CTS1
1 /1Page

CTS1

CTS1
1 /1Page

Catalog excerpts

CTS1-1

OBAL ANALYTICAL SOLUTION Cryo Trap System The CTS 1 is used for cryogenic trapping of analytes between the pre-column and the analytical column in a dual GC-oven sys- tem. When trapping has been completed, analytes are released from the trap using a highly accurate temperature program ensuring the best possible introduction to the analytical column for optimal analyte separation and detection limits. Analytes can be concentrated from multiple injections onto the pre-column and subsequently separated and determined in one run on the analytical column helping to achieve better limits of detection. System Configuration • compatible with Agilent® Technologies GC 6890 and 7890 • fitting for capillary columns with 1 mm outer diameter • used as a cryotrap for GERSTEL Multidimensional Column Thermostated Zones • 1 combined zone that can be cooled or heated, length 5 cm • 2 heated transfer lines each 24.5 cm long Cooling Option Temperature Programming • second ramp starts sattelite GC • hold time maximum 650 min for each hold temperature *) Dewar vessel with 1.0-2.0 bar operating pressure mandatory. GERSTEL GmbH & Co. KG, Germany [email protected] • www.gerstel.de [email protected] • www.gerstel.de • in combination with the GERSTEL MAESTRO software, inte- grated in the Agilent® Technologies ChemStation software or operated in stand-alone mode • only one method and one sequence table required for the complete system including GC/MS when integrated in the ChemStation software • hardware start signal for the 2nd GC-oven is provided by the CTS 1 ensuring optimal synchronization of the two GC-ovens Operating Conditions • relative humidity max. 50-60%, non-condensing Storage Conditions • relative humidity max. 50-60%, non-condensing • total length approx. 54 cm • distance between the GCs approx. 25 cm • outer diameter approx. 5.7 cm Cryo Trap Enrichment System The Cryo Trap Enrichment System CTE 1 consists of a CTS 1 and a pneumatic module that enables venting of the pre-column effluent combined with separate pneumatic control of the analytical column. Custom solutions for special performance requirements available upon request. [email protected] • www.gerstelus.com GERSTEL Brasil [email protected] • www.gerstel.com.br [email protected] • www.gerstel.co.jp [email protected] • www.g

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.