modular electrostatic filters • Centralized and localized systems for fumes and oil mists extraction from processing on machine tools • Air effluents with temperatures above 65 °C • Welding fumes and fumes from metal stamping • Air effluents with powders and chips • Oily mist and vapors from heat treatments • Rubber and plastic molding and plasticizing operations • Aluminum die casting operations FEATURES • Lower energy consumption and lower running costs thanks to the low pressure drops OPERATION PRE-FILTRO PRE-FILTER SEZIONE IONIZZANTE IONIZING SECTION SEZIONE COLLETTRICE COLLECTING SECTION POST-FILTRO POST-FILTER • Simple and economical maintenance, reduced to a simple soaking wash with water and detergent • Maintenance at scheduled and constant intervals, combined with the use of appropriate substances, guarantees an unlimited duration • The oily particles after being sucked and retained by the electrostatic filter, drain due to their own weight, at the same time cleaning the filter • Abatement of suspended particles up to 0.01 micron in diameter STANDARD SUPPLY • The exhalations arrive at the first battery of the electrostatic filter, consisting of a mechanical pre-filter, which stops the coarsest particles and makes the air flow uniform • The particles are then electrically charged through the ionizing cell and then broken down in the collector cell by the ground plates • The post-filter evens out the outgoing air flow • Filter module with ionizing cell, collecting cell, metal prefilter and postfilter and transformer • Fan and inlet chamber (GGS VENT and GGS T-VENT versions) GGE srl | Rio Saliceto (Reggio Emilia) Italy | www.gge.eu | info@gge.eu | tel. +39 0522 738411 | Texts, technical data and pictures are purely for guidance and do not represent contractual commitment for GGE srl | Da
Open the catalog to page 1modular electrostatic filters TECHNICAL DATA Model Pre/Post filters Ionizing / collecting cells GGS VENT [With ventilator, box and air inlet chamber] GGS10/VENT-07 GGS T/VENT [Tandem (2 filters combined one behind the other) with fan, box and air inlet chamber] GGS10-T/VENT-07 The suitability of the type of filter, the air flow rate and the type of cleaning must be checked according to any regulatory restrictions in force in the place of installation. Ionizer/collector output voltage: 12000/6000V It is possible to reach higher flow rates by combining the modules (example: GGS80/C + GGS80/C...
Open the catalog to page 2modular electrostatic filters GGE srl | Rio Saliceto (Reggio Emilia) Italy | www.gge.eu | info@gge.eu | tel. +39 0522 738411 | Texts, technical data and pictures are purely for guidance and do not represent contractual commitment for GGE srl | Data sheet updated on July 4, 2023
Open the catalog to page 3modular electrostatic filters PRODUCTIONS GGE srl | Rio Saliceto (Reggio Emilia) Italy | www.gge.eu | info@gge.eu | tel. +39 0522 738411 | Texts, technical data and pictures are purely for guidance and do not represent contractual commitment for GGE srl | Data sheet updated on July 4, 2023
Open the catalog to page 4All GGE srl catalogs and technical brochures
-
TM EVO - GGE data sheet
2 Pages
-
AVO - GGE data sheet
1 Pages
-
BLIND - GGE data sheet
1 Pages
-
NERTI - GGE data sheet
1 Pages
-
RED CYCLONE - GGE data sheet
1 Pages
-
T REEL - GGE data sheet
1 Pages
-
WALLA - GGE data sheet
1 Pages
-
AR - GGE data sheet
5 Pages
-
AUTOVENT - GGE data sheet
1 Pages
-
MONO-DOPPIO - GGE data sheet
1 Pages
-
ZINCO D - GGE data sheet
2 Pages
-
ZINCO DR - GGE data sheet
1 Pages
-
ZINCO Q - GGE data sheet
1 Pages
-
ZINCO SR - GGE data sheet
1 Pages
-
ZB E - GGE data sheet
1 Pages
-
ZB POL JET - GGE data sheet
2 Pages
-
LOC - GGE data sheet
1 Pages
-
AIRSOL CAR - GGE data sheet
1 Pages
-
CARVENT - GGE data sheet
1 Pages
-
DCE - GGE data sheet
2 Pages
-
DEVID ONE - GGE data sheet
1 Pages
-
DOT VENT - GGE data sheet
1 Pages
-
ECO DCE - GGE data sheet
1 Pages
-
EURO POLVOS - GGE data sheet
2 Pages
-
GUAPP - GGE data sheet
1 Pages
-
MINI POLVOS - GGE data sheet
1 Pages
-
POLVOS - GGE data sheet
3 Pages
-
TM F - GGE data sheet
1 Pages
-
AIRSOL CARB - GGE data sheet
5 Pages
-
AIRSOL DRY - GGE data sheet
4 Pages
-
AIRSOL OIL - GGE data sheet
4 Pages
-
AIRSOL POL - GGE data sheet
3 Pages
-
BUBBLER - GGE data sheet
2 Pages
-
BUB VENT - GGE data sheet
2 Pages
-
CARB C - GGE data sheet
3 Pages
-
CARB - GGE data sheet
4 Pages
-
CICL - GGE data sheet
2 Pages
-
SCRUBBER - GGE data sheet
2 Pages
-
RAF Q - GGE data sheet
2 Pages
-
RAF PC - GGE data sheet
2 Pages
-
RAF PS - GGE data sheet
2 Pages
-
POLJET F - GGE data sheet
3 Pages
-
FINPOL HZ - GGE data sheet
3 Pages
-
FINPOL F - GGE data sheet
4 Pages
-
FINPOL ATEX - GGE data sheet
3 Pages
-
POWER JET - GGE data sheet
5 Pages
-
GGE srl - Technical Catalogue 2023
194 Pages
-
MTV G – GGE data sheet
2 Pages
-
PERMA ARM – GGE data sheet
5 Pages
-
MINI EL – GGE data sheet
1 Pages
-
ZB – GGE data sheet
2 Pages
-
ZB POL – GGE data sheet
2 Pages
-
ZB POL F – GGE data sheet
2 Pages
-
ZB SAND – GGE data sheet
1 Pages
Archived catalogs
-
Mechanical Industry
12 Pages
-
COMPLEMENTS AND ACCESSORIES
28 Pages
-
SAFETY
8 Pages
-
FOOD INDUSTRY
4 Pages
-
DEODORIZATION
12 Pages
-
VENTILATION
16 Pages
-
SPRAY PAINTING
8 Pages
-
DEDUSTING
52 Pages
-
WHEEL-MOUNTED FILTERS
16 Pages
-
HOBBY PRODUCTS
12 Pages