DEODORIZATION
12Pages

{{requestButtons}}

Catalog excerpts

DEODORIZATION - 2

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - Biotechnologies Smells in bio con version plants Composting plants, like all the plants where great masses of organic substances are managed and transformed, are the cause of bad smell emissions. All the processes of...

Open the catalog to page 2
DEODORIZATION - 3

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - BIOFILTERS Bio-filtration is a technology used to treat the gaseous emissions which are obliged to pass through a biologically active porous bed. The system is, in reality, a bed filled up with materials such as...

Open the catalog to page 3
DEODORIZATION - 4

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - Bio-filters CONTROL TECH NOLOGIES AND DUST SUPP RESSION It is advisable that the plants using important quantities of fermentable material are situated at an adequate distance from the urban habitats (< 300-600 metres)...

Open the catalog to page 4
DEODORIZATION - 5

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - Bio-filters V.O.S. puri fication (Volatile Organic Substances) The theory of purification with bio-filters is based on the concept of bio-film used to describe processes of degradation in water systems. The pollutant...

Open the catalog to page 5
DEODORIZATION - 6

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - Bio-filters BIOMAT “BioMat” is made up of a bio-filtering mixture according to our formulation, produced with a mixture of barks from broadleaved trees, properly defibrated and mixed up with ecologic peat, with...

Open the catalog to page 6
DEODORIZATION - 7

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - SCRUB Scrubbers DESCRIPTION Odors are mostly spread because they are transported by supports with minimum dimensions (micro-dusts which are as small as thousandths/hundredths/tenths of micron) or by gasifying molecules....

Open the catalog to page 7
DEODORIZATION - 8

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - SCRUB Scrubbers SCH EME OF A SCRUBBER WITH INPU T OF REAGENT 01. Polypropylene solution hold-up tank 02. Piston meter pump for the reagent 03. Polluted air input 04. Filling bodies 05. Solution dispensing nozzles 06....

Open the catalog to page 8
DEODORIZATION - 9

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - SCRUB Scrubbers plants for the trans port of fluids In bio-conversion plants fluids are transported through stainless steel or polypropylene piping. The use of sheet zinc pipes showed considerable limits with regard to...

Open the catalog to page 9
DEODORIZATION - 10

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - 10 DESCRIPTION For effluents with low concentrations of volatile organic substances (V.O.S.) it is advantageous to use the disposable absorbing filters we produce instead of combustion or regeneration systems. This type...

Open the catalog to page 10
DEODORIZATION - 11

GGE srl - via Turati, 11 - 42010 Rio Saliceto (Reggio Emilia) - Italy - tel. +39 0522.738411 - fax. +39 0522.649714 - www.ggegroup.com - info@ggegroup.com Data contained therein are indicative and can change without previous notice. Flow rate and pressure values can have a tolerance ±10%. Noise values can have a tolerance ±3 dB(A). DEODORIZATION 2007 technical catalogue DD - 11 CARB Activated charcoal filters TECH NICAL DATA Model Max. flow rate (m3/h) Number of cartridges Thickness of cartridges (mm) Total volume of carbon (m3) Total average surface (m2) Contact time (sec) Crossing speed...

Open the catalog to page 11

All GGE srl catalogs and technical brochures

Archived catalogs

  1. SAFETY

    8 Pages

  2. VENTILATION

    16 Pages

  3. DEDUSTING

    52 Pages

  4. HOBBY PRODUCTS

    12 Pages