Catalog excerpts
Microtector II G460 7-gas-detector with performance test approval Performance test approved multi-gas detector (290g) Extremely loud alarm, 103 dB(A) for optimum personnel protection Full featured, rugged design (IP67) Innovative optical alarm system with colour-change display PID sensor for direct reading of toxic volatile organic compounds (VOCs) Infra-red (IR) sensors for CO2 and combustible gas (%LEL – %VOL) Wide range of additional sensors including SO2, HCN, Cl2, NH3, PH3, H2, NO, NO2, ClO2, ETO and more ▪ Highly configurable design using smart sensor Worldwide Supplier Of Gas Dete
Open the catalog to page 1Your safety is our priority The smallest all-rounder The Microtector II G460 is the world‘s smallest 7-gas detector with the following key features: With five sensor positions, the G460 offers more than previously possible in an instrument of comparable size. The main innovation of the G460 is the continuous and selective measurement of seven gases simultaneously. Thus, it warns of dangers of toxic, combustible gases and vapours, but also oxygen deficiency and surplus. With a wide range of sensors and accessories, the G460 satisfies all applications and requirements. all over Europe voted...
Open the catalog to page 2Field-proven features Innovative alarm system Alarm situations are notified with distinct multi-frequency alarm sounds. The 103 dB(A) audible alarm is the loudest available on the market today. The unique “traffic light” visual alarm of the G460 helps the user to quickly and simply understand alarm status. In alarm, the whole instrument display changes colour as shown below: Red High alarm Red alert! Yellow/Orange Low alarm Caution! Reversible display always visible tions, so working life and maintenance requirements are minimized. This gives the use far lower servicing and operating costs....
Open the catalog to page 3Accessories for every application sewage. The existing battery unit of the G460 can be replaced with an integrated lamp battery unit if necessary. Thus, an easy upgrade is guaranteed. Flexible power supply Also, the battery packs used in the pump are directly interchangeable with the instrument battery packs, giving still more flexibility. The G460 NiMH-battery pack gives an operation time of up to 30 hours (depending on sensor configuration), and minimum 8-9 hours. If battery capacity is low, an automatic battery alarm is triggered. Two smart caps A smart calibration cap is used for manual...
Open the catalog to page 4High performance sensors mean maximum safety Multi-channel IR sensors Using GfG´s unique, patented multi-IR sensor both carbon dioxide (CO2) and flammable gases can be measured at the same time. The IR sensor uses up to 4 detectors. Sensor Type Sensor Position Carbon Dioxide C02 and Methane Methane Carbon Dioxide and Methane, Propane, Nonane Carbon Dioxide and Methane, Propane, Nonane Carbon Monoxide CO with low H2-sensitivity Carbon Monoxide CO and Hydrogen Sulphide H2S There are STEL (Short-Term Exposure Limit) and TWA (Time-Weighted Average) exposure limits set by international law for...
Open the catalog to page 5Technical Data Humidity: Operation and storage: 5 .. 95 % r. h. Detection principle Electrochemical (EC) (up to 4): Toxic gases and oxygen (ppm / %Vol) Pressure: Operation and storage: 700 .. 1300 hPa Catalytic combustion (CC): Flammable gases and vapours (to 100 %LEL) Photo Ionisation (PID): 10,6 eV Toxic gases and vapours (ppm) Calibration gas: Isobutylene Infrared (IR): Carbon dioxide (%Vol / ppm) Flammable gases and vapours (100 %LEL and %Vol) Expected sensor lifetime: Up to 5 years, depending on sensor Test gas supply: Diffusion, attachable, electrical pump for up to 10 hours...
Open the catalog to page 6All GfG catalogs and technical brochures
-
Variocon 2010
4 Pages
-
MiniCal® III
2 Pages
-
Micro IV Pump
2 Pages
-
9025-XPS
2 Pages
-
DS400
2 Pages
-
Microtector II G450
4 Pages
-
CS21
2 Pages
-
EC28
2 Pages
-
GMA313
2 Pages
-
GMA200-MGSS
2 Pages
-
Controller GMA200-MT
4 Pages
-
Controller GMA200-MW
4 Pages
-
G300 II / G300 III
2 Pages
-
Micro IV
4 Pages
-
Micro III
2 Pages