1. Catalogs
  2. GHT Solutions Ltd
  3. Technical Information

Technical Information

Technical Information
1 / 16 PagesView full catalog

Technical Information

Product catalog summary
Introduction
This document provides technical information on GHT's advanced geothermal technology solutions, effective from April 1, 2025. The focus is on the GHT unit, a top-tier pre-heater/cooler for HRV/ERV systems, designed for improved efficiency and sustainability.
Technology Overview
Summer Technology: Utilizes ground coolness at depths of 1.5m to 2m to cool incoming air, enhancing comfort and reducing energy consumption.
Winter Technology: Uses ground heat to warm incoming air, ensuring ventilation unit efficiency without the need for de-icing, thus saving energy and reducing fossil fuel reliance.
Importance of Air Filters
Regular monitoring and replacement of air filters are crucial for maintaining air quality and system efficiency. Clean filters trap pollutants, enhance system performance, extend equipment lifespan, and comply with ISO16890 standards. Recommended replacement is every 3-6 months.
Geothermal Energy Systems
Horizontal Ground Collectors: Installed at 1.5–2.5 meters depth, these collectors use ground heat for efficient heating and cooling, offering energy efficiency and eco-friendliness.
Vertical Boreholes: Drilled to depths of 50 to 200 meters, these boreholes provide high efficiency and are suitable for limited land spaces, reducing energy consumption and CO2 emissions.
Technical Specifications
The document details specifications for various GHT units (G-2000 to G-8000), including weight, dimensions, power consumption, heating and cooling power, and airflow capacity. It also includes information on glycol flow and pressure drop, operating temperatures, and connection types.
Product Range
GHT offers a range of products designed for energy efficiency and air quality improvement, suitable for residential and commercial applications. The catalog includes detailed technical specifications and pricing information.
Contact Information
GHT SOLUTIONS Ltd, 18; Block 19 Vincenti Bld, Strait Street, VLT 1432, Valletta, MALTA. Website: www.ghtsolution.com
See more

Catalog excerpts

Technical Information-1

Technical Information INTERNATIONAL 2025 Valid from 1st of April 2025 SUSTAINABLE SOLUTIONS FOR YOUR COMFORT

 Open the catalog to page 1
Technical Information-2

Evolution Over two years leading up to 2014, we focused on research and development, which led to the advanced technology in our GHT unit. GHT stands for Geothermal Technology and represents a top-tier pre-heater/ cooler for HRV/ERVs. Steel box designing into thermal bridge free EPP enclousure. This evolution has resulted in a lighter, better-insulated, and more efficient solution, making our GHT unit stand out in the market.

 Open the catalog to page 2
Technical Information-3

Technology SUMMER The ground-source heat exchanger leverages ground coolness, with temperatures about 12°C (54°F) at depths of 1,5m to 2m (5 to 8ft), to cool incoming air. Increased comfort through cooled air Cooled incoming air will prevent the building from overheating in summer Energy saving Reduction of noise from open windows Less outside pollution influence on inside climate

 Open the catalog to page 3
Technical Information-4

During extremely cold winters, the ground-source heat exchanger heats incoming air to ensure the proper functioning of the ventilation unit. It utilizes ground heat at depths of 1,5m to 2m (5 to 8ft), where temperatures range around +6°C (+40°F). • Brine defroster and heat recovery unit achieves high efficiency pre-heating • Ventilation unit is protected from freezing • No de-icing function in the ventilation unit is required and year-round operation is possible • Energy saving • Non-reliance on fossil fuels

 Open the catalog to page 4
Technical Information-5

No fresh air without filtersWhy Regular Monitoring and Replacement of Air Filters is Essential Air filters play a crucial role in maintaining indoor air quality and ensuring the efficient operation of ventilation systems. Here are the key reasons why regular attention to air filters is necessary: • Improved Air Quality: Clean filters effectively trap dust, allergens, and pollutants, providing fresher and healthier air for occupants. Neglected filters can lead to recirculation of contaminants, negatively affecting well-being. • Optimal System Performance: A clogged filter restricts airflow, forcing...

