Features of the CW Series:
  • Direct acting proportional controller for regulating cooling-water return temperature.
  • Reduced capital costs and energy consumption due to higher discharge temperatures.
  • Prevents short-circuiting and automatically balances large systems.
  • Straight-through body with solid-state expansion thermostat and setting device.
  • Standard valve type CW 41 includes a pressure gauge (0–6 bar) and thermometer (–30 to +100 °C).
  • MCW 41 is CW 41 with a diaphragm actuator, retrofitting possible.
Applications:
  • CW 41: Industrial cooling water.
  • CW 41/4: Saline fluids, ammoniacal cooling water, and chlorinated hydrocarbons.
  • CW 44: General cooling water control.
  • CW 44 k: Wetted internal parts made from stainless steel.
  • MCW 41: Heavily contaminated cooling systems.
Specifications:
  • Type CW 41 and CW 41/4: Pressure rating of 16 bar, temperature range from –32 °C to 110 °C.
  • Type CW 44 and CW 44 k: Pressure rating of 25 bar, temperature range from –37 °C to 110 °C.
  • Temperature ratings depend on thermostat type: standard (110 °C), wax (100 °C), brine (85 °C).
Temperature Ratings:
  • MCW 41: Various thermostat and cone combinations with adjustment ranges from –37 °C to 106 °C.
Flowrates and End Connections:
  • Flowrates (Kvs values) vary by type and size, with CW 41 ranging from 2.1 to 98 m3/h.
  • End connections include flanged DIN PN 16 and screwed sockets, with overall lengths specified for each type and size.
See more

Catalog excerpts

Cooling Water Control Valves CW-1

L CW 44 CW 41 for industrial cooling water CW 44 CW 41/4 > L for saline fluids, ammoniacal cooling water and chlorinated hydrocarbons CW 44k (wetted internal parts made from stainless steel) MCW 41 for heavily contaminated cooling systems > PMX Material Pressure/Temperature [bar] EN ASTM PMA / TMA PMA / TMACW 41 16 6 EN-JS 1049 > 1 ) 16 bar/֖32C 16 bar/110аC > 2 ) > 3 ) CW 41/4 16 6 EN-JS 1049 > 1 ) 16 bar/֖32C 16 bar/110аC > 2 ) > 3 ) CW 44 25 16 1.0460 A 105 > 1 ) 25 bar/2ְC 25 bar/110C > 2 ) > 3 ) CW 44k 25 16 1.0460 A 105 > 1 ) 25 bar/Ж37C 25 bar/85аC > 2 ) > 3 ) > 1 ) ASTM nearest equivalent grade is stated for guidance only. Physical and chemical properties comply with EN. > CW 41 2 ) Temperature only admissible for a short time > 3 ) Admissible temperature depends on type of thermostat: type n (standard) 110 C, type w (wax) 100 а C, type k (brine) 85 C*) For more information see data sheets. > Type Thermostat/cone combination Adjustment rangeCW 41 wr or ws 20аC 60ְC CW 41/4 nr or ns 3C Ж 100C kr or ks Ж32C Ж 74C CW 44 n Ж2C Ж 106C CW 44k k Ж37C Ж 71C w = wax thermostat n = standard thermostat k = thermostat for briner = reduced cone for small flowrates s = standard cone for large flowrates > MCW 41 size="-1">

 Open the catalog to page 1
Cooling Water Control Valves CW-2

Overall length L [mm] Type End connection DN 10 DN 15 DN 20 DN 25 DN 40 DN 50 DN 80 DN 100 > 3 / > 8 " > 1 / > 2 " > 3 / > 4 " 1" 1 > 1 / > 2 " 2" 3" 4" CW 41 Flanged DIN PN 16 ֖ 160 200 230 310 350 CW 41/4 Flanged DIN PN 16 ֖ ֖ 160 200 230 310 350 CW 44 Screwed sockets 95 95 95 95 ֖ ֖ CW 44k Screwed sockets 95 95 95 95 ֖ ֖ > Type Cone DN 25 DN 40, DN 50 DN 80, DN 100CW 41 > 3 r Kvs value [m /h] 2.1 6.5 20 CW 41/4 Kvo (Preset bleed flow) [m > 3 /h] 0.12 0.31 1.0 s Kvs value [m > 3 /h] 10.5 31 98 Kvo (Preset bleed flow) [m > 3 /h] 0.55 1.5 5.0 G > 3 / > 8 G > 1 / > 2 G > 3 / > 4 G 1CW 44 Kvs value...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.