Overview: This document provides specifications and applications for various models of thermostatic steam traps with membrane regulators, designed for different condensate flow rates and applications such as steam-tracing, drainage, and air-venting.
Specifications:
  • MK 45-1 and MK 35/31: Tandem seat for low condensate flow rates, suitable for steam-tracing, steam-line drainage, and air-venting.
  • MK 45-2 and MK 35/32: Single seat for medium condensate flow rates, used in steam-tracing and heat exchanger drainage.
  • MK 25/2 and MK 35/2 S: Single seat for large condensate flow rates, primarily for heat exchanger drainage.
  • MK 36/51 and MK 36/52: Tandem seat with flat gasket for a range of flow rates, suitable for food, biological, and pharmaceutical applications.
  • MK 45 A-1 and MK 45 A-2: For small and large condensate flow rates, used in steam-tracing and air-venting.
Key Features:
  • Very sensitive response characteristic and not impaired by high back pressure.
  • Automatic air-venting capability, suitable for thermal air-venting in steam systems.
  • Installation flexibility in both horizontal and vertical lines.
  • High hot-water capacities even with low differential pressures.
  • Stainless steel internals with a corrugated membrane made of Hastelloy.
  • Optional integrated condensate monitoring for MK 45 models.
Pressure/Temperature Ratings:
  • MK 35/31 and MK 35/32: Max pressure 18.6 bar at 225°C, 14.4 bar at 400°C.
  • MK 45-1 and MK 45-2: Max pressure 28.4 bar at 250°C, 23.1 bar at 400°C.
  • MK 36/51 and MK 36/52: Max pressure 32 bar at 240°C.
  • MK 45 A-1 and MK 45 A-2: Max pressure 29.3 bar at 200°C, 24 bar at 400°C.
Connection Types and Dimensions:
  • Available in flanged, screwed sockets, socket-weld, and butt-weld connections.
  • Overall lengths vary by model and connection type, with specific dimensions provided for each.
Capacity Charts: The document includes charts showing maximum hot condensate capacities for various models, indicating their performance under different conditions.
See more

Catalog excerpts

Thermostatic Steam Traps MK with Membrane Regulator-1

֕ Very sensitive response characteristic Function is not impaired by high back pressureՕ Automatic air-venting (trap can be used for thermal air-venting in steam systems) Installation in any position (horizontal and vertical lines)Օ High hot-water capacities even with low differential pressures With tandem seat (double sealing) for low condensate flowratesՕ Built-in non-return valve Stainless steel internals (corrugated membrane of Hastelloy)Օ Design UӔ with undercooling capsule: utilization of a certain amount of sensible heat by banking-up of condensate, decreasing the amount of flash steam Optional extra: Integrated condensate monitoring for MK 45 (temperature or steam loss) L MK 45-1 DN 15, 20, 25 TypeDesign/ApplicationMK 45-1MK 35/31 > 1 )With tandem seat (double sealing) For low condensate flowrates, steam-tracing, steam-line drainage, air-venting MK 45-2MK 35/32 > 1 )With single seat For medium condensate flowrates, steam-tracing, drainage of heat exchangers, air-venting MK 25/2 > 1 ) MK 25/2 S > 1 1 ) MK 35/2 S ) MK 35/2 S3 For large condensate flowrates, drainage of heat exchangers > 1 )With single seat MK 36/51 > 1 )MK 36/52 > 1 )With tandem seat (double sealing) Ֆ with flat gasket For small/large condensate flowrates, steam tracing, steam-line drainage, venting and vacuum-breaking. Also suitable for food, biological and pharmaceutical applications. > STAINLESS STEEL MK 45 A-1MK 45 A-2 For small and large condensate flowrates; steam-tracing,steam-line drainage, air-venting > L MK 35/31, DN 10, 15 STAINLESS STEEL 1 ) Can also be used for vacuum breaking (aerating). > Steam Trap for Thermostatic Air-Venting with Membrane Regulator The thermostatic steam traps with membrane regulators of the MK series can also be used for air-venting. Application Thermostatic steam trap for automatic air-venting and discharge of non-condensable gases and steam/air mixtures from steam lines and heat exchangers .A special type of membrane might be required. > 1 ) A 182 F316L > 1 ) 29.3 bar / 200аC 24 bar / 400C MK 45 A-2 PN 40 22 1.4404 > 1 ) A 182 F316L > 1 ) 29.3 bar / 200аC 24 bar / 400C > 1 ) Material complies with EN and ASTM requirements. > 2 ) MK 25/2 S DN 40/50: cover made of cast steel GS-C 25 (ASTM nearest equivalent: A 216 Gr. WCB) > 3 ) Physical and chemical properties comply with EN grade. ASTM nearest equivalent grade is stated for guidance only. > L 4 ) EN nearest equivalent grade is stated for guidance only. > * ) For more information see data sheet. >

 Open the catalog to page 1
Thermostatic Steam Traps MK with Membrane Regulator-2

3 )֖150֖֖Hinged clamp 65 65 6565֖ > MK 25/2 S, DN 40, 50 1 ) MK 45 with ASME flanges: overall length 172 mm available on request. > 2 ) Only MK 45 > 3 ) Made of carbon steel or > L L L stainless steel > MK 36/51, DN 8, 10, 15, 20 mm Connection: screwed socketMK 36/51, DN 8, 10, 15, 20 mm Connection: hinged clampMK 36/51, DN 15 mm Design with union butt-weld nipples The charts show the maximum hot condensate capacities. MK 45-1 (Curve 1) MK 35/31 (Curve 1) MK 25/2 S, DN 40, 50 (Curve 1) MK 35/2 S3, DN 25 (Curve 3) MK 45-2 (Curve 2) MK 35/32 (Curve 2) MK 25/2, DN 40, 50 (Curve 2) MK 35/2S, DN 25...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.