P-2000
17Pages

{{requestButtons}}

Catalog excerpts

P-2000 - 1

Product tags: Optometer , Dosimeter , Flash measurement , Blondel-Rey , Multi-Channel , Broadband-meter Gigahertz-Optik GmbH

Open the catalog to page 1
P-2000 - 2

Available in two versions the P-2000 optometers are highly efficient dualchannel instruments designed for multipurpose use in most photometric and radiometric applications including pulsed light measurement. Its compact size, four line blue back-lit display and unlimited detector interchange, functions and features characterize the P-2000 as all purpose laboratory grade instrument. Safe Detector Head exchange P-2000 with Optional Integrating Sphere Detector A unique feature of the P-2000 is its detector head calibration data connector which stores all data pertaining to a light detector...

Open the catalog to page 2
P-2000 - 3

calculated by the measurement range specification of the optometer and the responsivity of the detector head as follows: Offset signal = Maximum Resolution = meter current offset signal / detector sensitivity Sample: 0.1 pA (0.1E-12 A) / 3 nA/(mW/cm²) (irradiance detector) = 0.33 nW/cm² Minimum measureable irradiation = offset signal * signal to noise ratio factor Sample: 0.33 nW/cm² * 50 = 17 nW/cm² Adapter cable to connect detectors with BNC connectors (-1 type) to the 9PIN SUBD socket Maximum measureable irradiation = max. signal current detector / detector sensitivity Sample: 1 mA...

Open the catalog to page 3
P-2000 - 4

Remote interface RS232: 9600 Baud, 8 Data Bit, 1 Stop Bit, No Parity, Connector DSUB 9pins, female IEEE488: AH1, SH1, L4, T4 Analogue output Output voltage corresponding to detector input current (Ri = 10k) connector: BNC Parameter adjustment Remote control or front panel keys (menu), adjusted values permanently stored (EEPROM) Calibration information Stored in the detector connector (EEPROM) Manual calibration factor (keys) Max. 250 calibration table entries + interpolation between the entries Logger memory Max. 5734 entries for each channel, permanently stored in flash memory Range...

Open the catalog to page 4
P-2000 - 5

Measurement modes Menu Item 1. Mode 4. Offset 5. Reference 6. Setup Gigahertz-Optik GmbH Function displays the measurement respective of any offset and calibration factors programmed CW displays the highest detected Maximum reading CW displays the lowest detected Minimum reading Peak shows the maximum detected Maximum peak level Peak displays the minimum detected Minimum peak level Peak to displays the difference between Peak the detected peak maximum and peak minimum level I-Effective enables the measurement of pulsed light signals with evaluation of the effective intensity according to...

Open the catalog to page 5
P-2000 - 6

Pulse Meas.-Time IF Time Constant Pulse Offset CW Level Check Dose Run Time Dose Maximum Dose Relay Control Logger Time Display Digits Default Init Channel IEEE488 Address Synchronisa tion 7. Info Logger data CW Level Min. CW Level Max. Default Init Synchroniza tion Substitution Code Number Configuratio n Battery Status Logger data needs to be set for the measuring modes I-Effective and Pulse Energy. It defines the time for collecting readings and shall be a little longer than the expected pulse width. sets the time constant C in the Schmidt-Clausen formula determines the method of offset...

Open the catalog to page 6
P-2000 - 7

The device conforms with the requirements set out in the council directive on the approximation of the laws of the member states relating to electromagnetic compatibility (89/336/EEC). For the evaluation regarding electromagnetic compatibility, the following standards were applied: EN 61326-1 - Class B Plug In Power Supply Configurable with Produktname VL-3701 Product Image Show product Detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate Detector...

Open the catalog to page 7
P-2000 - 8

Product Image Show product Very high sensitive detector head for the measurement of photopic illuminance in Lux [lx]. Features: f1 ≤ 3 %, 28nA/lx, no diffuser, for the usage with optometers and amplifiers, calibration Very high sensitive illuminance detector head for spotlamps Features: Large diameter lens zur Erhöhung der Empfindlichkeit, for the usage with optometers and amplifiers, calibration Detector head to measure the photopic spot luminance in cd/m². Features: selectable 20', 1° and 6° viewing angles, view finder, focus able achromatic lens, for the usage with Optometers and...

