Technical Datasheet Scalar Network Analyzer Model 8003 - 10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 dB wide dynamic range with the accuracy and linearity of a power meter in a signal instrument.
Open the catalog to page 18003 Precision Scalar Network Analyzer Wide Dynamic Range Absolute Power Measurements The Model 8003 Precision Scalar Network Analyzer can make accurate, single sensor power measurements over a frequency range of 10 MHz to 40 GHz with a dynamic range of –70 to +20 dBm. The same built-in calibrator that linearizes the sensor provides a 1 mW signal accurate to within ±0.7%, stable over temperature and time, and traceable to NIST. Each Giga tronics power sensor contains an EEPROM programmed with the frequency calibration factors measured at the factory, or in your Cal Lab. When you key in the...
Open the catalog to page 28003 Technical Specifications System Specifications Frequency Range: 10 MHz to 40 GHz in coax using the Gigatronics 80300 Series power sensors and 80500 Series bridges. Readout Modes: dBm: single channel power measurement. dB: relative power measurement Lin: nW, μW, mW and Watts: signal channel measurement. %: dual channel measurement. % Rel: dual channel measurement relative to a reference. Power Range: +30 to -70 dBm, see power sensor specifications. Channel Offset: -90 dB to +90 dB in .01 dB increments. System Dynamic Range: CW Measurements: 90 dB Peak Measurements: 40 dB Swept...
Open the catalog to page 38003 Precision Scalar Network Analyzer Cursor: The cursor can be positioned with the tuning knob or via the numeric keypad. The frequency and amplitude test data at the cursor on all active channels is digitally displayed. Cursor Delta: Displays differences in dB and frequency between the reference cursor and the main cursor. Cursor Min/Max: Automatically moves the cursor to the minimum or maximum value of test data. Cursor "x" dB: Automatically moves the cursor to the point on the trace equal to the value of "x" in dB or dBm. Cursor "x" Bandwidth: Automatically displays cursors right and...
Open the catalog to page 4Reflection Measurements: When measuring devices with high return loss (>10 dB), reflection accuracy is typically dominated by the effective system directivity (Fig. 2), instrument linearity errors, and noise uncertainty. With low return loss devices (<10 dB), reflection accuracy is typically dominated by source match (Fig. 3). Calibration with an open and short effectively removes uncertainties due to frequency response of the source, sensors, and signal splitting device. Figure 2 Reflection Uncertainly versus Directivity Reflection Accuracy = Instrument Accuracy + Reflection Bridge...
Open the catalog to page 58003 Precision Scalar Network Analyzer Absolute Power Measurement Accuracy: The absolute power measurement accuracy is determined by a number of factors including calibrator accuracy, noise, sensor calibration factor error, and the mismatch uncertainty between sensor and device under test. Calibrator: Provides a 50 MHz calibration signal at 51 very accurately controlled levels from +20 to -30 dBm to dynamically linearize the sensors. Calibrator Frequency: 50 MHz nominal Temperature Coefficient of Linearity: < 0.3%/°C temperature change after calibration Zeroing Accuracy, (CW Mode, Averaging...
Open the catalog to page 68003 Technical Specifications Rear Panel Inputs and Outputs Sweep In (Sweep Voltage Requirements): (BNC connector). 0 to +10 V nominal. Blanking Input: (BNC connector) Used to blank the sweep oscillator (swept signal generator) band switching points on the 8003 display. Voltage level: Blanked > 2 V; Un-blanked < 0.8 V (typical) Input 1: (BNC connector) TTL levels, used with some sweepers (swept signal generator) to provide synchronization. Directional Bridges The 80500 Series of Directional Bridges are designed specifically for use with the 8003 to measure the return loss of a test device....
Open the catalog to page 78003 Technical Specifications Giga-tronics CW Power Sensor Selection Guide Frequency Range / Power Rangee Maximum Power Power Linearity 1 (Frequency > 8 GHz) Low VSWR CW Power Sensors 80310A Giga-tronics True RMS Power Sensors Selection Guide (fm > 1.5 MHz) Frequency Range / Power Range Maximum Power Power Linearity 1 (Frequency > 8 GHz) Includes System Linearity. The K connector is electrically and mechanically compatible with the APC-3.5 and SMA connectors. Note: Use a Type N(m) to SMA(f) adapter (part no. 29835) for calibration of power sensors with Type K(m) connectors. 1
Open the catalog to page 8Sensor Calibration Factor Uncertainties Frequency (GHz) Root Sum of Squares (RSS) Uncertainties (%)3 3 Square root of sum of the individual uncertainties squared (RSS)
Open the catalog to page 98003 Technical Specifications Swept Signal Generator Control The Model 8003 Precision Scalar Network Analyzer can control the Giga-tronics 2500B series Microwave Signal Generators covering 10 MHz to 40 GHz, as well as several swept microwave signal generators from other manufacturers. Compatible Signal Generators Giga-tronics 2500B Series Microwave Signal Generator System Integrated: The Model 8003 Precision Scalar Network Analyzer can control the Giga-tronics 2500B series Microwave Signal Generators covering 10 MHz to 40 GHz, as well as several swept microwave signal generators from other...
Open the catalog to page 10Ordering Information Giga-tronics has a network of RF and Microwave instrumentation sales engineers and a staff of factory support personnel to help you find the best, most economical instrument for your specific applications. In addition to helping you select the best instrument for your needs, our staff can provide quotations, assist you in placing orders, and do everything necessary to ensure that your business transactions with Giga-tronics are handled efficiently. Model Number Microwave Scalar Network Analyzer (includes three 20954-001 sensor cables) Power Sensor Options: 20954-001 1.5...
Open the catalog to page 11©2012 Giga-tronics Incorporated. All Rights Reserved. All trademarks are the property of their respective owners.