

Catalog excerpts

Motordamper GFD - ø80 mm to ø500 mm GEOVENT fast turning on / off damper GFD is specially designed for use in point extraction systems that require rapid opening and closing of the dampers at suction points. GFD is a close damper that can open 90° down to 1 second. Rotating speed can be set between 1 to 5 seconds (use ø315, ø400 or ø500 mm). This damper is also available with modulating motor for fume hoods and fume for accurate control of the air. The damper is available from ø80 mm to ø500 mm Actuators >> Technical data sheet Power supply: Power consumption: level Sound power Technical data Functional data Shaft coupling Wire dimenstions: Safety 1 m Cabel, >1 500 000 partial cycles (max. ±5°) Position indication Service life mechanical with pointer > 100 000 cycles (0°...95°...0°) 2 Nm III (safety extra-low voltage) IP 54 (cable downwards) Protection class Degree of protection EMC LVD RoHS Mode of operation Rated impulse voltage Control pollution degree Ambient temperature normal operation Storage temperature Ambient humidity CE (2014/30/EU) CE (2014/35/EU) CE (2011/65/EU) Typ 1 (EN 60730-1) 0,8 kV (EN 60730-1) 3 (EN 60730-1) -30°C...+50°C -30°C...+80°C 5...95% r.H., non condensing (EN 60730-1) maintenance free Ambient temperature: Maintenance Dimensions / Weight Ordering table Dimensions Protection class: Weight Sound level: Operating mode / Properties Mode switch with five positions at the housing: Mode switch 1: Rotary direction switch with five positionsVDC right 2-10 at the Through connecting the power supply to Mode BU+BN (1+2) and a reference signal Y to housing: 2: Rotary direction right 0-10 VDC BK (3) of (0)2...10 VDC, moves the actuator to its specified position. The actual damper 1: rotary direction right 2-10 VDC position 0...100% is a feedback signal U 3: daption - 2: rotary direction right 0-10 VDC A on GY (4) for example to share with other working range within 3: adaption actuators. 4: rotary direction left 0-10 VDC the mechanical end stops. 5: rotary direction left 2-10 VDC The actuator is overload-proof, requires no limit switches and automatically stops 4: Rotary direction left 0-10 VDC when the end stop is reached. A supply of direct current (VDC) is preferred. 5: Rotary direction left 2-10 VDC 2018-02-06 08:54:34 • Copyright by GRUNER AG • Subject to change in technology and Design Operating mode Direct mounting Simple direct mounting on the damper shaft with a clamp, supplied with an anti-rotation strap to prevent the actuator from rotating. Manual override Manual override is possible with the self-resetting pushbutton (the gearing latch remains disengaged as long as the pushbutton is pressed). Power supply 230 V / 24 V for GFD motordamper. Effect 25 VA
Open the catalog to page 1All Geovent catalogs and technical brochures
-
Channel duct
3 Pages
-
HVU Lite - High Vacuum
1 Pages
-
Geofilter - GFC
1 Pages
-
Grinding/Welding table
1 Pages
-
ATEX - Ductfan
1 Pages
-
Geofilter - GFH and GFH PLUS
3 Pages
-
GeoGo
2 Pages
-
Double exhaust trolley
1 Pages
-
CERA exhaust arm
1 Pages
-
Extension arm
2 Pages
-
ESA arm
4 Pages
-
GeoGo Mini
2 Pages
-
Geovent Filter Unit GFB2
4 Pages
-
HVU High Vacuum Unit
2 Pages
-
Hose Reels GTE and GTS
5 Pages
-
PERMA arm
6 Pages
-
ASA-4 arm
2 Pages
-
ASX Arm - ATEX
2 Pages
-
GeoFlex Exhaust
1 Pages
-
GeoFlex Exhaust 220
1 Pages
-
GeoFlex Kevlar
1 Pages
-
GeoFlex Exhaust HT-650
1 Pages
-
GeoFlex Exhaust HT-1100
1 Pages
-
GeoFlex Standard
1 Pages
-
GeoFlex Weld
1 Pages
-
GeoFlex PUR
1 Pages
-
GeoFlex High
1 Pages
-
Geofilter GFX2 - ATEX
3 Pages
-
Dustbox CFU-1000
2 Pages
-
GeoFilter Dust
1 Pages
-
GeoFilter GF4
2 Pages
-
GeoFlex Exhaust HT-450
1 Pages
-
Quick-Action couplings
1 Pages
-
MHF fan
4 Pages
-
Geofilter GFO XT
1 Pages
-
LEF 800 - 1000
2 Pages
-
Multibox III
2 Pages
-
Plastic fan
5 Pages
-
GeoFilter Oil
2 Pages
-
Geofilter GFO 315
2 Pages
-
Smoking cabin
2 Pages
-
Portable Fan PM-180
1 Pages
-
Geoflex Standard
1 Pages
-
Exhaust Nozzles
15 Pages
-
Mini arm
1 Pages
-
Glue-fumes extractor
2 Pages
-
Wing arm
2 Pages
-
ASA-3 Arm
2 Pages
-
Flexi arm
5 Pages
-
Compact arm
2 Pages
-
High Vacuum Units
1 Pages
-
Emergency vehicles
4 Pages
-
Geofilter GFB2 Tower
5 Pages
-
Accessories for arms
1 Pages
-
MSQ 200 fan
1 Pages
-
Air Handling Unit
7 Pages
-
PowerBox III
1 Pages
-
Power Smart II
1 Pages
-
EC-fans
12 Pages
Archived catalogs
-
4Fl Industri Brochurer
2 Pages
-
Welding table
1 Pages
-
LSFG-MSFG
6 Pages
-
MultiBox II
2 Pages
-
GFA Filter
4 Pages
-
Fully electroplated Fans
1 Pages
-
Portable Fan, type PM-180
1 Pages
-
Comfort arm
2 Pages