Open the catalog to page 8
P-2000 - 9

Product Image Show product Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 150mm dia, BaSO4 coating, 38.1mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 150mm dia, synthetic coating, 38.1mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate Integrating sphere detector for luminous flux (lm) of 2π sources. Features: 300mm dia, BaSO4 coating, 101,6mm dia port, for the usage with optometers and signal amplifiers,...

Open the catalog to page 9
P-2000 - 10

Product Image Show product Universal detector head for LASER power, illuminance and 400-1100 nm iiradiance. Features: Si-photodiode with 1 cm², exchange able filters and cosine diffuor, for the usage with optometers and signal amplifiers PD-9310A measurement head with GB-GD-360 photogoniometer for measurement of the luminous intensity distribution of 2π spot lamps and LEDs. Goniometer bench with adjustable measurement distance of up to 2000 mm. PD-9310A photometric detector corresponding to the DIN 5032 quality class A. Calibration certificate conformng to the ISO 17025 specifications. For...

Open the catalog to page 10
P-2000 - 11

Product Image Show product Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 280-315nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 200/250-280nm (UV-C), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate. Detector head for the measurement of irradiance of UV radiation in W/m². Features: spectral responsivity from 320-400nm...

Open the catalog to page 11

All Gigahertz Optik GmbH catalogs and technical brochures

  1. ISD-5-Si

    5 Pages

  2. XD-9510

    4 Pages

  3. XD-9509

    4 Pages

  4. X1-UV-3727

    6 Pages

  5. X1

    17 Pages

  6. BTS256-PAR

    8 Pages

  7. ISS-30-VA

    5 Pages

  8. ISS-8P-VAHP

    5 Pages

  9. PLL-1701

    5 Pages

  10. TPI21-TH

    5 Pages

  11. UPB-150-ART

    9 Pages

  12. UPB-150-ARTA

    10 Pages

  13. UPG-150-ART

    9 Pages

  14. VL-3704

    5 Pages

  15. BN-9101

    5 Pages

  16. BTS2048-UV-S

    8 Pages

  17. CSS-45

    7 Pages

  18. ISS-17-VA

    5 Pages

  19. TFCT25

    4 Pages

  20. P-9802

    12 Pages

  21. LDM-9811

    6 Pages

  22. PS-3702

    4 Pages

  23. TP-4501

    4 Pages

  24. UV-3709

    5 Pages

  25. XD-45-ERYC

    5 Pages

  26. XD-45-HUV

    4 Pages

  27. ISD-0.8-SiLP

    4 Pages

  28. ISD-30-Si

    5 Pages

  29. ISD-3P-Si

    7 Pages

  30. ISD-5P-SiUV

    5 Pages

  31. XD-9506

    5 Pages

  32. RCH-005

    6 Pages

  33. RCH-014

    6 Pages

  34. RCH-115

    6 Pages

  35. RCH-116

    6 Pages

  36. RW-3708

    6 Pages

  37. UV-3711-308

    5 Pages

  38. UV-3725

    6 Pages

  39. ISD-15P-VL

    6 Pages

  40. ISD-5-VL

    5 Pages

  41. LDM-9901

    7 Pages

  42. PD-9310A

    6 Pages

  43. VL-3701

    6 Pages

  44. CT-4501

    5 Pages

  45. P-9202-6

    6 Pages

  46. P-9801

    15 Pages

  47. P-9710

    17 Pages

  48. X1-4

    7 Pages

  49. X1-PCBC

    10 Pages

  50. X1-RM

    10 Pages

  51. X1-3

    6 Pages

  52. BTS2048-VL

    11 Pages

  53. BTS256-EF

    9 Pages

  54. BTS256-E

    8 Pages

  55. MSC15

    7 Pages

  56. LS-OK30

    4 Pages

  57. LP-9910

    4 Pages

  58. LH-xxF

    4 Pages

  59. ISD-10-VL

    7 Pages

Archived catalogs

  1. BTS256-PAR

    9 Pages