Catalog excerpts
FLOWSERVE GESTRA Equipment for Energy Supply Centres SPECTORmodule for Land and Marine Applications
Open the catalog to page 1Equipment for Energy Supply Centres Steam and condensate systems with one-stop sophistication Content Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Electrical pressure control Process steam Steam drier/ purifier Electrical temperature control Flash steam/gas Mechanical temperature control Energy supply centre Controlled from the condensate side Steam flow measurement Heat exchanger At a Glance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 GESTRA Steam Boiler Equipment – SPECTORmodule – For operation...
Open the catalog to page 2Overview Safety, reliability, availability and economy have always enjoyed top priority in boiler operation . To an increasing extent, another aspect is being added for the plant operators: process automation and visualization . To meet these stringent requirements, GESTRA AG has – for more than ve decades now – been working exclusively with electrode systems that are low in maintenance and wear; in contrast to other systems, they function entirely without moving parts, which leads to high service lifetimes and very low failure rates . By now, these GESTRA electrode systems are being...
Open the catalog to page 3Equipment for Energy Supply Centres At a Glance Conductive level control and signalling of limit levels Limiter systems with type approval and SIL 3 certification Level limiter High-level alarm Temperature limiter Supply voltage Response sensitivity Response sensitivity Level limiter Actual value Capacitive level control and signalling of limit levels SPECTORmodule SPECTORmodule Touch Input switchable – active Input switchable – passive Options: Actual value 4–20 mA Conductivity switch/controller Temperature monitor SPECTORmodule LRS 1-50 Input - Passive - Active Function Max Valve open/...
Open the catalog to page 4GESTRA Steam Boiler Equipment – SPECTORmodule – Level control with high-level alarm: level electrode NRG 16-36 (as controller), level switch NRS 1-54 Water level gauge For operation with limited supervision, e.g. as per TRD 602 (2 h) Low-level limiter of “high-integrity design”: level electrode NRG 16-50, NRG 16-36, level switch NRS 1-50, SIL 3 Conductivity measurement and continuous/intermittent blowdown: conductivity electrode LRGT 16-2, continuous blowdown controller LRR 1-51, continuous blowdown valve BAE; cycling timer TA, intermittent blowdown valve MPA Measuring point Pressure gauge...
Open the catalog to page 5Equipment for Energy Supply Centres GESTRA Steam Boiler Equipment – SPECTORmodule – For operation without constant supervision as per EN 12953 (72 h) Low-level limiter of “high-integrity design”: level electrode NRG 16-50, level switch NRS 1-50, SIL 3 Separate high-level alarm of “high-integrity design”: level electrode NRG 16-51, level switch NRS 1-51, SIL 3 Level control with high-level alarm and remote water level indicator: level probe NRG 26-21, level controller NRR 2-52, control terminal and display unit URB 50 und control valve V 725 Water level gauge Conductivity measurement with...
Open the catalog to page 6GESTRA Equipment for Steam Generators – Marine Boilers – Technical Information Equipment with maritime approvals GESTRA Equipment for Steam Generators – Marine Boilers – By making just a few technical modications, we were able to adapt our well-proven boiler equipment to the special requirements (as regards vibration, air conditioning, EMC etc .) of various classication societies . We can provide our customers with a large number of acceptance inspections – such as GL, LR, See-BG, RINA, NKK, ABS, KR, BV and DNV – which guarantee that the GESTRA equipment range meets the requirements of the...
Open the catalog to page 7Equipment for Energy Supply Centres GESTRA Equipment for Pressurized Hot-Water Plants – Conventional – for high-pressure hot-water generation with separate pressurizing vessel Low-level limiter of “high-integrity design”: level electrode level switch NRS 1-50, SIL 3 Level control with high-level alarm and remote water level indicator: level probe NRG 16-52, switching controller NRS 1-54, NRS 1-52 (HW) Intermittent blowdown valve PA Safety temperature monitor/limiter: resistance thermometer TRG, temperature switch TRS 5-50, SIL 3 Measuring point Return temperature elevation: resistance...
Open the catalog to page 8Technical Information Low-Level Limiters (LW) up to PN 320 1 The limiters consist of a combination of level electrode and level switch . In general, a distinction must be made between units of “conventional design” and those of “high-integrity design” (i .e . with self-monitoring) . The corresponding applications for the units are dened in the technical rules and depend mainly on the hazard potential of the plant . The basis for units of “conventional design” is the maximum operating pressure of the boiler (PED 0 .5 bar, TRD 701 1 bar) . The self-monitoring limiters of “high-integrity...
Open the catalog to page 9Equipment for Energy Supply Centres Technical Information On/Off Level Controllers/ Limit Switches with Fixed Switchpoints – Conductive Measurement – 3 SPECTORmodule Depending on the parameters of boiler capacity, required steam quality, plant economy and degree of automation, the make-up arrangement is differentiated into the on/off and modulating control modes . Within the on/off controls, these are subdivided further into those with xed switchpoints and those with continuously adjustable switchpoints . Besides make-up, these systems are also used for the simple signalling of limits, e .g...
Open the catalog to page 10Technical Information On/Off Level Controllers with Variable Switchpoints / Limit Switches or Modulating Level Control – Capacitive Measurement – 3 SPECTORmodule Using limit switches with variable switchpoints opens up the possibility of adapting on/off controls or limit values to changing operating conditions while the system is in operation . This is feasible because the capacitive measurement by the probe supplies a signal to the electronic control units that is proportional to the level; the desired switchpoint can therefore be set at the level switches . This measurement also makes it...
Open the catalog to page 11All GESTRA AG catalogs and technical brochures
-
STEAM-TRAP-MONITORING
2 Pages
-
BAE46-47
2 Pages
-
BK35A7-MK35A7-DK36A7
2 Pages
-
VKP40PLUS
2 Pages
-
MPA46
2 Pages
-
HERZLICH-WILLKOMMEN
2 Pages
-
GESTRA-INFORMS-UNA45-46-46A
2 Pages
-
STEAMTRAPS-BROCHURE
24 Pages
-
ZK-FLYER
7 Pages
-
FLYER-SPECTORMODUL
2 Pages
-
FLYER-NRGS15-1-LRGS15-1
2 Pages
-
CONTROL-VALVES-ZK
26 Pages
-
CHECK-VALVES
28 Pages
-
Thermodynamic Steam Traps DK
2 Pages
-
NAF
2 Pages
-
UNA
5 Pages
-
Control Valves ZK
4 Pages
-
Ball-Float Traps UNA
5 Pages