Overview: The document provides technical specifications, operational procedures, and safety guidelines for UV Exposure Boxes designed for exposing UV-light sensitive materials such as photo-sensitive films and plates. These devices are suitable for use in various environments including laboratories, schools, and small factories.
Specifications: The UV Exposure Box is constructed with anodized aluminum profiles and features electronic ballasts compliant with EN60929 standards. It uses special fluorescent lamps (ACTINIC) with a UV-A wavelength of 350-400 nm, ensuring even illumination across the lighting area. The device includes an electronic timer with selectable ranges from 1-600 seconds or 1-100 minutes, operated via a single knob and displayed on a seven-segment LED.
Technical Data: Two models are specified: Model 140007 with a mounting area of 160 x 250 mm and Model 140017 with 240 x 365 mm. Power consumption is 32 W and 60 W respectively, with UV tubes of 8 W and 15 W. The devices operate at a power supply of 230V (50-60Hz).
Operational Procedures: The device should be placed on a stable, horizontal surface in a darkened room. It is crucial to follow safety instructions, including ensuring the device is not operated by children or untrained individuals. The exposure process involves attaching films under aluminum strips, setting the exposure time, and starting the exposure with the lid closed.
Maintenance: The UV Exposure Box requires minimal maintenance, primarily involving the replacement of lamps after approximately 1000 hours of use. Cleaning should be done with standard glass cleaner, avoiding scratches or contamination on the glass plate.
Safety Guidelines: The document emphasizes the importance of not starting the exposure process before the lid is closed to prevent UV-A radiation exposure, which can be harmful to skin and eyes. The device must be disconnected from the power supply before opening the housing for maintenance.
Declaration of Conformity: The UV Exposure Boxes comply with the EC-Directive 2006/95/EG and EMI-Directive 2004/108/EG, with quality assurance certified under ISO 9001:2008.
Spare Parts: Replacement UV lamps are available with part numbers 410007 for 8W lamps and 410017 for 15W lamps.
See more

Catalog excerpts

UV-Exposure Box-1

UV-Exposure Box ...for expose UV-ligth sensitive foils and plates UV Exposure Boxes shall used for exposure foto sensitive materials such as base materials, printed plates, front plates or foto sensitive films. Using the devices is very easy and user-friendly. The oscillator-based electronic timer allows the precise adjustment of the exposure time, only with 1-knob operation (mode, time, Start/Stop). The seven-segment LED display is showing the adjusted time and while the device is active the remaining time. The Exposure Boxes are designed for using in dry rooms, schools, living rooms, office, as well in laboratory and small factories Electronic ¢ ballast according EN60929, EN-EC 03, EI=A2, no stroboscopic effect, no flicker, power factor >0,92 Grindet glass plate with high UV transparency for ¢ UV-A wave length Leading bar ¢ for exact adjustment of films and plates Special flourescent lamps (type: ACTINIC), wave ¢ length 350 - 400nm (UV-A) Evenly illumination all of the lighting area ¢ Technical Data Constant ¢contact pressure between 22mm cellular material in the lid and the glass plate. Item no.: Dimension (LxBxH) Mounting area Power consumption Number of UV tubes UV wave length Timer Electronic ¢ timer, selectable ranges 1-600seconds, or 1-100minutes, 1-knob handling, seven-segment LED display Subject to technical modifications without prior notice. Gie-Tec GmbH Metal housing out of anodised aluminum profiles and ¢ plates.

 Open the catalog to page 1
UV-Exposure Box-2

gie - tec 1. Starting up 1.1 Placement ATTENTION! l The UV Exposure Box is suited for ligth exposure of foto sensitiv coated materials, such as foto positive coated base material, Cobritherm, front plates and films for making printed plates. Other usings are not allowed. l is designed for power The device supply 230V (50- 60Hz) and may used only in perfect technical condition. Using the Exposure Box it´s not allowed by children and people which are not instructed. The device ought to be placed onto a horizontal, stable base (e. g. workbench, table) with the control elements pointing to the front....

 Open the catalog to page 2
UV-Exposure Box-3

gie - tec 1.4 Operation of the timer With the built-in-timer, you can adjust the ligthing duration of the UV-lamps. Time setting is possible in SecondMode or MinuteMode. Switch on the device, the timer is in “SecondMode”. Thereby the ON-time can be adjusted between 1 sec and 9min50sec. 3-digit, 7-Segment LED Display (remaining time) Display 3 Rotating knob and key combination to adjust mode, time and Start/stop These dots are shining only in MinuteMode This dot is shining when lid is open (only in device #140007 1000) Adjustment of exposure time After switch-on the device or plug in the power...

 Open the catalog to page 3
UV-Exposure Box-4

gie - tec Information of Safety and Risc: Declaration of Conformity of Exposure Boxes according EC-Directive 2006/95/EG Don´t start exposing time before lid of exposure box is closed. Gie-Tec GmbH An der Schlierbach 18 36132 Eiterfeld UV-A radiation can be dangerous for skin and eyes. Description and Identification of Device: UV Exposure Box 2 Art. Nr. 140017 These device is produced in accordance to following directives Low Voltage Directive (2006/95/EG) EMI-Directive (2004/108/EG) Quality Safety System Place, Date Rainer Giebel, Managing Director Gie-Tec GmbH UV lamps 230V/8W) for Exposure...