Catalog excerpts
Modular air filter units for spray painting STANDARD SUPPLY • Plants for the treatment of effluents from painting operations • Pocket filter (DRY DT only) • Treatment of the expulsion air of the painting areas, to stop the solid part of the overspray • Prefiltration in systems with subsequent filtration stages that must be protected from dust pollution (for example activated carbon filters) • PAINT STOP filter RESTRICTIONS • Air effluents with temperatures above 60 °C • Plastic fumes, packing fumes, flammable powders FEATURES • Sturdy construction in galvanized sheet and painted sheet • Calming air chamber with inspection hatch • AIRSOL DRY D: filtration with Paint Stop with cardboard (DRY D) or metal frame (DRY DZ) • AIRSOL DRY DT: first filtration stage with Paint Stop with cardboard (DRY DT) or metal frame (DRY DTZ); second filtration stage with class F7 pocket filter (EN 779) • Additional filtration stage with HEPA filter, H13 class (optional) • Inspection hatch • Modularity of the AIRSOL system: the filters can be combined in parallel to achieve very high flow rates GGE srl | Rio Saliceto (Reggio Emilia) Italy | www.gge.eu | info@gge.eu | tel. +39 0522 738411 | Texts, technical data and pictures are purely for guidance and do not represent contractual commitment for GGE srl | Data she
Open the catalog to page 1Modular air filter units for spray painting TECHNICAL DATA Modules Stage 1 acrylic prefilter Filtering surface STERIL STERIL STERIL AIRSOL DRY D [with cardboard frame] 1000 x1000 x 1000 x 860 860 860 AIRSOL DRY DZ [with galvanized frame] The suitability of the type of filter, the air flow rate and the type of cleaning must be checked according to any regulatory restrictions in force in the place of installation. (*) suggested maximum flow rate could decrease, even by a lot, depending on the pollutant. Ask our technical department. The COMPONENTS DRY/DT (+800(+800 per a tasche) DRY/DT (+800...
Open the catalog to page 2STERIL STERIL STERIL 1000 x 860 Stage 1 acrylic prefilter Modular air filter units for spray painting TECHNICAL DATA AIRSOL DRY DT [with cardboard frame] AIRSOL DRY DTZ [with galvanized frame] AS1/DTZ The suitability of the type of filter, the air flow rate and the type of cleaning must be checked according to any regulatory restrictions in force in the place of installation. (*) suggested maximum flow rate could decrease, even by a lot, depending on the pollutant. Ask our technical department. The DRY/DTDRY/DT (+800 pertasche)a tasche) DRY/DT (+800 per filtro a (+800 MODULES per filtro a...
Open the catalog to page 3Modular air filter units for spray painting OPTIONAL SPARE PARTS • [MN/DG/BATT/ST] Battery-powered digital pressure gauge with support bracket and filter connection • [PAN/L] PAINT STOP filter with cardboard frame • [MN/DG/24VAC] Digital pressure gauge - 24VAC power supply. (Requires preparation on control panel) • Special machines for large capacities • Additional filtration stage with HEPA filter, H13 class • Fan • [PAN/R] PAINT STOP filter with openable galvanized frame • [MN/DG/BATT] Battery-powered digital pressure gauge (without bracket or connection materials) • [BEA/3/4] Air...
Open the catalog to page 4All GGE srl catalogs and technical brochures
-
TM EVO - GGE data sheet
2 Pages
-
AVO - GGE data sheet
1 Pages
-
BLIND - GGE data sheet
1 Pages
-
NERTI - GGE data sheet
1 Pages
-
RED CYCLONE - GGE data sheet
1 Pages
-
T REEL - GGE data sheet
1 Pages
-
WALLA - GGE data sheet
1 Pages
-
AR - GGE data sheet
5 Pages
-
AUTOVENT - GGE data sheet
1 Pages
-
MONO-DOPPIO - GGE data sheet
1 Pages
-
ZINCO D - GGE data sheet
2 Pages
-
ZINCO DR - GGE data sheet
1 Pages
-
ZINCO Q - GGE data sheet
1 Pages
-
ZINCO SR - GGE data sheet
1 Pages
-
ZB E - GGE data sheet
1 Pages
-
ZB POL JET - GGE data sheet
2 Pages
-
LOC - GGE data sheet
1 Pages
-
AIRSOL CAR - GGE data sheet
1 Pages
-
CARVENT - GGE data sheet
1 Pages
-
DCE - GGE data sheet
2 Pages
-
DEVID ONE - GGE data sheet
1 Pages
-
DOT VENT - GGE data sheet
1 Pages
-
ECO DCE - GGE data sheet
1 Pages
-
EURO POLVOS - GGE data sheet
2 Pages
-
GUAPP - GGE data sheet
1 Pages
-
MINI POLVOS - GGE data sheet
1 Pages
-
POLVOS - GGE data sheet
3 Pages
-
TM F - GGE data sheet
1 Pages
-
AIRSOL CARB - GGE data sheet
5 Pages
-
AIRSOL OIL - GGE data sheet
4 Pages
-
AIRSOL POL - GGE data sheet
3 Pages
-
BUBBLER - GGE data sheet
2 Pages
-
BUB VENT - GGE data sheet
2 Pages
-
CARB C - GGE data sheet
3 Pages
-
CARB - GGE data sheet
4 Pages
-
CICL - GGE data sheet
2 Pages
-
SCRUBBER - GGE data sheet
2 Pages
-
GG SMOG - GGE data sheet
4 Pages
-
RAF Q - GGE data sheet
2 Pages
-
RAF PC - GGE data sheet
2 Pages
-
RAF PS - GGE data sheet
2 Pages
-
POLJET F - GGE data sheet
3 Pages
-
FINPOL HZ - GGE data sheet
3 Pages
-
FINPOL F - GGE data sheet
4 Pages
-
FINPOL ATEX - GGE data sheet
3 Pages
-
POWER JET - GGE data sheet
5 Pages
-
GGE srl - Technical Catalogue 2023
194 Pages
-
MTV G – GGE data sheet
2 Pages
-
PERMA ARM – GGE data sheet
5 Pages
-
MINI EL – GGE data sheet
1 Pages
-
ZB – GGE data sheet
2 Pages
-
ZB POL – GGE data sheet
2 Pages
-
ZB POL F – GGE data sheet
2 Pages
-
ZB SAND – GGE data sheet
1 Pages
Archived catalogs
-
Mechanical Industry
12 Pages
-
COMPLEMENTS AND ACCESSORIES
28 Pages
-
SAFETY
8 Pages
-
FOOD INDUSTRY
4 Pages
-
DEODORIZATION
12 Pages
-
VENTILATION
16 Pages
-
SPRAY PAINTING
8 Pages
-
DEDUSTING
52 Pages
-
WHEEL-MOUNTED FILTERS
16 Pages
-
HOBBY PRODUCTS
12 Pages