1. Catalogs
  2. GeoSIG Ltd
  3. VE-53 / VE 52 / VE 51 Short Period Seismometer

VE-53 / VE 52 / VE 51 Short Period Seismometer
1 /2Pages

VE-53 / VE 52 / VE 51 Short Period Seismometer

VE-53 / VE 52 / VE 51 Short Period Seismometer
1 /2Pages

Catalog excerpts

VE-53 / VE 52 / VE 51 Short Period Seismometer-1

VE-53 / VE 52 / VE 51 Short Period Seismometer Features  Sensitivity 1000 V/m/s differential  Bandwidth 1.1 s (0.9 Hz) to 89 Hz 8.0 s (0.125 Hz) to 160 Hz (BB version)  Dynamic Range > 125 dB (0.9 - 15 Hz) > 120 dB (0.9 - 30 Hz)  Robust mechanical design  Excellent temperature and aging stability  Low power consumption  Easy testing, low maintenance Outline The VE-5x is a triaxial short period seismometer designed The VE-5x is housed in a sealed cast aluminium housing. The housing incorporates a single bolt mounting system for seismic monitoring applications. with three levelling screws. The VE-5x seismometer is based on a state of the art geophone mass-spring system with electronic feedback. It The broaderband version, VE-53-BB, is suitable for is ideally suited for installation in vaults with low to moderate applications involving an extended frequency range. noise. Stainless steel or Ex-proof packaging optionsb are also VE-5x offers a remarkable stability under temperature available. fluctuations or against aging. In addition due to the The VE-5x seismometer is directly compatible with all innovative design of the unit no mass locking is required. GeoSIG solutions. Nominal frequency response of VE-53 Nominal frequency response of VE-53-BB Link to VE-53 sensor response files in the IRIS NRL lib

 Open the catalog to page 1
VE-53 / VE 52 / VE 51 Short Period Seismometer-2

General Characteristics Configurations: Power Supply Voltage: Consumption: Overvoltage Protection: Testing Test input: 9 to 18 VDC 59 mA typical, 88 mA max. @15 VDC All pins are protected Activated by applying a 12 VDC voltage to generate an output of a pulse with an amplitude of 50% of the full scale Full Scale Range: 20 mm/s (± 10 mm/s) nominal output Environment/Housing Housing Type: Sensor Element Type: Dynamic Range: Linearity: Cross Axis Sensitivity: Bandwidth: Damping: Full Scale Output: Measuring Range (see plot): Over damped geophones > 125 dB (1 - 15 Hz) > 120 dB (1 - 30 Hz) ± 0.05...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.