Introduction
This installation manual is for the PureFlow 200 inline filter box, effective from January 1, 2026. It is crucial to read and retain this manual for future reference. Installation must be performed by authorized personnel only.

Product Description
The PureFlow 200 is made from Expanded Polypropylene (EPP), offering excellent thermal and sound insulation. It accommodates up to three filters, with combinations including ISO Coarse 75% / MERV 8, ePM1 60% (F7) / MERV 13, or Carbon 250g F7 (ePM2.5 65%). Filters should be replaced every 3 to 6 months.

Warranty and Liability
The warranty period is 2 years from delivery, covering material or construction defects. It is void if non-original parts are used, improper installation occurs, or unauthorized modifications are made. Maintenance must be performed by an authorized plumber.

Safety Instructions
Follow all safety instructions and local regulations. Symbols in the manual indicate risks of physical injury, unit damage, or failures if instructions are not followed.

Shipping and Package Contents
Do not remove packaging until installation. Ensure a 0.5-meter clearance for maintenance. Package includes one PureFlow 200 filter box and two DN200 → DN160 adapters.

Installation
Connect air ducts to DN 200 or DN 160 connections, ensuring airtight seals. Periodic maintenance is necessary for proper system function.

Maintenance
End users can replace filters and clean the unit. Filters should be replaced at least every six months, or more frequently depending on air pollution. Use only genuine filters from the manufacturer.

Contact Information
GHT SOLUTIONS Ltd, 18; Block 19 Vincenti Bld, Strait Street, VLT 1432, Valletta, MALTA. Website: www.ghtsolution.com
See more

Catalog excerpts

Installation manual INTERNATIONAL 2026 Valid from 1st of January 2026 PureFlow 200PureFlow 200-1

SUSTAINABLE SOLUTIONS FOR YOUR COMFORT • Please read this instruction manual completely before installing the product. INTERNATIONAL 2026 • Installation work must be performed by authorized personnel only. Valid from 1st of January 2026 . Please retain this installation manual for future reference after reading it thoroughly.

 Open the catalog to page 1
Installation manual INTERNATIONAL 2026 Valid from 1st of January 2026 PureFlow 200PureFlow 200-2

Safety Precautions Thank you for purchasing Pureflow 200 inline filter box READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND USING THE EQUIPMENT! THIS INSTRUCTION HAS BEEN MADE WITH THE GREATEST CARE. HOWEVER, THIS INSTRUCTION CONFERS NO RIGHTS. WE RESERVE THE RIGHT TO CHANGE ALL OR PART OF THE CONTENTS OF THIS INSTRUCTION WITHOUT PRIOR NOTICE. This instruction contains all information necessary for an optimal installation and startup by skilled personnel. It is absolutely important to follow the instructions in this manual very thoroughly in order to guarantee the correct function of the...

 Open the catalog to page 2
Installation manual INTERNATIONAL 2026 Valid from 1st of January 2026 PureFlow 200PureFlow 200-3

The filter box has been developed and produced for use in so called comfort ventilation systems and Controlled-environment agriculture (CEA). Any other use is considered an improper use and can lead to damages to equipment and persons; the manufacturer is not liable in such cases. The manufacturer is not liable for any damages caused by: • non-compliance of safety, operation and maintenance notes; • improper installation; • defects that occur due to improper connection or use and decontamination of the system; • after the warranty period has elapsed; • normal wear and tear. Please obey the safety...

 Open the catalog to page 3
Installation manual INTERNATIONAL 2026 Valid from 1st of January 2026 PureFlow 200PureFlow 200-4

Checking the Package Content In case of damages or incompleteness of the product delivered, please contact the supplier immediately. Package contents are: • • Installation Mounting Please assure a minimum clearance of 0.5 meter for maintenance purposes in front of the filterbox. Connect the air ducts to the corresponding duct connections DN 200 (8") or DN 160 (6") if adapters are used. Seal all air duct connections ensuring air tightness.

 Open the catalog to page 4
Installation manual INTERNATIONAL 2026 Valid from 1st of January 2026 PureFlow 200PureFlow 200-5

5 MaintenancePeriodic maintenance is absolutely necessary for the system to run ■ * properly. The following maintenance work can be carried out by the end user: It depends on the operating conditions how often the filter has to be replaced. We recommend changing the filters when changing the filters of the heat recovery unit. Replace the filter (at least) every six months. In case of carbon filter - depending on air pollution 1 Stop the ventilation unit or fan; 2 Open front door, pull out filter; 4 Close front door. Only use genuine filters provided by the manufacturer. Installation manual

 Open the catalog to page 5
Installation manual INTERNATIONAL 2026 Valid from 1st of January 2026 PureFlow 200PureFlow 200-6

Contacts "GHT SOLUTIONS" Ltd 18; Block 19 Vincenti Bld, Strait Street, VLT 1432, Valletta, MALTA www.ghtsolution.com

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.