 Open the catalog to page 5
Technical Information-6

Horizontal Ground Collectors: Essence and Operating Principle Horizontal ground collectors are an essential component of geothermal energy systems, providing an efficient and environmentally friendly solution for heating and cooling. These collectors are installed beneath the ground surface, typically at a depth of 1.5-2.5 meters, where the temperature remains stable and suitable for heat exchange. Key Features and Operating Principle: • Energy Source: Horizontal collectors utilize ground heat, which accumulates from solar energy and the Earth's internal heat. This energy is transferred to the...

 Open the catalog to page 6
Technical Information-7

Source of Energy Vertical Boreholes: Essence and Operating Principle Vertical boreholes are another essential component of geothermal energy systems, offering high efficiency and broad applicability in various climatic conditions. This method involves drilling deep boreholes into the ground to access stable underground temperatures suitable for heat exchange. Key Features and Operating Principle: • Energy Source: Vertical boreholes extract the Earth's internal heat, which is transferred to the geothermal system using a heat carrier (e.g., glycol mixture or antifreeze). • Installation Depth: Borehole...

 Open the catalog to page 7
Technical Information-9

Description Ground-source heat exchanger is specifically developed for use with heat recovery ventilation units. It features exceptional energy efficiency, high heating and cooling capacity, and a high coefficient of performance (COP). The casing, fully made of EPP, ensures thermal insulation and eliminates thermal bridges. Additionally, the lightweight design allows for easy installation on-site.

 Open the catalog to page 9
Technical Information-11

At GHT, we are dedicated to providing innovative and energy-efficient solutions for ventilation and air quality improvement. Our products are designed with precision, sustainability, and performance in mind to meet the needs of both residential and commercial applications. In this catalog, you will find a comprehensive selection of our products, detailed technical specifications, and transparent pricing to help you make informed decisions. From top-tier preheater/cooler for HRV/ERVs to high-performance filter boxes, every product reflects our commitment to quality and reliability. We invite you...

 Open the catalog to page 11
Technical Information-12

G-2000/G-2001 DESCRIPTION Heating power 2.48kW, cooling power 2.62 kW; Air flow up to 300m³/h - 175CFM Supply air temp. summer [°C] 20 15 Solution for HRV/ERV with airflow up to 300m³/h - 175CFM Glycol temp. winter +6°C/42.8°F, summer +12°C/53.6 °F Technical information 2025, subject to change wit

 Open the catalog to page 12
Technical Information-13

G-4000/G-4001 DESCRIPTION Heating power 2.83kW, cooling power 4.01 kW; Air flow up to 450m³/h - 265CFM Supply air temp. summer [°C] 20 15 10 G-4000 Solution for HRV/ERV with airflow up to 450m³/h - 265CFM Glycol temp. winter +6°C/42.8°F, summer +12°C/53.6 °F Technical information 2025, subject to change

 Open the catalog to page 13
Technical Information-14

G-6000/G-6001DESCRIPTION Heating power 5.44kW, cooling power 6.02kW; Air flow up to 600m3/h - 350CFM Supply air temp. summer [°C] Glycol temp. winter +6°C/42.8°F, summer +12°C/53.6 °F Technical information 2025, subject to change without prior notice.

 Open the catalog to page 14
Technical Information-15

G-8000/G-8001 DESCRIPTION Heating power 8.1kW, cooling power 8.72kW; Air flow up to 1000m³/h - 600CFM Supply air temp. summer [°C] 20 15 G-8000 Solution for HRV/ERV with airflow up to 1000m³/h - 600CFM Glycol temp. winter +6°C/42.8°F, summer +12°C/53.6 °F Technical information 2025, subject

 Open the catalog to page 15
Technical Information-16

Contacts GHT SOLUTIONS" Ltd 18; Block 19 Vincenti Bld, Strait Street, VLT 1432, Valletta, MALTA www.ghtsolution.com

 Open the catalog to page 16
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.