1. Catalogs
  2. gfai tech GmbH
  3. Acoustic Camera Star 48 AC PRO

Acoustic Camera Star 48 AC PRO

Acoustic Camera Star 48 AC PRO

Acoustic Camera Star 48 AC PRO

Product catalog summary
Overview: The Star48 is a large, preconfigured microphone array designed for outdoor acoustic measurements of large objects. It features a lightweight, foldable aluminum body for easy setup by one person and includes 48 interference-resistant microphone channels.
Specifications:
  • Microphone Channels: 48
  • Measurement Distance: 4 meters to several hundred meters
  • Camera: Baumer VCXG-25C with 1920 x 1080 resolution
  • Frequency Response: 20 Hz – 20 kHz (< 3 dB), 100 Hz – 15 kHz (< 0.5 dB), 20 kHz – 60 kHz (< 15 dB)
  • Max Sound Pressure Level: 130 dB peak at 3% THD
  • Noise Level: 27 dB(A)
  • Sensitivity: 20 mV/Pa
  • Array Diameter: 3.4 m
  • Weight: 7.4 kg
  • Operating Conditions: -15 °C to 55 °C, up to 80% RH, IP20 protection
  • Cable Length: Up to 20 m (50 m on request)
Applications:
  • Environmental noise control
  • Pass-by measurements of vehicles
  • Airplane fly-overs
  • Wind tunnel measurements
  • Low to mid-range acoustic frequency applications
Benefits:
  • Easy handling and accurate microphone positioning
  • Distinct array pattern aids troubleshooting
  • Slim aluminum body
  • Backward attenuation > -23 dB
Technical Data: The array supports acoustic mapping in the range of 12 dB to 130 dB with a recommended mapping frequency of 100 Hz to 13 kHz. It offers a dynamic range of 7 dB to 9 dB, extendable to 50 dB with advanced algorithms.
See more

Catalog excerpts

Acoustic Camera Star 48 AC PRO-1

Acoustic Camera Array Star48 AC Pro48 Channel System for Outdoor Measurements The microphone array Star48 is our largest preconfigured array and particularly suitable for outdoor measurements of large objects. The lightweight folding aluminum body of the array ensures a stable and safe setup by just one person. The array has 48 interference-resistant microphone channels. The recommended measurement distance ranges from four meters up to several hundered meters, depending on the spectral content of the measured acoustic signal and ambient conditions. Large objects can be measured and analyzed via time and frequency domain acoustic beamforming using the same methods as our smaller microphone arrays. Analysis can be performed quickly using NoiseImage software. ■ Easy handling and accurate microphone positioning ■ Distinct array pattern aids in troubleshooting even with non-ideal focus measurements ■ Slim aluminum array body ■ Environmental noise control ■ Pass-by measurements of vehicles ■ Wind tunnel measurements ■ Applications with low to mid-range acoustic frequency The Star48 features a Baumer VCXG-25C camera to provide ideal reference images for acoustic measurement tasks.

 Open the catalog to page 1
Acoustic Camera Star 48 AC PRO-2

TECHNICAL DATA Calculation of the lowest frequency (Hz) at 180° opening angle (DEG) * Distance to the source: 7 m; calculation points: 90.000 gfai tech GmbH

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.