lm) of 2π spot sources. Features: 100mm dia, BaSO4 coating, 25.4mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 150mm dia, BaSO4 coating, 38.1mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 150mm dia, synthetic coating, 38.1mm dia port, for the usage with optometers and signal amplifiers,...

 Open the catalog to page 8
P-9710-9

Product Image Show product Integrating sphere detector for luminous flux (lm) of 2π and 4π sources. Features: 500mm dia, BaSO4 coating, sphere to open, auxiliary lamp, for the usage with optometers and signal amplifiers, Calibration certificate VL-1101 module light detectors with photometric V(λ) responsivity Photometric detector head with DP-11 mount. Photometric detector head with M30x1 mount. Features: modular detector for use with integrating spheres, front lenses etc. For use with optometers and signal amplifiers Features: modular detector for use MD-37, SRT and other accessories. For use...

 Open the catalog to page 9
P-9710-10

Product Image Show product Detector head for the measurement of irradiance in W/m². Features: spectral responsivity from 400-800nm (VIS), cosine fieldof-view, for the usage with optometers and amplifiers, calibration certificate Detector head for the measurement of irradiance in W/m². Features: spectral responsivity from 800-1000nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate Detector head for the measurement of irradiance in W/m². Features: spectral responsivity from 400-1000nm (VISNIR), cosine field-of-view, for the usage with optometers...

 Open the catalog to page 10
P-9710-11

Product Image Show product Integrating sphere detector with short rise time for Laser power in W. Features: 8mm dia, ODM98 coating, 400-1100nm responsivity, optional SMA Adapter, for the usage with fast optometers and signal amplifiers, Calibration certificate Integrating sphere detector for Laser power in W. Features: 16mm dia, 3mm dia port, BaSO4 coating, 400-1100nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for Laser power in W. Features: 30mm dia, 5mm dia port, synthetic ODM98 coating, 400-1100nm responsivity, for...

 Open the catalog to page 11

All Gigahertz Optik GmbH catalogs and technical brochures

  1. Image Brochure

    17  Pages

  2. ISD-5-Si

    5  Pages

  3. XD-9510

    4  Pages

  4. XD-9509

    4  Pages

  5. X1-UV-3727

    6  Pages

  6. X1

    17  Pages

  7. BN-LHSF-2P-20

    5  Pages

  8. ISS-30-VA

    5  Pages

  9. ISS-8P-VAHP

    5  Pages

  10. PLL-1701

    5  Pages

  11. TPI21-TH

    5  Pages

  12. UPB-150-ART

    9  Pages

  13. UPB-150-ARTA

    10  Pages

  14. UPG-150-ART

    9  Pages

  15. VL-3704

    5  Pages

  16. BN-9101

    5  Pages

  17. BTS2048-UV-S

    8  Pages

  18. CSS-45

    7  Pages

  19. ISS-17-VA

    5  Pages

  20. TFCT25

    4  Pages

  21. P-9802

    12  Pages

  22. LDM-9811

    6  Pages

  23. PS-3702

    4  Pages

  24. TP-4501

    4  Pages

  25. UV-3709

    5  Pages

  26. XD-45-ERYC

    5  Pages

  27. XD-45-HUV

    4  Pages

  28. ISD-0.8-SiLP

    4  Pages

  29. ISD-30-Si

    5  Pages

  30. ISD-3P-Si

    7  Pages

  31. ISD-5P-SiUV

    5  Pages

  32. XD-9506

    5  Pages

  33. RCH-005

    6  Pages

  34. RCH-014

    6  Pages

  35. RCH-115

    6  Pages

  36. RCH-116

    6  Pages

  37. RW-3708

    6  Pages

  38. UV-3711-308

    5  Pages

  39. UV-3725

    6  Pages

  40. ISD-15P-VL

    6  Pages

  41. ISD-5-VL

    5  Pages

  42. LDM-9901

    7  Pages

  43. PD-9310A

    6  Pages

  44. VL-3701

    6  Pages

  45. CT-4501

    5  Pages

  46. P-9202-6

    6  Pages

  47. P-9801

    15  Pages

  48. P-2000

    17  Pages

  49. X1-4

    7  Pages

  50. X1-PCBC

    10  Pages

  51. X1-RM

    10  Pages

  52. X1-3

    6  Pages

  53. BTS2048-VL

    11  Pages

  54. BTS256-EF

    9  Pages

  55. BTS256-E

    8  Pages

  56. MSC15

    7  Pages

  57. LS-OK30

    4  Pages

  58. LP-9910

    4  Pages

  59. LH-xxF

    4  Pages

  60. ISD-10-VL

    7  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.