UNIVERSAL POWER METERS
Open the catalog to page 1The Capabilities to Test Today’s Sophisticated Communications Systems The Giga-tronics 8650A Series Universal Power Meters have the extensive measurement capabilities and unique features required to tude modulated during the test today’s sophisticated pulse ‘on’ period — such as communications systems TDMA signals. faster and more accurately. Using the exclusive Burst Average Power mode (BAP), TDMA the average power reading in The 8650A can automatically the pulse burst is automatimeasure the average power cally measured between the of pulse modulated signals or 3 dB points. Therefore, the...
Open the catalog to page 2Giga-tronics 8650A Features and Specications CDMA The 8650A has the wide, 80 dB single sensor dynamic range required for CDMA signal open-loop tests, the speed you need to quickly measure power during closed-loop tests, and the 10 MHz bandwidth needed to test third-generation CDMA signals. AVERAGE POWER INSTANTANEOUS PEAK POWER You can also measure the instantaneous peak power level of a pulse modulated signal with the 8650A. SELECTED SAMPLE POINT 8650A lets you display the A built-in delay line lets you highest instantaneous power trigger a few nanoseconds measured from the time the ahead...
Open the catalog to page 3The Features to do the Job Faster, Easier and More Accurately HOLD HOLD Or use our BURST START AND exclusive fast END EXCLUDE HOLD HOLD buffered The exclusive burst start and CREST HOLD FACTOR (dB) AVG. mode to end exclude capabilities of (RESET) TIME further the 8650A allow you to reduce processor overhead exclude the beginning or end CREST FACTOR of a burst when measuring The crest factor capability of and capture over 26,000 the average burst power. the 8650A displays the ratio readings per second. Incredible of the maximum peak power BURST WIDTH (peak hold) measurement to speed for CW...
Open the catalog to page 4Accuracy Audit Unrivaled Accuracy and Built-In Calibration The Accuracy Audit table lists the signicant uncertainties of an absolute power measurement. The accuracy of the 8650A combined with the 80301A sensor is compared to a typical thermocouple sensor/meter combination at +20 dBm, 0 dBm, and –30 dBm (the dynamic limit of the thermocouple sensor). The uncertainty comparison at –30 dBm illustrates the accuracy advantage of a wide dynamic sensor, even when the full 90 dB dynamic range is not utilized. +20 dBm Frequency = 1 GHz; Source Giga-tronics uses diode sensors exclusively to provide...
Open the catalog to page 5Giga-tronics power meter architecture provides for a broad choice of functional sensors. Just by changing a sensor,you can measure CW power,pulse power,and the peak and average power of TDMA,GSM and CDMA signals faster,more accurately,and over a wider range. THE FASTEST CW MEASUREMENTS Giga-tronics 80300A Series CW Power Sensors let you measure CW power from 10 MHz to 40 GHz at more than 1,750 readings per second over GPIB. Measure up to 90 dB with a single sensor, and select from a variety of high power sensors, up to 50 W. PULSE POWER MEASUREMENTS Attach a Giga-tronics 80350A Series Peak...
Open the catalog to page 6Sensor Measurement Capabilities Signal Type CW Power Level Amplitude Modulation Rate, Power Range Two-Tone Maximum Separation Between Carriers Pulse Modulation Burst with Modulation fm = modulation rate > 200 µs Pulse Width fm < 40 kHz, > 200 µs Pulse Width; –40 to +20 dBm fm > 40 kHz, > 200 µs Pulse Width; –40 to –20 dBm > 300 µs Pulse Width fm < 1.5 MHz, > 300 µs Pulse Width; –40 to +20 dBm fm > 1.5 MHz, > 300 µs Pulse Width; –40 to –20 dBm > 100 µs Pulse Width fm < 10 MHz, > 100 µs Pulse Width; –30 to +20 dBm fm > 10 MHz, > 100 µs Pulse Width; –30 to –20 dBm MODULATED POWER MEASUREMENTS...
Open the catalog to page 7SEE FOR YOURSELF The 8650A incorporates a 3.72” wide by 2.15” high Liquid Crystal Display (LCD) with 240 x 120 dot resolution, 0.38 mm dot pitch, and Cold Cathode Fluorescent Lamp (CCFL) back light for maximum detail and optimum viewing. The large display lets you see more information. And the display works in tandem with the meter controls to let you view menu selections and see your input data as you enter it. You can view calibration information, select a standard mode, setup and recall precongured, custom modes, and set measurement points and durations. Each sensor uses an EEPROM to...
Open the catalog to page 8View the mean power and standard deviation of the modulated signal over a time period of interest. Standard deviation offers an alternative descriptive analysis of the power variation when compared to the traditional crest factor. The Cumulative Distribution Function (CDF) shows the percentage of time a signal is below a selected power level. The x axis displays the amount of power at the selected level, measured in dBm, and the y axis displays the percentage of time the power is at or below the power specied by the x axis. The Complementary Cumulative Distribution Function (CCDF) reorients...
Open the catalog to page 9Giga-tronics CW Power Sensor Selection Guide Frequency Range/ Power Range 200 mW CW Power Sensors Maximum Power Power Linearity 4 (Frequency > 8 GHz) Low VSWR CW Power Sensors 80310A Giga-tronics Peak Power Sensor Selection Guide Frequency Range/ Power Range 200 mW Peak Power Sensors Maximum Power Power Linearity 4 (Frequency > 8 GHz) Test Port –20 to +0.0 dBm, Peak –30 to +0.0 dBm, CW 5 W Peak Power Sensor 5, 7 80351A 25 W Peak Power Sensor 6, 7 80352A 50 W Peak Power Sensor 6, 7 80355A Giga-tronics Bridge Selection Guide Frequency Range/ Maximum Power Range Power Precision CW Return Loss...
Open the catalog to page 10Giga-tronics Modulation Power Sensor Selection Guide (fm < 40 kHz) Frequency Range/ Power Range Maximum Power Power Linearity 4 (Frequency > 8 GHz) 200 mW Modulation Power Sensors 80401A –67 to +20 dBm Low VSWR Modulation Power Sensor 80410A –64 to +26 dBm 1 W Modulation Power Sensor 80420A –57 to +30 dBm 5 W Modulation Power Sensor 2 80421A 25 W Modulation Power Sensor 3 80422A 50 W Modulation Power Sensor 80425A Giga-tronics Modulation Power Sensor Selection Guide (fm < 1.5 MHz) Frequency Range/ Maximum Power Range Power 200 mW Modulation Power Sensors Power Linearity 4 (Frequency > 8...