Transmitter EC28 DA

Transmitter EC28 DA

Transmitter EC28 DA

Product catalog summary
Overview: The EC28 DA Transmitter is designed for monitoring toxic gases, oxygen, or hydrogen in potentially explosive atmospheres. It features a display for current measured values and an alarm system, making it suitable for use in Ex zones. The device is ATEX-certified and complies with the European Functional Safety Standard DIN EN 61508-2: 2011.
Specifications: The transmitter operates with a 4 to 20 mA signal and includes Smart Sensor technology for easy sensor replacement. It has a 2.2-inch LC display, three control buttons, red alarm LEDs, and a 90 dB horn. The device ensures reliable measurement with minimal operating costs due to its long sensor life and low maintenance requirements.
Variants: The EC28 series includes several versions to meet different application needs, such as the basic EC28, EC28 D with display, EC28 DA with alarm features, and EC28 B with Modbus interface. Intrinsically safe versions are also available.
Technical Data: The transmitter uses an electrochemical measuring principle and supports diffusion or gassing per calibration adapter. It operates in temperatures from -20 to +50 °C in Ex zones and -25 to +50 °C outside Ex zones, with humidity levels of 5 to 90% r.h. It requires a power supply of 18 to 30 V DC and has a protection class of IP64.
Gas Detection and Safety Levels: The EC28 DA can detect various gases, including ammonia, chlorine, hydrogen chloride, carbon monoxide, and more, with safety integrity levels (SIL) up to SIL3 in single-channel or redundant use.
Certifications: The device is marked with II 2G Ex eb mb [ib] IIC T4 Gb, indicating its suitability for use in explosive atmospheres. It adheres to the functional safety standard DIN EN 61508-2: 2011.
Contact Information: GfG Gesellschaft für Gerätebau mbH, Klönnestraße 99, 44143 Dortmund, Germany. Phone: +49 231 56400-0, Email: [email protected].
See more

Catalog excerpts

Transmitter EC28 DA-1

Fixed gas detection systems With Display and Alarm for Use in Ex Zones

 Open the catalog to page 1
Transmitter EC28 DA-2

EC28 DA Transmitter With Display and Alarm for Use in Ex Zones Whenever toxic gases, oxygen or hydrogen are to be monitored and a display of the current measured value as well as an alarm is to be given on site, the EC28 DA transmitter combined with GfG's proven control units is the solution of choice. The ATEX-certified design means it can be used even in potentially explosive atmospheres. The hardware of the EC28 DA complies with the European Functional Safety Standard DIN EN 61508-2: 2011 for many gases. The SI levels (up to SIL3) in single-channel (1oo1) or redundant (1oo2) use are listed...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.